Please click here to check who's online and chat with them.

Find Verified Scientific Instruments Suppliers, Manufacturers and Wholesalers

Jun-20-14
 Inquire Now  
Pricinple of r1010:

The equipment for purification distillation test rotates and shapes a thin film in negative pressure condition by heating, evaporates efficiently, and then condenses and recollects solvent to purify and separate.

Features of r1010:


1. Teflon (ptfe) and fluorine rubber dual rotating seal, patented technology to ensure high vacuum.
2. The introduction of foreign advanced frequency control system, temperature control system, accurate and reliable.
3; a vacuum switching valve, without affecting the system vacuum distillation of the situation and the solution can be continuously collected.
4. Water bath electric lift and manual lift support, easy to use.
5; ptee discharge valve, corrosion resistance, pollution-free.

Parameters of r1010:


Model: r1010;
Rotary bottle:10l;
Collecting bottle:5l;
Speed-regulation of main machine: digital display, variable frequency, stepless speed-regulation;
10 to 130r/min, digitaldisplay of rotary speed;
90w motor;
Digital display, temperature control, 0~99degree;
Achievable vacuum:399.9pa (below 3mmhg);
Electric elevation;
0~160mm elevating stroke;


Dimensions(mm):920l*550w*1700h.
Jun-05-14
 Inquire Now  
Finity optical system, provides versatility and high quality images for bright field and phase contrast observation.

Ergonomically designed, constructed with high quality component through the whole microscopes.

KXD 100 mostly used for observation and research on living cell, tissue, fluid and deposit , especially unstained limpidity living materials.

College, University, Pharmacy, Agriculture and Animal husbandry department is inclined to use.


G.W.:15KGS, N.W.:11KGS,Meas.:58.6*58.6*33CM
May-20-14
 Inquire Now  
Specification
Wavelength: 190-1100nm
Band width: 2nm
Wavelength accuracy: +/-0.5nm
Wavelength repeatability: 0.2nm
Wavelength set: auto
Photometric accuracy: +/-0.5%t
Photometric repeatability: 0.2%t
Photometric range: h (500nm)
Noise: +/-0.001a
Stray light: 0.05%t (220nm& 360nm)
Data output: usb
Printer port: parallel port
Display mode: lcd(128*64dots)
Light: deuterium & tungsten lamp
Detector: silicon photodiode
Weight: 14kg

Foam plastic and outside with strong cartons
May-16-14
 Inquire Now  
Ambient temperature +5~40¡æ
Power consumption 850w 850w 1550w 2050w
Chamber volume 30l 50l 80l 136l
Internal dimension
(w¡ád¡áh, mm) 340¡á320¡á320 420¡á395¡á350 450¡á400¡á450 550¡á450¡á550
External dimension
(w¡ád¡áh, mm) 620*530*490 700*610*630 740¡á618¡á630 840¡á670¡á730
Shelves 2(pcs) 2(pcs) 2(pcs) 2(pcs)
Timing range 1~9999min


Model Jk-do-9240
Jk-do-9240a
Electrical requirements 220v 50hz
Temperature  range Rt+10~200¡æ/rt+10-250¡æ
Temperature accuracy 0.1¡æ
Display resolution ¡à1.0¡æ
Ambient temperature +5~40¡æ
Power consumption 2450w
Chamber volume 220l
Internal dimension
(w¡ád¡áh, mm) 600¡á500¡á750
External dimension
(w¡ád¡áh, mm) 880¡á720¡á930
Shelves 2(pcs)
May-16-14
 Inquire Now  
Speed range[rpm] 100-1600;
Speed display lcd ;
Speed display accuracy[rpm] 1 ;
Material stainless steel ;
Dimension of plate[mm] ¦õ135;
Heating power[w] 500;
Heat rate£¨1lwater£©[k/min]6;
Heating temperature range[¡æ] rt-350;
Temperature display lcd;
Temperature display accuracy[¡æ] 0.1;
Control accuracy of heating temperature[¡æ]1;
Adjustable safety circuit(heating plate)[¡æ] 100-350 ;
Temperature sensor of extra position pt100;
Control accuracy of heating temperature with temperature sensor[¡æ] 0.2;
Dimension[mm] 300¡á170¡á100;
Weight[kg] 2.8;
Permissible ambient temperature[¡æ] 5-40;
Permissible ambient humidity 80%;
Protection class acc. To din en60529 ip42;
Time range:ceramic surfaceith t shows having time control function, 0-9999 minutes is adjustable.
Rs232 interface yes;


