Please click here to check who's online and chat with them.

Find Verified Non Destructive Testing Suppliers, Manufacturers and Wholesalers

Sep-07-11
Supplier From Beijing, China
 
Non-destructive testing instruments.
Oct-14-21
 
Ultrasonic Pulse Velocity test,
Rebound Hammer test,
Cover Meter test,
Core Extraction and testing,
Half Cell Potentiometer test,
Carbonation test,
Chemical Analysis of Concrete,
Thickness Measurement,
Pile Integrity test,
Pull out test,
Load test,
Vibration Analysis,
Electrical Resistivity,
Tomography,
Seismic Refraction,
Block Vibration test,
Apr-10-18
Supplier From Changsha, Hunan, China
 
Each kind of test measurement such as Technical Properties (Flattening Test, Bending Test, Blow Test, Impact Test), Exterior Size Inspection, Hydrostatic Test, X-ray Test would be necessary for guarantee of the high quality of steel pipe like seamless steel pipe, galvanized steel pipe.

There are some characteristics for visual inspection of non-destructive testing:
1.Weld surface defects test: surface cracks would be the first step for check of the steel pipe and then the impermeability and weld quality of the leak.
2.Detailed exam for raw material for steel pipes production, such as the surface cracks, peeling, cables, scratches, dents, bumps, spots, corrosion and other defects.
3.Cavity detection. This test would carry out according to the engineering projects demand and the engineers requirement.
4. Additional material inspection. Inspect the product for dust, foreign matter and other residues in the cavity.
Oct-30-09
 
As per above

280 ml and 400ml
Jun-28-05
Supplier From Burbank, California, United States
117381 Non Destructive Testing Suppliers
Short on time? Let Non Destructive Testing sellers contact you.
Nov-25-21
Supplier From Ahmedabad, Gujarat, India
Jul-30-15
Supplier From Mumbai, Maharashtra, India
GOLD Member
Apr-02-22

Saliva Test Kit Painless Testing

$1.36
MOQ: 10000  Pieces
Sample Available
 
Saliva Test Kit Painless testing plastic disposable Ag Rapid Detection Kit
SILVER Member
Mar-10-22

Flow Flex Test Kits

$4
MOQ: Not Specified
 
A box 2 doses I HEALTH price $6+10%
A Box 1 dose Flow Flex Price $4.4 +10%
You can be seller mandate

DDP USA AND ALL OVER WORLD

ATTENTION PAYMENT SBLC or BCL /PB

Moq 500K
MAX 5-10MX12Month
DDP USA or World BY AIR
Buyer side 50% Commission open
You can be seller part 10% of 50% for you

SOP:

1, Documents NCNDA ICPO KYC
2 Seller FCO
3 DRAFT SPA DRFT SBLC OR BCL /PB
4 SPA sign &IMFPA
5 ATTENTION PAYMENT
SBLC/BCL /PB / TT
6,Can get Allocation letter after confirm payment
7 DDP buyer Port Inspection pay TT
8 Then keep rolling for next deal


Notice

1,You can Mark up
2 you can be seller part
3 DDP to your warehouse

2022 Feb 26-Mar 10
GOLD Member
Apr-02-22

Antibody Test Kits

$1.16
MOQ: 10000  Pieces
Sample Available
 
Antibody Test Kits Hot Sale Medical Diagnostic Antigen Antibody Rapid Test Kits
Feb-19-09
Supplier From Dandong, Liaoning, China
Jul-13-10
Supplier From Beijing, China
Feb-23-13
Supplier From Beijing, China
GOLD Member
Apr-02-22

Rapid Antigen Test Kit

$1.16
MOQ: 10000  Sets
Sample Available
 
SARS-CoV-2 Rapid Antigen Test kit
Colloidal Gold Method Medical
Simple Rapid
Convenient
Sensitivity : 98.4%
Specificity : 98.1%
Test Time : 10-15min
Feb-23-13
 
With different external probes, the gauge can be applied to measuring thickness of non-magnetic coating on magnetic metal substrate, as well as non-conductive coating on non-magnetic metal substrate.
Five types of probes (F400, F1, F10, N1, CN02) are available for different application. F10 probe measures up to 10mm.
Two measuring modes: single or continuous, changeable.
Two calibration methods can be applied to the gauge; And the system error of the probe can be corrected with the basic probe calibration method.
Measured values and user information are shown on a large, easy-to-read LCD. A display back light ensures easy reading of screen data in poorly-lit conditions.
Measuring status indicator showing the measuring status.
n.


