Please click here to check who's online and chat with them.

Find Verified Modbus Rtu To Fieldbus Ff Built In Module Suppliers, Manufacturers and Wholesalers

Nov-01-19
 
Product Overview
M0313 module makes it possible to convert Modbus RTU protocol directly to FF H1 protocol. Using M0313 module, the difficulty of development can be reduced and the upgrade of Modbus RTU device can be easily achieved. Only by simply configuration, the users can realize conversion from Modbus RTU protocol to FF protocol. M0313 module is provided with two LED indicating lights, used to indicate the current working status.
Features
Support 1 Modbus RTU slave device
1 RES function block complying to FF specification
1 Modbus transducer block
4 PID function blocks complying to FF specification
4 for each AI,AO,DI,DO function block complying to FF specification, each function block supports 8 channels
Modbus RTU device upgrading
LED working status indicator
GOLD Member
Feb-25-23

All-In-One Energy Storage Solar System 3Kw

$1.00K
MOQ: 30  Pieces
Sample Available
 
The HBP1800 series all-in-one energy storage solution, support 1KW 2KW 3KW output for different load appliances. It's based on the original cabinet design, stacked with solar energy storage lithium battery 960wh~3072wh, and built in battery protection system, fully retain the use of load power in applications of residential, school, commercial and public utility area.
Features higher capacities for greater compatibility with more power-hungry devices, and the latest in USB-C Power Delivery capable of charging larger USB devices like laptops.
Includes pre-installed solar charging optimization module that functions as a maximum power point tracker (MPPT), resulting in up to 40% faster charge times.
With LiFePO4 lithium cells, known for stability and safety, monitored by a state-of-the-art battery management system that prevents overcharge, over-current, and short circuiting.
Built in Multi safety protection that include short circuit, overload and over-temperture and error code reporting.
GOLD Member
Feb-25-23

All-In-One Energy Storage Solar System 1Kw

$536
MOQ: 30  Pieces
Sample Available
 
The HBP1800 series all-in-one energy storage solution, support 1KW 2KW 3KW output for different load appliances. It's based on the original cabinet design, stacked with solar energy storage lithium battery 960wh~3072wh, and built in battery protection system, fully retain the use of load power in applications of residential, school, commercial and public utility area.
Features higher capacities for greater compatibility with more power-hungry devices, and the latest in USB-C Power Delivery capable of charging larger USB devices like laptops.
Includes pre-installed solar charging optimization module that functions as a maximum power point tracker (MPPT), resulting in up to 40% faster charge times.
With LiFePO4 lithium cells, known for stability and safety, monitored by a state-of-the-art battery management system that prevents overcharge, over-current, and short circuiting.
Built in Multi safety protection that include short circuit, overload and over-temperture and error code reporting.
Nov-01-19
 
Product Overview

M0310 module makes it possible to convert Modbus RTU protocol directly to HART protocol. Using M0310 module, the difficulty of development can be reduced and the upgrade of Modbus RTU device can be easily achieved. Only by simply configuration, the users can realize conversion from Modbus RTU protocol to HART protocol. M0310 module is provided with two LED indicating lights, used to indicate the current working status.





Features

Comply with HART PROTOCOL standard V7.0
HART slave station and Modbus master station form
Support 1 Modbus RTU slave device
Support 6 device variables,4 dynamic variables
Configured by HART interface
Write-protection of users data
Support high/low current transfinite alarm
TTL Modbus interface
LED power and communication indicator
Nov-01-19
 
Modbus-DP built-in module realizes the connection from Modbus RTU device to PROFIBUS DP network .It realizes the conversion function from MODBUS Protocol to PROFIBUS DP Protocol. Only by simply operating Modbus configuration tool, the users can realize connection from Modbus RTU device to PROFIBUS DP network.

M0306 module works with DIP16 2.54mm standard interface, 3.3 V power supply, Modbus communication indicating light to quick diagnosis the device status. It uses simple convenience

Combining with the features of high reliability and high flexibility, M0306 module is an ideal choice for user to develop OEM devices with PROFIBUS DP protocol.
1012 Modbus Rtu To Fieldbus Ff Built In Module Suppliers
Short on time? Let Modbus Rtu To Fieldbus Ff Built In Module sellers contact you.
GOLD Member
Feb-06-23
Supplier From Dhaka, Dhaka, Bangladesh
 
The NFS-3030 is a fire alarm control panel (FACP) manufactured by Notifier. It is designed for use in small to medium-sized fire protection systems and provides effective fire detection and alarm notification. The NFS-3030 features a compact design and advanced microprocessor technology, making it easy to install and program. The control panel supports up to 384 points and includes built-in communication options, such as analog dialer and network interfaces, for remote access and system integration. It is compatible with a range of Notifier fire detectors, modules, and accessories, providing versatility and customization for specific fire protection needs. The NFS-3030 is a cost-effective and reliable fire alarm control panel from Notifier.
GOLD Member
Feb-06-23
Supplier From Dhaka, Dhaka, Bangladesh
 