Dimension[mm] 300¡á170¡á100;
Weight[kg] 2.8;
2220 Scientific Instruments Suppliers
Short on time? Let Scientific Instruments sellers contact you.
May-16-14
 Inquire Now  
Modeljk-hil-9052jk-hil-9082jk-hil-9162jk-hil-9272
Electrical requirement220v 50hz
Temperature  rangert+5~65¡æ
Display resolution0.1¡æ
Temperature stability¡à0.3¡æ
Ambient temperature+5~40¡æ

Interior dimension (w¡ád¡áh, mm)350¡á320¡á350400¡á400¡á500500¡á370¡á800520¡á460¡á1050
Shelves2(pcs)3(pcs)
Timing range1~9999min
May-13-14
 Inquire Now  
Wavelength: 190-1100nm
Band width: 2nm
Wavelength accuracy: +/-0.5nm
Wavelength repeatability: 0.2nm
Wavelength set: auto
Photometric accuracy: +/-0.5%t
Photometric repeatability: 0.2%t

Printer port: parallel port
Display mode: lcd(128*64dots)
Light: deuterium & tungsten lamp
Detector: silicon photodiode
Weight: 14kg

Weight: 15kg
Dimension: 520*450*350mm
Apr-23-14
 Inquire Now  
Ultrasonic distance meter/measurer
Color: Yellow/Red/Blue/Orange
With laser pointer
Foot/Meter display options
Measuring Range: 0.5m to 18m
LCD screen with LED backlight
Auto shutdown after 15 seconds without pressing any key
Memory: can store 3 measurement data for calculation of area and volume
Support sum-up, multiplication and subtraction of 2 measurement data.
All stored measurement data can be cleared.
Correction of errors: "Error" is displayed when the actual distance falls out of the measuring range
Power supply: 1 x 9V Alkaline type 6LR61 Battery (Not included)
Accuracy: +/-0.5%
Ultrasonic Frequency: 40 kHz
Working temperature: 0 ¡æ ~ 43 ¡æ
Dimensions (H-P-l): 142 x 73 x 47mm
Weight (without battery): 144.6g
Laser beam: Wattage 1mW (mW =milliwatt)
Wavelength: 650nm (nm =nanometer)
Package includes:
1 x Ultrasonic distance meter
1 x Instruction Manual

Ctn size¡¡§oo52*34*40cm
G.W: 15.5kg per carton
100 pcs per carton
Apr-23-14
 Inquire Now  
Light source lamp: preset germany heraeus deuterium lamp / osram long life halogen tungsten lamp


Uv1800 / uv1800pc specifications:
Photometric methods: transmittance, absorbance, energy, reflectivity
Wavelength range: 190nm-1100nm
Special bandwidth: 2nm
Stray light: ¡ü0.05%t (220nm, 360nm)
Wavelength accuracy: ¡ü¡à0.4nm
Wavelength reproducibility: ¡ü0.2nm
Photometric range: -3a ~ 3a
Photometric accuracy: ¡ü¡à0.3%t (0-100%t)
¡ü¡à0.002a (0-0.5a)
¡ü¡à0.004a (0.5-1a)
Photometric reproducibility: ¡ü0.001a (0-0.5a)
¡ü0.002a (0.5-1a)
Stability: ¡ü ¡à0.001a/h
Noise: ¡ü ¡à0.001a
Baseline flatness: ¡ü ¡à0.0015a
Power: 100-240v, 50/60hz
Light source: deuterium & tungsten-halogen lamp

Accessories:
Uv1800 spectrophotometer 1 set
Power cable 1 pc
Operation manual 1 pc
Certificate of quality checking 1 pc
Fuses (2 a) 2 pcs
10mm quartz cuvettes 2 cases
Packing list 2 pcs
Compact disc 1 pc (uv1800pc only)
Rs-232 cable 1 pc (uv1800pc only)
Dust cover 1 pc

Software specifications:
1. Such operation as photometric measurement, spectrum measurement, quantitative measurement, kinetic measurement are offered in uvcon windows applications.
2. Single-wavelength quantitative measurement can be measured with several kinds of arithmetic calculation methods to meet users¡¯ demand.
3. Curves can be measured and recalled in memory with data-handling of arithmetic calculation smooth, abs to/ from %t conversion and peak pick.
4. The measured data and graphics can be stored on pc/ printed/ output for reports.
Outstanding quality, keeping constant improving


Standard export packing
Apr-23-14
 Inquire Now  
Um lamp / osram long life halogen tungsten lamp

