The Discover Drug Test Cassette is a fast visual, competitive panel immunoassay that can be used for the qualitative detection of drug metabolites at specific cutoff levels in human saliva.
Up to 99% Accurate
Immediate Results
Shelf-life up to 18 months
Collect the specimen with collector
Add 3 drops to the well
Read the results immediately
Ideal for low-volume donations
These are screening devices only and although very accurate if you get a positive we recommend a certified lab for LC-MS/MS Confirmation.
These drug tests are intended for workplace testing & forensic use ONLY (not FDA cleared or CLIA waived).
Covid-19 IgG/IgM Rapid Test Cassette (Whole Blood/Serum/Plasma). Intended for qualitative detection and differntiation of IgM and IgG antibodies to SARS-CoV-2 in human venous whole blood, plasma from anticoagulated blood, or serum. The COVID-19 IgG/IgM Rapid Test Cassette (Whole Blood/Serum/Plasma) is intended for use as an aid in identifying individuals with an adaptive immune response to SARS-CoV-2, indicating recent or prior infection.
Materials Supplied-
25 sealed test pouches containing cassette, dropper and a desiccant
1 buffer
Co-Diagnostics Covid Molecular Test for labs and hospitals $12 FOB Utah, USA.
1) Highest Accuracy by Independent Testing. Don't settle for less.
2) 5 million tests produced weekly.
3) Best price for highest quality. Even works with old operating systems from the 90s.
4) 90 min result time.
Test kits are available in units of 100.
Send over an LOI with contact information and you will be speaking to the distribution team in less than 24 hours.
*COVID-19 Human IgM IgG Rapid Test provides a fast, convenient, and qualitative testing of human whole blood, plasma, and serum for COVID-19 IgM and IgG.
I Would Like To Talk To You About Our New Covid-19 Antibody Testing
Dear Medical Distributor,
My name is Alexander Camman,I have recently been in charge of all the business done in Peru.
WHPM Established in 1993 in Los Angeles California, has been designated a GMP registered center for in vitro diagnostic medical devices by the FDA.
Our IFOB colon cancer test is the #1 sold in the world.
I wanted to contact and introduce myself, as I will be your dedicated account manager and main point of contact here at WHPM, to make sure that all your needs are taken care of.
I'm excited to tell you about our new COVID-19 quick test that is CE Certified and made in the United States of America..
I would love to discuss how we can help introduce these products into your company's product line.
What is the best way to contact you?
I am open to communication on various platforms; mainly by phone, Email or Whatsapp. However, if you prefer another method of communication please let me know!
Please see all my contact options below. If you are interested you can contact me Direct.
Thank You For Your Time
1. Principle
This test kit is based on the competitive enzyme immunoassay for the detection of Gentamicin in the sample. The coupling antigen is pre-coated on the micro-well stripes. The Gentamicin in the sample and pre-coated coupling antigen on the micro-well stripes compete for the anti-Gentamicin antibody. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value of the sample has a negative correlation with the Gentamicin in it. The value is compared to the standard curve and the Gentamicin concentration is subsequently obtained.
1 Principle
This test kit is based on the competitive enzyme immunoassay for the detection of Fluoroquinolones in the pork, chicken, fish and shrimp, etc. The Fluoroquinolones in the sample and the coupling antigens pre-coated on the micro-well stripes compete for the anti-Fluoroquinolones antibodies. After the addition of the enzyme conjugate, the TMB substrate is added for coloration.The optical density (OD) value of the sample has a negative correlation with the Fluoroquinolones in the sample. This value is compared to the standard curve and the Fluoroquinolones concentration is subsequently obtained.
1. Principle
This test kit is based on the competitive enzyme immunoassay for the detection of Florfenicol in samples. The coupling antigens are pre-coated on the micro-well stripes. The Florfenicol in the sample and the conjugate antigens pre-coated on the micro-well stripes compete for the anti-Florfenicol antibodies. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value has a negative correlation with the Florfenicol concentration in the sample. This value is compared to the standard curve and the Florfenicol concentration is subsequently obtained.
1. Principle
This test kit is based on the competitive enzyme immunoassay for the detection of Tylosin in the sample. The coupling antigens are pre-coated on the micro-well stripes. The Tylosin in the sample and the coupling antigens pre-coated on the micro-well stripes compete for the anti-Tylosin antibody. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value of the sample has a negative correlation with the Tylosin in it. This value is compared to the standard curve and the Tylosin concentration is subsequently obtained.
ROC-F-OR003K Melamine ELISA Test Kit
1. Principle
This test kit is based on the competitive enzyme immunoassay for the detection of Melamine in the sample. The coupling antigen is pre-coated on the micro-well stripes. The Melamine in the sample and the coupling antigens pre-coated on the micro-well stripes compete for anti-Melamine antibodies. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value of the testing sample has a negative correlation with the Melamine concentration in the sample. This value is compared to the standard curve and the Melamine concentration is subsequently obtained.
Gentamicin is a broad spectrum antibiotic which is widely used as bacteriostatic agents in animal husbandry and veterinary practice. It may cause side effects on gastrointestinal tract, kidney, liver, hematological system. What is worse, it may cause allergic shock. Therefore, it is possible that tetracycline residues, after use in illegal practice, may lead to a risk for consumers.
The kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA) to assay the level of Human
Androgen in samples. Add Androgen to monoclonal antibody Enzyme well which is pre-coated with Human
Androgenmonoclonal antibody, incubation; then, add Androgenantibodies labeled with biotin, and combined with
Streptavidin-HRP to form immune complex; then carry out incubation and washing again to remove the uncombined enzyme.
Then add Chromogen Solution A, B, the color of the liquid changes into the blue, And at the effect of acid, the color finally
becomes yellow. The chroma of color and the concentration of the Human Substance Androgen of sample were positively
correlated.
The kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA) to assay the level of Rat
Dehydroepiandrosterone sulfate(DHEAS) in samples. Add Dehydroepiandrosterone sulfate(DHEAS) to monoclonal antibody
Enzyme well which is pre-coated with Rat Dehydroepiandrosterone sulfate(DHEAS)monoclonal antibody, incubation; then,
add Dehydroepiandrosterone sulfate(DHEAS)antibodies labeled with biotin, and combined with Streptavidin-HRP to form
immune complex; then carry out incubation and washing again to remove the uncombined enzyme. Then add Chromogen
Solution A, B, the color of the liquid changes into the blue, And at the effect of acid, the color finally becomes yellow. The
chroma of color and the concentration of the Rat Dehydroepiandrosterone sulfate(DHEAS) of sample were positively
correlated.