The NFS2-640 is a fire alarm control panel (FACP) manufactured by Notifier. It is designed for use in medium to large-scale fire protection systems and provides reliable fire detection and alarm notification. The NFS2-640 features a compact design and advanced microprocessor technology, allowing for easy installation and programming. The control panel supports up to 640 points and includes built-in networking capabilities for remote access and system integration. It is compatible with a range of Notifier fire detectors, modules, and accessories, offering flexibility and customization for specific fire protection needs. The NFS2-640 is a feature-rich and reliable fire alarm control panel from Notifier.
Mar-25-21
 
The M160T Ethernet Remote I/O module provides 8 optical-isolated digital inputs, supports max. 10Mhz high speed pulse counter, 8 isolated 12bits analog inputs, supports 0~5V, 0~10V, 4~20mA, 0~20mA analog signal, 8 digital outputs, supports 10Hz~300Khz high speed pulse output or relay outputs. All of the I/O with high sampling frequency and special filtering strategy to ensure its reliable. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.
GOLD Member
Jun-20-25

Electric Actuator, stainless steel, cast iron, mild steel

$1 - $5.00K / Piece (FOB)
MOQ: 1  Pieces
Sample Available
Supplier From Ahmedabad, Gujrat, India
 
Accurate Electrical Electric Actuators are engineered for reliable and precise control of valves and industrial automation systems. Built with a compact design and durable materials, these actuators deliver consistent torque output and smooth operation in demanding environments. Suitable for on/off and modulating duty, our actuators are available in various torque ratings and mounting configurations, ensuring compatibility with different valve types. Key features include IP-rated enclosures, high-efficiency motors, and manual override options for safety. Ideal for HVAC, water treatment, oil & gas, and manufacturing applications.
May-20-17
 
Clients can order online from our website.
Wj102-232/485-rj45 : multifunctional serial server module
Two years warranty, ce approved
Product features:
>>modbus rtu protocol automatically converted into mobus tcp protocol
>>100m high-speed lan, 10 / 100m adaptive ethernet interface
>>support auto mdi / mdix, you can use a crossover cable or parallel cable connection
>>rs232 baud rate can be set from 300-256000
>>working mode selectable tcp server, tcp client,
Udp mode, udp server mode
>>supports virtual port mode
>>across the gateway, across switches, routers
>>can work in lan, you can also work on the internet (extranet)
>>working port, destination ip address and port can be easily set
>>flexible serial data sub-frame is set to meet user demand for subcontracting
Product overview:
Wayjun wj102-232/485-rj45 is a industrial protocol converter between rs232/485 and tcp/ip. This server uses the tcp port network packets or udp packets and rs232 or rs485 interface data to achieve transparent transmission, achieve transmission, serial servers so that you can easily connect serial devices to ethernet and internet, network management of serial devices. And compared to similar products, its distinguishing feature is the stability of full-duplex, non-stop sending large amounts of data without losing a byte.
Nov-01-19
 
Product Overview

G1003 gateway realizes protocol converting from HART to Modbus RTU / ASCII. Supporting to connect multi HART slave devices into Modbus network. In the gateway, HART terminal is master station, Modbus terminal is slave station.



Features

Be tallied with HART7.0
HART master and Modbus slave mode
4~20mA analog signal overlay HART digital signal
Support 15 HART slave device
Configure gateway by special software
Write protect user data
RS485 Modbus interface
LED power and communication indicating
Standard DIN rail installation
Mar-13-23
 
The battery is a new type of energy storage product, which can be used to provide reliable power supply for various equipment and systems.

It is especially suitable for applications with large power, limited installation space, limited bearing capacity and long life.Battery built-in bms battery management system, battery voltage, current, temperature and other information management and monitoring.

In addition, the battery pack can balance the charge and discharge of the battery to prolong the cycle life. Multiple battery packs can be parallel to expand capacity and power, parallel to expand capacity and longer power support time requirements.
1.Environmental protection and pollution-free: the whole module using materials are non-toxic, pollution-free;

2.long safety life: the core cathode material of battery module is made of LiFeOP4, good safety performance and long service life;
3.Protection function: battery management system can protect battery module over discharge, over charge, over current and high / low temperature;
4.Equilibrium function: the battery management system has its own passive equalization, can balance the battery module each single string core;
5.Expansion: flexible configuration, multiple battery modules can be parallel expansion capacity, applicable to different standby time requirements;
6.Low power consumption: the battery has the function of automatic dormancy, when no live equipment is connected, it can enter the low power state by itself and reduce the self-loss;
7.No memory: no memory effect, shallow charge and discharge performance is excellent;
8.Wide temperature range: working temperature range-20~70, charge 0~60, discharge-20~70, good discharge performance and cycle life,


