Please click here to check who's online and chat with them.

Find Verified Quality Control Services Suppliers, Manufacturers and Wholesalers

Top Supplier Cities : Mumbai   Chennai   New Delhi  
VERIFIED
Jun-09-21

Deif Genset Controller

$70
MOQ: 01  Pieces
Sample Available
 Inquire Now  
DEIF GENSET CONTROLLER
Automatic Genset Controller AGC-4 Mk II
The automatic genset controller AGC-4 MK II can be used as a single genset controller. Also, several AGCs can be connected in a complete power management system for synchronising projects, islanded or paralleled to the mains.

The generator controller is ideal for mission-critical applications such as hospitals and data centres, and it is capable of delivering backup power in only six seconds.
VERIFIED
Jun-08-21

Fuji Temperature Controller

$48
MOQ: 05  Pieces
Sample Available
 Inquire Now  
BRAND : FUJI TEMPERATURE CONTROLLER
PXF9 , PXF4, PXF5, PXF4 SOCKET TYPE ALL SERIES AVAILABLE .

Precise control:
Achieved a processing speed of 50 ms which is 10 times faster than conventional models. Reading accuracy is also improved from �±0.5% to �±0.2%*.
*Comparison under 0â??850�°C range, with RTD. See the Data Sheet for details.
Easy-to-see display
MVA LCD* which offers high contrast and wide viewing angle
Process value is displayed in white
*Minimal translucent type vertical alignment liquid crystal display
Practical options
Simple watt-hour metering function: allows you to monitor energy consumption
Operating days alarm: tells you the appropriate time for maintenance work
Most compact class in industry
36% smaller (than conventional models) and 58-mm depth shallow body helps downsize your facility
Universal input
You can use any input among RTD, thermocouples, voltage, current, and mV. The set-up for input change is very easy, only requires parameter change. This allows reduction of maintenance parts
VERIFIED
Jun-08-21

Rccb -Ge Power Controls

$13.80
MOQ: 01  Pieces
Sample Available
Supplier From Anand, Gujarat, India
 Inquire Now  
Brand: Ge Power Controls Rccb
40AMP, 300MA, 630A , NO/ OF POLE :4 , RCCB
VERIFIED
Jun-08-21

Wet Pid Temperature Controller

$90
MOQ: 01  Pieces
Sample Available
 Inquire Now  
BRAND: WEST PID TEMPERATURE CONTROLLER
WEST Controller:
Model: WEST-6100+,P6100
Model: WEST-4100+,P4100
Model: WEST-8100+,P8100
Features and Benefits:
Dual setpoints & optional remote selection
Plug-in output modules allow installing just the functions needed in
Expanded user-selectable operator modes in
User-selectable plug-and-play output cards in
Process and loop alarms in
Adjustable hysteresis in
Optional 10V SSR driver in
Improved Windows PC configuration software
Improved easy-to-use HMI
Jumperless input configuration
Auto-hardware recognition
Faster communication speeds
More security options
Backward compatible panel cutout, housing and terminal wiring capability
P6100/P6170/P8100/P4100
VERIFIED
Jun-07-21

Woodward Easygen Genset Controller

$555.55
MOQ: 01  Pieces
Sample Available
 Inquire Now  
Woodward Easygen 3000 XT Genset Controller, 12-24 V DC, IP Rating: IP20
Woodward Easygen 5000 XT Genset Controller, 12-24 V DC, IP Rating: IP20
Woodward raised the standard in genset paralleling control and power management system with the easYgen3000XT Series controllers. These controllers come with standardized software that is simple to configure, yet easily customized for individual applications. Enhanced connectivity enables fast and secure interfacing to other controls and communications systems while the enhanced hardware is a drop-in replacement for previous generation easYgen-3000 Series Controls.
318 Quality Control Services Suppliers
Short on time? Let Quality Control Services sellers contact you.
Mar-15-23