Measuring Principles
The gauge adopts two thickness-measuring methods: magnetic induction method and eddy current method.
insulating coatings on all non-ferrous metals and on austenitic stainless steels, e.g. paint, anodizing coatings, ceramics, etc. applied on aluminum, copper, zinc die-casting, brass, etc.


Working Conditions
Working temperature£º -10¡æ¡«£«50¡æ;
Storage temperature£º-30¡æ¡«£«60¡æ;
Relative humidity: ¡Ü90£¥;
The surrounding environment should avoid of vibration, strong magnetic field, corrosive medium and heavy dust.
Configuration

No.
Item
Quantity
Remarks


Standard
Config.
1
Main unit
1

2
Probe
1
F1 or N1
3
Calibration Foils
5 PCS

4
Zero plate
1
Iron or Aluminum
5
Instrument case
1

6
Manual
1

7
Alkaline Battery
2 PCS
AA size
8



Optional
Config.
9
Other type of probes


10
DataPro software
1
On CD
11
USB cable
1

bjxhhd-tech.com sinharef@126.com
Feb-23-13
 
Capable of performing measurements on a wide range of material.
Four transducer models.
Probe-Zero function, Sound-Velocity-Calibration function.
Two-Point Calibration function.
Two work modes: Single point mode and Scan mode.
Coupling status indicator showing the coupling status.
Auto sleep and auto power off function to conserve battery life.
Optional software to process the memory data on the PC.
Optional thermal mini-printer to print the measured data via RS232 port


CONFIGURATION

No
Item
Quantity
Note
Standard Configuration
1
Main body
1

2
Transducer
1
Model: N05/90¡ã
3
Couplant Bottle
1

4
Instrument Case
1

5
Screwdriver
1

6
Alkaline battery
2
AA size
7
Operating Manual
1
8
Warranty Card
1

Optional Configuration
9
Transducer: N02

10
Transducer: N07

11
Transducer: HT5

12
Mini thermal printer
1

13
Print cable
1

14
DataPro for Thickness Gauge
1
For use on the PC
15
Communication Cable
1


APPENDIX A: TRANSDUCER SELECTION
Model

Freq


MHZ

Diam


mm
Measuring Range Lower limit Description
N02 2.5 14

3.0mm¡«300.0mm£¨In Steel£©
40mm (in Gray Cast Iron HT200)
20 for thick, highly attenuating, or highly scattering materials
N05 5 10 1.2mm¡«230.0mm£¨In Steel£© ¦µ20mm¡Á3.0mm Normal Measurement
N05/90¡ã
5 10 1.2mm¡«230.0mm£¨In Steel£© ¦µ20mm¡Á3.0mm Normal Measurement
N07 7 6

0.75mm¡«80.0mm
£¨In Steel£©
¦µ15mm¡Á2.0mm For thin pipe wall or small curvature pipe wall measurement
HT5 5 12 3¡«200mm £¨In Steel£© 30 For high temperature (lower than 300¡ãC) measurement.

APPENDIX B: SOUND VELOCITY IN DIFFERENT MATERIALS
Material
Sound Velocity
In/us
m/s
Aluminum
0.250
6340-6400
Steel, common
0.233
5920
Steel, stainless
0.226
5740
Brass
0.173
4399
Copper
0.186
4720
Iron
0.233
5930
Cast Iron
0.173-0.229
4400-5820
Lead
0.094
2400
Nylon
0.105
2680
Silver
0.142
3607
Gold
0.128
3251
Zinc
0.164
4170
Titanium
0.236
5990
Tin
0.117
2960
Epoxy resin
0.100
2540
Ice
0.157
3988
Nickel
0.222
5639
Plexiglass
0.106
2692
Polystyrene
0.092
2337
Porcelain
0.230
5842
PVC
0.094
2388
Quartz glass
0.222
5639
Rubber, vulcanized
0.091
2311
Teflon
0.056
1422
Water
0.058
1473