Built in BMS overall protection
1.Over charged protection
2.Over discharged protection
3.Thermal protection
4.Over current protection
5.Cell balancing
Nov-01-19
 
Provide FF H1 communication ability to Modbus device

Support standard DD or EDD specification (FF H1)

Electrical interface connected with Modbus device

supports TTL level, RS485 and RS232



G0313 Modbus to FF Gateway is a gateway device of Modbus protocol and FF protocol developed by Microcyber. As Modbus master station, G0313 Modbus to FF Gateway communicates with Modbus-RTU device via RS485 interface, and it can convert the data of Modbus-RTU device to FF device variable output.

G0313 Modbus to FF Gateway size is 99Ã?22.5Ã?114.5mm, and supports standard DIN rail installation.



There is a 3-bit DIP switch for G0313 Modbus to FF Gateway, shown as the following Figure.

SIM: Simulation switch, used for simulation function.

WP: Write protection, all the write operation for FF smart pressure transmitter shall be refused, which avoid data modification at random.



RST: Reset, reset device date to factory original. Power off the device at first, and made the switch at ON, and then power on the device, the device shall be reset to factory original.
Modbus to FF gateway is a gateway device supporting Modbus and FF protocol. As FF device, it can communicate with Modbus devices, read Modbus data to FF device by simply configuration, and transfer data to control system through FF bus.
Modbus to FF Gateway supports 4 Modbus slave devices, 8 groups of analog input output and discrete input output parameters, totally 32 channels provided. It configures Modbus devices data into transducer blocks parameters via Modbus register, and provides data support for FF system via channels between variables and AI, AO, DI and DO function blocks.
Nov-01-19

Modbus To Profibus Pa Module

$200
MOQ: Not Specified
 
Physical Parameters

Bus signal: compliant with IEC61158-2 physical layer standard

Bus power supply: 9 ~ 32V

Operating temperature: -40 ~ 85°C

Static current: â?¤14mA

Humidity range: 5% ~ 95%,non-dew

Mechanism size: diameter 66mm(can be customized)



Supportive MODBUS Communication Parameters

Address: 1 ~ 255

Baud rate: 9600 / 19200 / 15625 / 31250 /62500 / 125000 bps

Data bit: 7 / 8 bits

Calibration: odd / even calibration

Stop bit: 1 / 2 bits

CRC calibration: low byte ahead / high byte ahead

Data format: support various data formats



Supportive MODBUS Function Code

Function Code 1: read loop status

Function Code 2: read discrete input status

Function Code 3: read keeping register value

Function Code 4: read input register value

Function Code 6: write loop

Function Code 16:write multiple register values
Jul-13-23
 
S275 is a 4G RTU with IIoT data acquisition remote monitoring and control SMS alarm functions it is widely used in remote data acquisition and monitoring of various industries such as smart grid smart transportation industrial automation smart building firefighting public safety environmental protection meteorology digital medical agriculture forestry water coal mining petrochemical and other fields

8 digital input 4 relay output 6 analog input and 1 temperaturehumidity input
1 RS485 serial port Modbus RTU MasterSlave can expand multiple Modbus Slave devices Max 320 data points
Embedded TCPIP stack supporting Modbus RTU Modbus TCP and transparent transmission
Builtin powerful telephone and SMS alarm function regular reporting abnormal upper and lower limit alarm
Local logic control of the device linking relay outputs based on monitoring of digital input and analog value thresholds
Antidropout mechanism to ensure the device always online and it comes with data retransmission function
Support remote configuration remote management and remote restart by SMS
Builtin powerful timer function support timed automatic reporting timed daily SMS timed online timed offline timed restart timed execution relay output etc
Oct-09-23

Rtu Modbus Gprs Gateway

$120
MOQ: Not Specified
Supplier From Chennai, Tamil Nadu, India
 
With the support of diligent team of professionals, R S Enterprises is known as a leading manufacturer, supplier, exporter and trader of Water Purifier Plant, Water Softener, RO System Spare Part, Solar Lamp, Water Demineralizer, Solar Panel and many more. We also render highly reliable and effective RO System Installation Service to the customers. We have started our business in the year 2010 as a partnership based company at Chennai in Tamil Nadu, India. Our products are highly appreciated among the customers for their high reliability, advance technology, hassle free performance, excellent finishing, less maintenance requirement, long service life and various other features. Moreover, we use high grade inputs, advance technology and innovative ideas of our skilled technician in the manufacturing of these products. Our dedicated team of skilled professionals enables us to deliver the bulk consignments of customers on time with maintaining world class standards in our products. Our exporting countries are East Asia, North Asia, South Asia, Germany and Indian Subcontinent.
Oct-06-23