Mig/co2 Welding Wires , Saw Flux Etc

MOQ: 1  Metric Tonnes
Sample Available
 Inquire Now  
Stringent Quality Controls measures are adopted to ensure that welding wires are perfectly manufactured as per International Standards. ISO Quality Management system has been implemented as a result of which all products are of World-class Competence. Continuous efforts in the field of research and development are carried out so as to introduce new welding products and offer better services to all our customers.
Special Jumbo Spools and Drums have been developed for specific applications / SPM's. The Steel Bobbins are supplied as per Customer Specification and Schedules. Regular feedback is recorded and necessary corrective actions are taken in case of any complaints/suggestions received. Emphasis on Product & Quality up gradation has been a constant endeavour.
Welding Wires are uniformly and carefully Copper Coated. The coating thickness is maintained at optimum level so that fumes have minimum Copper. This is to protect welder's health and environment. Efforts are now focused to produce Copper Free Welding Wires.
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG61EG020SGCH
IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S
Technical specification
Relay model no CDG61EG020SGCH
Relay type CDG 61
Case size 3D HOR.
Application 2 O/C & 1 E/F
Current setting - O/C 0.5 to 2 amps
Contacts 3M S/R
Output contacts 2M S/R
C.T.Secondary 1 amps
Frequency 50 Hz
Burden 3 VA
Operating time 3 secs
Current setting - E/F 0.1 to 0.4 amps
High set - O/C Setting 4 to 16 amps
High set - E/F Setting 1 to 4 amps
High set/High set contact CAG 13 / 2M S/R
Name plate RFG9126 901
Outline drawing MFJ 014
Wiring diagram MADZ 821.27-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG61EG018SGCH
IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S
Technical specification
Relay model no CDG61EG018SGCH
Relay type CDG 61
Case size 3D H 30T
Application 2 O/C & 1 E/F
Current setting - O/C 0.5 to 2 amps
Contacts 3 N/O S/R
Output contacts 2 N/O S/R
C.T.Secondary 1 amps
Frequency 50 Hz
Tap Std
Burden / D.M.T 3 VA / 3 Secs
Current setting - E/F 0.2 to 0.8 amps
High set - O/C Setting 4 to 16 amps
High set - E/F Setting 2 to 8 amps
High set/High set contact CAG 13 / 2 N/O S/R
Name plate RFG9126 902
Outline drawing MFJ 014
Wiring diagram MADZ 821.27-1
VERIFIED
Jun-20-21
 Inquire Now  
GBCDG61EG011SGCH
IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI
Technical specification
Relay model no CDG61EG011SGCH
Relay type CDG 61
Case size 3D HOR.
Application 2 O/C & 1 E/F
Current setting - O/C 2.5 to 10 amps
Contacts 3M S/R
Output contacts 2M S/R
C.T.Secondary 5 amps
Taps / Frequency STD / 50 Hz
Burden 3 VA
Operating time 3 secs
Flag Yes
Current setting - E/F 1 to 4 amps
High set - O/C Setting 20 to 80 amps
High set - E/F Setting 10 to 40 amps
High set/High set contact CAG 13 / 2M S/R
Name plate RFG9126 904
Outline drawing MFJ 014
Wiring diagram MADZ 821.27-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG61EG006SXCH
IDMT THREE O/C RELAY WITH HIGH-SET
Technical specification
Relay model no CDG61EG006SXCH
Relay type CDG 61
Case size 3D HOR.30T
Application O/C
Current setting - O/C 0.5 to 2 amps
Contacts 3M S/R
Output contacts 2M S/R
C.T.Secondary 1 amps
Taps Std
Frequency 50 Hz
Burden 3 VA
Operating time 3 secs
Flag Yes
High set - O/C Setting 4 to 16 amps
High set/High set contact CAG 13 / 2M S/R
Name plate RFG9126 771
Outline drawing MFJ 014
Wiring diagram MADZ 821.27-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG61EG003SXCH
IDMT THREE O/C RELAY WITH HIGH-SET
Technical Specification
Relay model no CDG61EG003SXCH
Relay type CDG 61
Case size 3D HOR.30T
Application O/C
Current setting - O/C 2.5 to 10 amps
Contacts 3Meter S/R
Output contacts 2M S/R
C.T.Secondary 5 amps
Taps Std
Frequency 50 Hz
Burden 3 VA
Operating time 3 secs
Flag Yes
High set - O/C Setting 20 to 80 amps
High set/High set contact CAG 13 / 2M S/R
Name plate RFG9126 774
Outline drawing MFJ 014
Wiring Diagram MADZ 821.27-1
VERIFIED
Jun-20-21