CONFIGURATION

No
Item
Quantity
Note
Standard Configuration
1
Main body
1

2
Transducer
1
Model: N05/90¡ã
3
Couplant Bottle
1

4
Instrument Case
1

5
Screwdriver
1

6
Alkaline battery
2
AA size
7
Operating Manual
1
8
Warranty Card
1

Optional Configuration
9
Transducer: N02

10
Transducer: N07

11
Transducer: HT5

12
Mini thermal printer
1

13
Print cable
1

14
DataPro for Thickness Gauge
1
For use on the PC
15
Communication Cable
1

bjxhhd-tech.com sinharef@126.com
Feb-23-13
 
With different external probes, the gauge can be applied to measuring thickness of non-magnetic coating on magnetic metal substrate, as well as non-conductive coating on non-magnetic metal substrate.
Five types of probes (F400, F1, F10, N1, CN02) are available for different application. F10 probe measures up to 10mm.
Two measuring modes: single or continuous, changeable.
Two calibration methods can be applied to the gauge; And the system error of the probe can be corrected with the basic probe calibration method.
Measured values and user information are shown on a large, easy-to-read LCD. A display back light ensures easy reading of screen data in poorly-lit conditions.
Measuring status indicator showing the measuring status.
The gauges¡¯ user-friendly measuring system permits automatic storage of up to 1000 readings in one memory matrix for later statistical evaluation.


Measuring Principles
The gauge adopts two thickness-measuring methods: magnetic induction method and eddy current method.
insulating coatings on all non-ferrous metals and on austenitic stainless steels, e.g. paint, anodizing coatings, ceramics, etc. applied on aluminum, copper, zinc die-casting, brass, etc.


Working Conditions
Working temperature£º -10¡æ¡«£«50¡æ;
Storage temperature£º-30¡æ¡«£«60¡æ;
Relative humidity: ¡Ü90£¥;
The surrounding environment should avoid of vibration, strong magnetic field, corrosive medium and heavy dust.
Configuration

No.
Item
Quantity
Remarks


Standard
Config.
1
Main unit
1

2
Probe
1
F1 or N1
3
Calibration Foils
5 PCS

4
Zero plate
1
Iron or Aluminum
5
Instrument case
1

6
Manual
1

7
Alkaline Battery
2 PCS
AA size
8



Optional
Config.
9
Other type of probes


10
DataPro software
1
On CD
11
USB cable
1
Feb-23-13
 
The model MT160 is a digital ultrasonic thickenss gauge. Based on the same operatinfg principles as SONAR, the instrument is capable of measuring the thickness of various materials with accuracy as high as 0.01 /0.1mm. It is suitable for a variety of metallice and non-metallic materials.
Capable of performing measurements on a wide range of material, including metals, plastic, ceramics, composites, epoxies, glass and other ultrasonic wave well-conductive materials.
Transducer models are available for special application, including for coarse grain material and high temperature applications.


CONFIGURATION

No
Item
Quantity
Note
Standard Configuration
1
Main body
1

2
Transducer
1
Model: N05/90¡ã
3
Couplant Bottle
1

4
Instrument Case
1

5
Alkaline battery
2
AA size
6
Operating Manual
1

7
Warranty Card
1
8



Optional Configuration
9
Transducer: N02

10
Transducer: N07

11
Transducer: HT5

12
Mini thermal printer
1

13
Print cable
1

14
DataPro for Thickness Gauge
1
For use on the PC
15
Communication Cable
1

bjxhhd-tech.com sinharef@126.com
Feb-20-09
 
[input]
Input voltage range: 220vac10%; frequency: 50hz2%; input power: 5kw

[output]
Output voltage range: 20kv-450kv; kv adjusting accuracy: 0.1kw; output current: 30ma;
Ma adjusting accuracy: 0.1ma; cycle of operation: continuous

[working environment]
Temperature: 5-50µ; humidity: 80%; air atmosphere: 70kpa-106kpa;
Dimension of controller: 50034680mm; dimension of high voltage generator: 8304761080mm
Feb-19-09
 
Specifications:
Model: xxg-1605; xxg-2005; xxg-2505; xxg-3005; xxg-3505
Output voltage(kv): 60~160; 100~200; 150~250; 170~300; 180~350
Input power (kw): 1.5; 2.0; 2.5; 3.0; 3.4
Focus size(mm): 0.8íß0.8; 2.0íß2.0; 2.0íß2.0; 2.5íß2.5; 2.5íß2.5
Beam angle: 40+5íp; 40+5íp; 40+5íp; 40+5íp; 40+5íp
Max. Penetration a3 steel (mm): 19; 30; 40; 50; 60
Generator weight(kg): 14.5; 18; 30.5; 36.5; 38

Wooden package
117381 Non Destructive Testing Suppliers
Short on time? Let Non Destructive Testing sellers contact you.