Modbus Rtu Gprs Gateway

$150
MOQ: Not Specified
Supplier From Chennai, Tamil Nadu, India
 
Item Code: WCT-805BOur Commapany offers (No AT Commands) Serial/Modbus/RTU to GPRS Gateway communication link provide a cost economical approach to achieve â??alwaysONâ?? packetized data network. It is a plug and play device, allows you the migration of your traditional serial communication system to the advance GPRS link, without tedious application development and in depth knowledge of AT command or GPRS. You can view this device as the virtual serial wire over the air that links all your remote equipments to the central PC. It is a full transparent, protocol independent gateway, for AMR, SCADA, general remote monitoring, control and data exchange applications.

Features:
Automatic Meter Reading
Power Monitoring and Control
Fault Indicators
Temperature Alerts, Indicators
Pump Control, Flow Measurements
Surveillance
Home Automation
Windmill, SCADA, Data Exchange
Central Monitoring and Control Systems
Base Station, ATM Monitoring and Control


Other information:
Easy to plug and play allows to migrating your traditional serial communication system to the advance GPRS link, without tedious application development and in depth knowledge on AT command or GPRS. You can view the device like virtual serial wire over the air that links all your remote equipments to the central PC/Server. It is a full transparent protocol in-dependent gateway. It is easy to configure, manage, and monitor remote devices on a private network over the Internet. The products also come with built-in I/O that can be configured to indicate the priority of events. The device can configured or update firmware over the air (OTA).
Nov-30-18

Gcan-204 Modbus Rtu

$130
MOQ: Not Specified
Supplier From Shengyang, Liaoning, China
 
Introduction : The GCAN-204 module is a CAN-Bus converter, used for serial and CAN-Bus connection. It is an industrial-grade CAN-Bus converter, whose function is to realize bidirectional conversion between CAN-Bus and serial Bus of Modbus RTU protocol.
Features : 1.Support CAN2.0A and CAN2.0B, conform to ISO/DIS11898 ; 2.Modbus slave station support function code: 03H, 04H, 06H, 16H. Parameters : 1.RS485 interface adapts two-lines connection, RS485, CAN interface use terminal connection ; 2.Use professional configuration software to set working mode and all parameters ; 3.Save configured parameters in storage, call the latest parameters automatically after supplying power ; 4. Install on the DIN rail ; 5.Support CAN-Bus communication baud rate: 5Kbps~1Mbps ; 6. Support serial interface baud rate: 600bps~115200bps ; 7.Electric isolation, insulation level: DC1500V ; 8. Receive maximum data flow: 400 FPS ; 9. Voltage: 9~30V DC power supply( DC24V) ; 10. Current: 20mA ; 11. Working temperature: -40~ 85 ; 12. Size: 113 * 100 * 21mm
VERIFIED
Feb-16-22
 
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic.
Functional details
1. Hot plug
Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system.
2. Advanced current sharing technology
Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A.
3. Control of input limited power
Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode.
4. Control of output constant power
When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module.
The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V.
The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage.
5. Temperature limited power
6. Regulation of output current limiting point
8. Regulation of output voltage
The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc.
9. Fan control
The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module.
10. Protection of input overvoltage/ voltage shortage
11. Output overvoltage protection
The overvoltage protection point is 260Vdc ~770Vdc ( +10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection.
12. Over-temperature protection
The environmental over-temperature protection point is 80 C. When the DC panel has a temperature over 100 C, the module will stop working; when the DC panel has a temperature below 90 C, the module will automatically work again.
13. Protection of internal bus fault
When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on.
14. Short circuit protection
In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
VERIFIED
Feb-17-22
 
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic.
Functional details
1. Hot plug
Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system.
2. Advanced current sharing technology
Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A.
3. Control of input limited power
Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode.
4. Control of output constant power
When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module.
The SD75200 module uses two operating modes with output voltage ranges of 50 to 750V.
The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage.
5. Temperature limited power
6. Regulation of output current limiting point
8. Regulation of output voltage
The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc.
9. Fan control
The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module.
10. Protection of input overvoltage/ voltage shortage
11. Output overvoltage protection
The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection.
12. Over-temperature protection
The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again.
13. Protection of internal bus fault
When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on.
14. Short circuit protection
In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
1012 Modbus Rtu To Fieldbus Ff Built In Module Suppliers
Short on time? Let Modbus Rtu To Fieldbus Ff Built In Module sellers contact you.
Explore Modbus Rtu To Fieldbus Ff Built In Module related import export discussions