Alstom Relay

$1.50K
MOQ: 01  Pieces
 Inquire Now  
Alstom Gbcdg61eg001zmch
Obs.replaced by Gbcdg61eg101zmch
Obs Model .replaced by Model List Gbcdg61eg101zmch
VERIFIED
Jun-20-21
 Inquire Now  
Alstom Gbcdg31ff8111lch
3idmt,2o/c & 1e/f,3va 1.3secs, Dmt 50hz
Technical Specification
Relay Model No Cdg31ff8111lch
Type Cdg31
Application 2 O/c + 1 E/f
Burden / D.m.t. 3va / 1.3 Sec.
C.t. Secondary 5 Amp C.t.
Case Size 3d Vert.
Contacts (S/r or H/r) 2 N/o 2 N/c H/r
E/f Setting 1 - 4 Amps.
Flag Yes
Frequency 50 Hz
Mounting Flush
O/c Setting 2.5 - 10 Amps.
Name Plate Rfg9125-904
Outline Drawing Mfj013
Wiring Diagram Mfdz801.95-1
VERIFIED
Jun-20-21
 Inquire Now  
Alstom Gbcdg31ff8101lch
3idmt,2 O/c & 1 E/f ,3va 3 Secs Dmt 50hz
Technical Specification
Model No. Cdg31ff8101lch
Case Size : 3d Ver.
Application : 2 O/c & 1 E/f
Ct Secondary : 5 Amps
Current Setting O/c : 2.5 to 10 Amps
Current Setting E/f : 1 to 4 Amps
Contacts : 2m 2b H/r.
Output Contacts : 2m 2b H/r.
Taps : Std.
Burden / Operating Time : 3 Va 3 Secs.
Frequency : 50 Hz.
Name Plate : Rfg9126 904
O/l & Arrangement : Mfj 013
Wiring Diagram : Mfdz 801.95 - 1
VERIFIED
Jun-20-21
 Inquire Now  
GBCDG31FF021SBCH
IDMT 2 O/C & 1 E/F RELAYS SPL 150 HZ.
Technical specification
Relay model No CDG31FF021SBCH
Relay type CDG 31 Special
Case size 3D V 20T
Application 2 O/C & 1 E/F
Current setting - O/C 2.5 to 10 amps
Current setting - E/F 0.5 to 2 amps
Contacts 3 N/O S/R
Output contacts 2 N/O S/R
Taps Std
BURDE / D.M.T 3 VA / 3 Secs
C.T.Secondary 5 amps
Frequency 150 Hz
Flag Yes
Mounting Flush
Note to test:Relay to test
150 Hz. refer test inst.
Name Plate RFG9126 903
Outline drawing MFJ 013
Wiring diagram MFDZ 801.101-1
VERIFIED
Jun-20-21
 Inquire Now  
GBCDG31FF015SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Technical specification
Relay model No CDG31FF015SBCH
Relay type CDG 31 Special
Case size 3D V 20T
Application 2 O/C & 1 E/F
Current setting - O/C 0.5 to 2 amps
Current setting - E/F 0.2 to 0.8 amps
Contacts 3 N/O S/R
Output contacts 2 N/O S/R
Taps Std
BURDE / D.M.T 3 VA / 1.3 Secs
C.T.Secondary 1 amps
Frequency 50 Hz
Flag Yes
Mounting Flush
Name Plate RFG9125 902
Outline drawing MFJ 013
Wiring diagram MFDZ 801.130-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31FF014SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31FF014SD(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 0.1 - 0.4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
NAME PLATE - RFG9125 901
Outline Diagram MFJ 013
Wiring Diagram MFDZ801-103-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31FF014SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31FF014SBCH
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.1 - 0.4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
NAME PLATE - RFG9125 901
Outline Diagram MFJ013
Wiring Diagram MFDZ801-101-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31FF013SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31FF013SD(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 0.2 - 0.8 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
NAME PLATE - RFG9125 902
Outline Diagram MFJ 013
Wiring Diagram MFDZ801-103-1
VERIFIED
Jun-20-21
 Inquire Now  
GBCDG31FF013SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31FF013SB(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.2 - 0.8 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
NAME PLATE - RFG9125 902
Outline Diagram MFJ 013
Wiring Diagram MFDZ801-101-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31FF012SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31FF012SD(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 0.5 - 2 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
NAME PLATE - RFG9125 903
Outline Diagram MFJ 013
Wiring Diagram MFDZ801-103-1
VERIFIED
Jun-20-21
 Inquire Now  
GBCDG31FF012SCCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No : CDG31FF012SC(M)
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
Name Plate RFG9125771
Outline Diagram MFJ013
Wiring Diagram MFDZ801-103-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31FF012SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31FF012SB(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.5 - 2 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
NAME PLATE - RFG9125 903
Outline Diagram MFJ 013
Wiring Diagram MFDZ801-101-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31FF012SACH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No : CDG31FF012SA(M)
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O S/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
Name Plate RFG9125671
Outline Diagram MFJ013
Wiring Diagram MFDZ801-101-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31FF011SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Technical specification
