Please click here to check who's online and chat with them.

Find Verified Laboratory Equipments Instruments Suppliers, Manufacturers and Wholesalers

Jun-06-11
 
Singh Science Systems gives a good faith to customers, our super plus model is very atractive design & good eccuracy Click-stop digital systems, click sound at each increment during volume setting ensures no superfluous volume variation during pipetting. Strong & latest design, frivolous weight and soft plunger movement provides conform and reduces hand fatigue. Use for long life & easy tip ejecting technology. Ultimate for genetics & biotech application, tissue culture cellular & molecular biology laboratories, hospital, quality control & research labs. Easy volume setting by simply spinning the plunger. Easy and smooth, operation does not rip up hand gloves. Companionable with all major make of tips. Accuracy and precision both are guaranteed. Autoclavable tip cone. (Partially Autoclavable). Each pipette has a calibration report, ensure pre-dispatch quality check.
May-06-11
 
39- liters laboratory flotation machine is applied in ore dressing by the method of laboratory floating. It is concatenation floatation machine with several sets of machines. And the number of chutes is even from 1 to 10. It is left-type or right-type according to user's demand.

Structure and features:
Laboratory flotation machine with 39 liters is impeller mechanical flotation machine. It is composed by the following main parts:
(1). Tank
The tank 1 is welded with steel plate, using the impeller to stir, simultaneously inflating the air into pulp.
In order to adjust the thickness of slurry surface in tank and foam layer scraped, the intermediate tank 15 is made up of two slot panels, in which is the pulp surface regulator 5 installed, orifice 17 is installed on the tank cover 14, which is used to prevent the chaotic movement of pulp affects on the bubble zone, the gangue is entrained mechanically to the concentrate.
Basin liner 6 is equipped in the tank to prevent the tank bottom worn, basin liner can be replaced. Discharging port 8 is placed outside the tank bottom, which is used to storage water when cleaning.
The pulp flows into the intermediate tank 15 and the end tank 3 from the overflow port on the panel, the catheters of the intermediate tank bottom and the cover 14 on the groove wall bottom are put into the next tank, which will flow continuously through all the tanks of flotation machine. The pulp is fed from the feed chute 3, is discharged from the discharging port 8 of the tailing 1, the feed port 16 is equipped in front and at the back of tank bottom, which is easy to change the technological process.
(2)Impeller system
Impeller system is installed in the center of the flotation tank, the vertical arrangement coiled impeller 9 which leaves are up is fixed at the bottom of the impeller shaft 10 and around the vertical shaft tube 12. The tube top is located over the pulp stone and foam layer, the tube bottom is bearing the cover 14. When the impeller rotates, the quantities of air can be absorbed along the vertical tube 12. The protective plate 4 is fixed under the cover 14, the gap between the protective plate and impeller is related to the aeration rate, its maximum gap is less than 3mm, if the gap is too large, it is necessary to replace the protective plate or be adjusted appropriately.
The hole of vertical tube 12 is used to cycle pulp, and make the pulp and air mix well. The upper of the impeller shaft rotates in the rolling shaft 11 installed in the bearing shell, the bearing shell is installed on the beam 7. The pulley fixed at the top of the shaft makes the motor 18 rotating through the triangle belt, of which the tension can be adjusted by the nut 19.
(3). Shaving foam device
Foam is scraped using the rotary scraper along the flotation machine, scraper 20 is installed out of the discharging port. The pulley is installed at the end of the scraper shaft, which rotates through the driving of the worm reducer 21 and V-belt.

Technical parameters
(1)Tank size: L¡ÁW¡ÁH 315¡Á315mm¡Á527mm
(2)The effective volume: 39 liters
(3)The flow of the pulp is calculated according to the production capacity
(4)Aeration rate: 35-45 liters / min
(5)Impeller diameter:200mm
(6)Impeller speed: 809m/s
(7)Impeller circumferential speed:8.14m/s
(8)Scraper rpm: big wheel/small wheel 21r/min /13r/min
(9)Motor: Model y900l-4 voltage :220/380V.

Power:1.5KW rpm: 1400 r / min
(10)Assembly method: Left-style
(11)The outline size of machine: H: 930mm, W: 762mm, L (including 2 slots)1081mm
(12)Total weight:(including 2 slot motors).
Apr-29-11
 
ZY6014A (Vertical-specimen) Flame Tester

1.Introduction:
This apparatus is certificated by Guangzhou Hua Mei UL company ,it applies to research and manufacture for illumination, household, machine tool, motor, and such electric and electronic equipments and parts. It is also used to insulation materials, project plastics and other materials.