Uv1901 / uv1901pc specifications:
Photometric methods: transmittance, absorbance, energy, reflectivity
Wavelength range: 190nm-1100nm
Special bandwidth: 1nm
Stray light: ¡ü0.03%t (220nm, 360nm)
Wavelength accuracy: ¡ü¡à0.3nm
Wavelength reproducibility: ¡ü0.1nm
Photometric range: -4a ~ 4a
Photometric accuracy: ¡ü¡à0.3%t (0-100%t)
¡ü¡à0.002a (0-0.5a)
¡ü¡à0.004a (0.5-1a)
Photometric reproducibility: ¡ü0.001a (0-0.5a)
¡ü0.002a (0.5-1a)
Stability: ¡ü ¡à0.004a/h
Noise: ¡ü ¡à0.003a
Baseline flatness: ¡ü ¡à0.0008a
Power: 100-240v, 50/60hz
Light source: deuterium & tungsten-halogen lamp

Accessories:
Uv1900 series spectrophotometer 1 set
Power cable 1 pc
Operation manual 1 pc
Certificate of quality checking 1 pc
Fuses (2 a) 2 pcs
10mm quartz cuvettes 2 cases
Packing list 2 pcs
Compact disc 1 pc (uv1901pc & uv1902pc only)
Rs-232 cable 1 pc (uv1901pc & uv1902pc only)
Dust cover 1 pc

Software specifications:
1. Such operation as photometric measurement, spectrum measurement, quantitative measurement, kinetic measurement are offered in uvcon windows applications.
2. Single and multi-wavelength quantitative measurement can be measured with several kinds of arithmetic calculation methods to meet users¡¯ demand.
3. Curves can be measured and recalled in memory with data-handling of arithmetic calculation smooth, abs to/ from %t conversion and peak pick.
4. The measured data and graphics can be stored on pc/ printed/ output for reports.
Outstanding quality, keeping constant improving


Standard export packing
Apr-23-14
 Inquire Now  
¡ü¡à0.004a (0.5-1a)
Photometric reproducibility: ¡ü0.001a (0-0.5a)
¡ü0.002a (0.5-1a)
Stability: ¡ü ¡à0.001a/h
Noise: ¡ü ¡à0.001a
Baseline flatness: / ¡ü ¡à0.002a
Power: 100-240v, 50/60hz
Light source: deuterium & tungsten-halogen lamp

Accessories:
Uv1700 spectrophotometer 1 Set
Power cable 1 Pc
Operation manual 1 Pc
Certificate of quality checking 1 Pc
Fuses (2 a) 2 Pcs
10mm quartz cuvettes 2 Cases
Packing list 3 Pcs
Compact disc 1 Pc (uv1700pc only)
Rs-232 cable 1 Pc (uv1700pc only)
Dust cover 1 pc

Software specifications:
1. Such operation as photometric measurement, spectrum measurement, quantitative measurement, kinetic measurement are offered in uvcon windows applications.
2. Single-wavelength quantitative measurement can be measured with several kinds of arithmetic calculation methods to meet users¡¯ demand.
3. Curves can be measured and recalled in memory with data-handling of arithmetic calculation smooth, abs to/ from %t conversion and peak pick.
4. The measured data and graphics can be stored on pc/ printed/ output for reports.
Outstanding quality, keeping constant improving


Standard export packing
Apr-23-14
 Inquire Now  
Introduction:
Uv752 is single beam spectrophotometer that analyzes specimen materials in the ultraviolet and visible spectral d software this product is capable of charting and storing the scan results.


Uv752 specifications:
Model Uv752 752pc
Optical system: single beam, grating 1200 line/mm
Wavelength range: 200nm-1000nm
Wavelength accuracy: ¡à2.0nm
Wavelength reproducibility: 1nm
Wavelength readability: 0.1nm
Special bandwidth: 4nm
Photometric range: 0-125%t, -0.097-2.70a, 0-1999c
Photometric accuracy: ¡à0.5%t
Photometric reproducibility: 0.2%t
Stray light: ¡ü0.5%t (ƛ 220, 340nm)
Stability: ¡ü0.004a/1hr/500nm (after 30min warm up)
Light source: deuterium & tungsten-halogen lamp
Power: 220v 50hz
Display: Lcd(2*20)
Data output: Rs-232c
Analysis software: Without With
Dimensions: 440x370x200mm
Weight: 17kg

Accessories:
1. Uv752 spectrophotometer 1 set
2. Power cable 1 pc
3. Operation manual 1 pc
4. 10mm glass cuvettes 4 cases
5. 10mm quartz cuvettes 2 cases
6. Dust cover 1 pc
7. Printer cable 1 pc



Standard export packing
Apr-23-14
 Inquire Now  
Features:

Specifications:
Model723723pc723pcs
Optical system: single beam, grating 1200 line/nm
Wavelength range:325-1000nm
Wavelength accuracy: ¡à1nm
Wavelength reproducibility:¡ü0.5nm
Wavelength readability:0.1nm
Spectral bandwidth:4nm1, 2, 4, 5nm
Photometric range:0-125%t, -0.097-2.70a, 0-1999c, 0-1999f
Photometric accuracy:¡à0.5%t
Photometric reproducibility: 0.2%t
Stray light: ¡ü0.3%t (ƛ 340, 420nm)
¡ü0.2%t (ƛ 340, 420nm)
¡ü0.15%t(ƛ 340, 420nm)
Baseline flatness:/¡à0.005a
Stability:¡ü0.004a/1hr/500nm (after 30min warm up)
Power:220v 50hz
Display:Lcd(2x20)
Light source:Tungsten-halogen lamp
Data output:Rs-232c
Analysis software:SupportWith
Dimensions:440x370x200mm
Weight:17kg



Standard export packing
Apr-14-14
 Inquire Now  
Fusion splicer alk-88a (portable) fiber optic equipment is a mini type fusion splicing machine and have our own intellectual property right of fiber adjustment technology
It adopts advanced pas fiber adjustment technology . Adopt four motors drive, have fiber adjustment function, it is not only used for fttx project, but also can be used for the trunk line, it is a machine which is the smallest volume , the
Cooling pallet
Lcd
Replaceable heating unit
Heating device
Windproof cover
Fixing ring
Usb port
Keyboard position
Protection rubber
Operating instruction

25*30*40cm
8kg
Apr-14-14
 Inquire Now  
Fusion splicer alk-88a (portable) fiber optic equipment is a mini type fusion splicing machine and have our own intellectual property right of fiber adjustment technology
It adopts advanced pas fiber adjustment technology . Adopt four motors drive, have fiber adjustment function, it is not only used for fttx project, but also can be used for the trunk line, it is a machine which is the smallest volume , the
Products structure introduction/
Cooling pallet
Lcd
Replaceable heating unit
Heating device
Windproof cover
Fixing ring
Usb port
Keyboard position
Protection rubber
Operating instruction

Carton box25*30*40cm
Apr-14-14
 Inquire Now  
Fusion splicer alk-88a (portable) fiber optic equipment is a mini type fusion splicing machine and have our own
Lcd
Replaceable heating unit
Heating device
Windproof cover
Fixing ring
Usb port
Keyboard position
Protection rubber
Operating instruction

Carton box25*30*40cm
Apr-02-14
 Inquire Now  
¡ö high quality optical system, and optical components coated with special
Coating created a high-quality optical system.
¡ö standard magnification 7x~45x. Use optional auxiliary lens, the magnification
Can be 3.5x~180x
¡ö long working distance to create enough space for the uses
¡ö suit to ergonomic design, feel less fatigue when long time use

Carton and foam packing, two sets packed in one carton, size:50*40*38cm n.W.:8.2kg g.W.9.7kg
Apr-02-14
 Inquire Now  
¡ö High quality optical components coated with special film, created a high-
quality optical images.
¡ö Formed flat and good contrast image, especially in the peripheral visual
field, it is more bright and clear.
to get a clear image.
¡ö Suit to ergonomic design, the best height of the eyepoint, uses feel less
fatigue when long time use.
¡ö The zoom hand wheel (axial) bilateral settings, easy operation, high
precision zoom repeat.

carton and foam
carton size:50*40*38cm
GW:9.7KG NW:8.2KG
Apr-02-14
 Inquire Now  
Zoom range 0.8x-5x

Zoom ratio 1:6.3

Working distance 115mm

Dual led lighting, independent switch adjustable brightness (power: 3w)
Low security, low power consumption, low heat, long life
Column height: 240mm
Base size: 205x275x42mm


Carton and foam packing
Carton size:50*40*38cm
Gw:9.7kg nw:8.2kg
Jul-27-13
 Inquire Now  
Lens diameter 80mm
Magnification 1: 55 x
Magnification 2: 6 x
Focal length 450mm
Field of view 5.6¡ã(low power), 2¡ã(high power)
Near focus 1.5m(low power), 3m(high power)
Sensor cmos 5.0mega pixels (2592*1944)
Operation modes digital video camera+digital +pc camera
Camera resolution 5mp/3mp/2m/1mp
File format jpeg /avi
Internal memory 32mb
External memory sd slot (up to 2gb sdhc)
Lcd display 2 inch tft lcd
Zoom 6x digital zoom
Auto shoot 10s, 30s, 60s, 3min, 10min, 30min
Continuous video (approximate) 30 sec vga 30fps
4.5 min cif 15fps with internal memory




Product size/weight 440*130*125mm/1700g
10pcs/box g/w(kg) 16kg
2220 Scientific Instruments Suppliers
Short on time? Let Scientific Instruments sellers contact you.
See what buyers and suppliers are discussing in Scientific Instruments import export community