Relay Model No CDG31FF011SDCH
Relay type CDG 31
Case size 3D V 20T
Application 2 O/C + 1 E/F
Burden / D.M.T 3 VA / 1.3 Sec
C.T.Secondary 5 amps
Contacs (S/R OR H/R) 2 N/O 2 N/C H/R
E/F Setting 1 - 4 Amps.
Flag Yes
Frequency 50 Hz
Mounting Flush
O/C Setting 2.5 - 10 Amps.
Name plate RFG9125 904
Outline Diagram MFJ 013
Wiring Diagram MFDZ801-103-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31FF011SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31FF011SB(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 1 - 4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
NAME PLATE - RFG9125 904
Outline Diagram MFJ 013
Wiring Diagram MFDZ801-101-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31FF011SACH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No : CDG31FF011SA(M)
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O S/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate RFG9125 674
Outline Diagram MFJ013
Wiring Diagram MFDZ801-101-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31FF005SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Technical Specifications
Relay Model No CDG31FF005SBCH
Relay type CDG 31 Special
Case size 3D V 20T
Application 2 O/C & 1 E/F
Current setting - O/C 0.5 to 2 amps
Contacts 3 N/O S/R
Output contacts 2 N/O S/R
Taps Std
C.T.Secondary 1 amps
Burden 3 VA
Operating time 3 secs
Current setting - E/F 0.2 to 0.8 amps
Flag Yes
Mounting Flush
Name Plate RFG9126 902
Outline Diagram MFJ 013
Wiring Diagram MFDZ 801.130-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31FF004SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31FF004SD(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA /3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 0.1 - 0.4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
NAME PLATE - RFG9126 901
Outline Diagram MFJ 013
Wiring Diagram MFDZ801-103-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31FF004SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31FF004SB(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.1 - 0.4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
NAME PLATE - RFG9126 901
Outline Diagram MFJ 013
Wiring Diagram MFDZ801-101-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31FF003SDCH
IDMT 2 O/C & 1 E/F RELAYS
Technical specification
RELAY MODEL NO CDG31FF003SDCH
Relay type CDG 31
CASE SIZE 3D VER.
APPLICATION 2 O/C & 1 E/F
CURR.SETTING O/C .5 TO 2 AMPS
CURR.SETTING E/F .2 TO .8 AMPS
CONATCTS 2M 2B H/R
OUTPUT CONTACTS 2M 2B H/R
TAPS STD
FREQUENCY 50 HZ
C.T.SECONTARY 1 AMPS
BURDEN / OPERATING TIME 3 VA / 3 SECS.
NAME PLATE RFG9126 902
OUTLINE DRAWING MFJ 013
WIRING DIAGRAM MFDZ801.103-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31FF003SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31FF003SB(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.2 - 0.8 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
NAME PLATE - RFG9126 902
Outline Diagram MFJ 013
Wiring Diagram MFDZ801-101-1
VERIFIED
Jun-20-21
 Inquire Now  
GBCDG31FF002SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31FF002SB(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.5 - 2 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
NAME PLATE - RFG9126 903
Outline Diagram MFJ 013
Wiring Diagram MFDZ801-101-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31FF002SDCH
IDMT 2 O/C & 1 E/F RELAY SELF POWERED.
MODEL No CDG31FF002SDCH
RELAY TYPE CDG 31
APPLICATION 2 O/C + 1 E/F
BURDEN / D.M.T 3 VA / 3 SEC.
C.T. SECONDARY 5 AMP C.T.
CASE SIZE 3D VERT.
CONTACTS (S/R OR H/R) 2 N/O 2 N/C H/R
E/F SETTING 0.5 - 2 Amps.
FLAG YES
FREQUENCY 50 HZ
MOUNTING FLUSH
O/C SETTING 2.5 - 10 Amps.
NAME PLATE RFG9126 903
OUTLINE DRAWING MFJ 013
WIRING DIAGRAM MFDZ801-103-1
VERIFIED
Jun-20-21
 Inquire Now  
GBCDG31FF002SCCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Tecnical specification
Model No : CDG31FF002SC(M)
CDG31
Case Size - 3D Vert
Application - 3 O/C
O/C Setting - 0.5 - 2 Amps.
Contacts - 2 N/O 2 N/C H/R
Taps - Std
Frequency - 50 Hz
C.T. Secondary - 1 Amp
Burden / D.M.T - 3 Va / 3 Sec
Flag - Yes
Mounting - Flush
Name Plate RFG9126771
Outline Diagram MFJ013
Wiring Diagram MFDZ801.103-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31FF001SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31FF001SD(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 1 - 4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
NAME PLATE - RFG9126 904
Outline Diagram MFJ 013
Wiring Diagram MFDZ801-103-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31FF002SACH
NON DIR.SELF POWER 3 O/C RELAY 2M S/R
Model No : CDG31FF002SA(M)
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O S/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
Name Plate RFG9126671
Outline Diagram MFJ013
Wiring Diagram MFDZ801-101-1
VERIFIED
Jun-20-21

Alstom Idmt 3 O/c Relays

$1.50K
MOQ: 01  Pieces
 Inquire Now  
Alstom Gbcdg31ff001scch
Idmt 3 O/c Relays
Relay Model Cdg31ff001scch
Cdg31
Application 3 O/c
Burden / D.m.t 3 Va / 3 Sec.
C.t. Secondary 5 Amp C.t.
Case Size 3d Vert.
Contacts (S/r or H/r) 2 N/o 2 N/c H/r
Flag Yes
Frequency 50 Hz
Mounting Flush
O/c Setting 2.5 - 10 Amps.
Name Plate-1 Rfg9126674
Outline Drawing Mfj013
Wiring Diagram Mfdz801-103-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31FF001SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Technical Specifications
Model No - CDG31FF001SB(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 1 - 4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
NAME PLATE - RFG9126 904
Outline Diagram MFJ 013
Wiring Diagram MFDZ801-101-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31EG8114LCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
TECHNICAL SPECIFIFICATION
Model No : CDG31EG8114LCH
CDG31 Ac Series Trip
Application - 2 O/C + 1 E/F
Case Size - 3D Horz
C.T. Secondary - 1 Amp
Burden / D.M.T - 3 Va / 1.3 Sec
O/C Setting - 0.5 - 2 Amps
Tap - Std.
E/F Setting - 0.1 - 0.4 Amps
Contacts - 2 N/O 2 N/C H/R
Flag - Yes
Frequency - 50 Hz
Mounting - Flush
Name Plate - RFG9125 901
Outline Diagram MFJ014
Wiring Diagram MADZ821-17
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31EG8112LCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
TECHNICAL SPECIFICATION
Model No : - CDG31EG8112LCH
RELAY TYPE - CDG31 AC S/T
APPLICATION - 2 O/C + 1 E/F
C.T. SECONDARY - 5 AMP C.T.
O/C SETTING - 2.5 - 10 Amps.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 0.5 - 2 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
BURDEN / D.M.T - 3 VA / 1.3 SEC.
TAPS - STD
Name Plate - RFG9125 903
Outline Diagram MFJ014
Wiring Diagram MADZ821-17
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31EG8111LCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
TECHNICAL SPECIFIFICATION
Model No : CDG31EG8111LCH
CDG31S/T
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 1 - 4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps
Name Plate - RFG9125 904
Outline Diagram MFJ014
Wiring Diagram MADZ821-17
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31EG8111KCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
RELAY MODEL CDG31EG8111KCH
APPLICATION 3 O/C
BURDEN / D.M.T 3 VA / 1.3 SEC.
C.T. SECONDARY 5 AMP C.T.
CASE SIZE 3D HORZ.
CONTACTS (S/R OR H/R) 2 N/O 2 N/C H/R
FLAG YES
FREQUENCY 50 HZ
MOUNTING FLUSH
O/C SETTING 2.5 - 10 Amps.
NAME PLATE-1 RFG9125 774
OUTLINE DRAWING MFJ014
WIRING DIAGRAM MADZ821-17
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31EG8106LCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
Relay model no CDG31EG8106LCH
Relay type CDG31
Case Size 3D Hor
Application 2 O/C & 1 E/F
C.T.Secondary 5 Amps
Current Setting - O/C 2.5 TO 10 Amps
Current Setting - E/F 1 TO 4 Amps
Contacts 2 N/O 2 N/C H/R
Output Contacts 2 N/O 2 N/C H/R
Taps STD
Burden / Operating Time 3 Va / 3 Secs.
Frequency 50 Hz
Name Plate RFG9126 904
Outline Drawing MFJ 014
Wiring Diagram MADZ821.42
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31EG8102LCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
Model No : - CDG31EG8102L(M)
RELAY TYPE - CDG31S/T
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 0.5 - 2 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate - RFG9126 903
Outline Diagram MFJ014
Wiring Diagram MADZ821-17
VERIFIED
Jun-20-21
 Inquire Now  
GBCDG31EG8101LCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
Model No - CDG31EG8101L(M)
RELAY TYPE - CDG31S/T
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 1 - 4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate - RFG9126 904
Outline Diagram MFJ014
Wiring Diagram MADZ821-17
VERIFIED
Jun-20-21
 Inquire Now  
GBCDG31EG8101KCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
Model No : CDG31EG8101K(M)
CDG31S/T
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C OR O/V SETTING - 2.5 -10 Amps.
Name Plate RFG9126 774
Outline Diagram MFJ014
Wiring Diagram MADZ821-17
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31EG604SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Technical Details
RELAY TYPE - CDG 31
Model No - CDG31EG604SBCH
Application - 2 O/C + 1 E/F
Case Size - 3D HORZ.
C.T. Secondary - 1 Amp
O/C Setting - 0.5 - 2 Amps.
E/F Setting - 0.1 - 0.4 Amps.
Burden /D.M.T - 3 VA /3 Sec.
Taps - Std
Contacts - 3 N/O S/R
Output Contacts - 2 N/O S/R
Flag - Yes
Frequency - 60 Hz
Mounting - Flush
Write in Name Plate As 60 Hz instead of 50 Hz.
Name Plate - RFG9126 901
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31EG022SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Technical specification
Relay model no CDG31EG022SB(M)
Relay type CDG 31
Case size 3D HOR.
Application 2 O/C & 1 E/F
Current setting - O/C 1 to 4 amps
Contacts 3M S/R
Output contacts 2M S/R
Taps / C.T.Secondary STD / 5 amps
Burden 3 VA
Flag Yes
Operating time 3 secs
Current setting - E/F 0.5 to 2 amps
Frequency 50 Hz
Name plate RFG9126 796
Name plate - 1 RFG9126 795
Outline drawing MFJ 014
Wiring diagram MADZ 802.63-1
VERIFIED
Jun-20-21
 Inquire Now  
ALSTOM GBCDG31EG014SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG014SD(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 0.1 - 0.4 Amps
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
NAME PLATE - RFG9125 901
Outline Diagram MFJ 014
Wiring Diagram MADZ802.64-1
318 Quality Control Services Suppliers
Short on time? Let Quality Control Services sellers contact you.
Explore Quality Control Services related import export discussions