2. Standards: UL1581(section 1080.1£­1080.14) , UL13. UL14 UL1655(VW-1 burning test). CSA (FT-1¡¢FT-2)

3. Main components: burning chamber ¡¢observation Windows¡¢ operation windows¡¢control system ¡¢gas control and so on .

4. Main parameters :
4.1 Burning chamber outside size: 2.4m(L)*1m(W)*2.5m(H)
4.2 Observation Windows: 3 observation Windows, made by reinforced glass,
size: 730mm(H)*420mm(W)
4.3 Operation windows: 4 operation windows, interior diameter 150mm, outside diameter 220mm.sealed by 600mm long-arm leather glove.
4.4 Air inlet : 4 air inlets ,which diameter is 160mm,
4.5 Bottom anchor : bottom anchor size 2.4(L)*1m(W)*0.7m(H), 6 pulleys of which 4 are with lock.
4.6 Light equipment : 1 anti-fog,anti-smoke,ring lamp.
4.7 Control system: 1 sheet of burning instrument, 0 to 99.99s setting arbitrarily. 1 sheet of stop burning instrument, 0 to 99.99s setting arbitrarily . 0 to 999999 times setting arbitrarily.


negotiable
Apr-29-11
 
ZY6056 Needle Flame Tester

1. Introduction :
This device applies to electrical and electronic equipment and components ,also suitable for electrical insulating materials or other solid materials ,using simulation technology assess dangerous of catching fire or flame driven from internal equipment under fault condition.

2. Standards: IEC60695-2-2. GB/T5169.5-1997.

3. Main components: needle combustor, temperature measurement system , test chamber and so on.

4. Main parameters
4.1 Burner :inner diameter 0.5mm, length 35mm.
4.2 Flame standard : length more than 12mm.
4.3 Heat speed :100 - 700C costs 2.5S
4.4 Chamber capacity 0.5M 60cm(L) * 95cm(W) * 90cm(H)
4.5 Conductive copper ¥Õ4.0 * 6.0mm,
4.6 Outsize :61cm(D) * 120cm(W) * 105cm(H).
Apr-29-11
 
ZY6078 Vulcanization Tester

1. Introduction : This device applies to show vulcanization curve , so that a new hand can easily get the best reasonable ingredients and balanceable formula of scorching and vulcanization by computer and software .

2. Main components :
2.1 Machine parts: cabinet , upper and bottom mould cavity ,and so on.
2.2 Electrical control system
2.3 Printer
2.4 Pneumatic system.
4986 Laboratory Equipments Instruments Suppliers
Short on time? Let Laboratory Equipments Instruments sellers contact you.
Apr-29-11
 
ZY 6192 Halogen Release Measurement Device

1. Introduction: this device applies to measure halogen content PH conductivity when wires and cables are burning according to IEC60754.

2. Standards:GB/T17650.1-1998, GB/T17650.2-1998, IEC60754-1:1994, IEC60754-2:1991 . GB/T19666-2005, GA306.1-2007, GA306.2-2007, UL2556-2007.

3. Main components : quarts material tubular furnace combustion tube, air collection system, air supply system , PH meter , conductivity analyzer

4. Main parameters:
4.1 Tubular furnace chamber size : 42mm * 600mm, power input :220V/10kw.
4.2 Combustion tube 40mm,
4.3 PH meter : precision 0.02PH.
4.4 Conductivity : measurement scope :(0~1¡Á105)¦ÌS/ cm.
4.5 Air flex meter :20-200L adjustable.
Apr-20-11
 
LK ¡§C210A Black -white Densimeter


Features:
This product uses circuits of high-tech products, working with the advantages of accurate measurement, good stability, convenient operation, etc.


Parameter:

Density range : 0 = 0.00-5.00
Light hole size : Dia 2mm
Reading stability : about 0.02
Uncertainty : 0.00-3.00 0.02D, 3.00-4.00 0.04D, 4.00-5.00 0.08D
Display form : 3 digits display
Sampling time : 0.8s
Working environment : 0 ¡§C 40, relative humidity <=85%
Power supply : 50-60HZ 220V +/- 10%
Dimension : 300*270* 130mm (length* width*height)
Power consumption : 25W.


Dimension:300*270* 130mm (length* width*height)
Al-alloy case.
Apr-19-11
 
Hardness tester LK120

Features:
Easy one handed operation
Digital Display
Compact body for areas of restricted space
Slim detector allows measurements to be taken on complex curved surfaces such as welds, moulds etc, as well as conventional flat surfaces
Conversion function for different hardness scales
Self calibrating
Supplied with NAMAS certified test piece
Used in any direction
Lightweight, portable and easy to carry
Using large-screen 128 * 64 dot matrix LCD module, information abundant and intuitive.
Can be pre-set limit, hardness, when beyond the scope it automatic alarm, convenience customers batch test.
English display: menu type operation, uses simple and convenient.

Technical parameter:
Measuring scope: HLD (170-960) HLD
Measuring direction: support plummet, inclined, level, oblique, pure vertical
measured material: Steel ,alloy steel, stainless steel, grey cast iron, ductile iron, zinc alloy, copper alloy ,casting of copper, , Copper alloy (brass, bronze), pure copper, forged steel .
Hardness formats: HL,HB, HRB, HRC,HRA,HV,HS
Display: high contrast segment code type LCD display
Data storage: maximum 500 groups (impact times: 32-1)
Paper width: 57.5¡À0.5£©mm Paper coil diameter: 30mm
Work voltage: 6V Nimh batteries
Work Time: about 150h, With power saving function like auto dormancy,
automatic shutdown etc.
Measuring direction: 360¡ã
operating temperature: -10 ~ +50¡æ
Shape dimension:213*80*215mm
relative humidity: <=90%
Weight:600g.


Shape dimension:213*80*215mm
Weight:600g.

Al-alloy case
Mar-31-11
 
Table-top high speed refrigerated centrifuge.
Mar-31-11
 
Floor-type/table-top high speed refrigerated centrifuge.
Mar-31-11
 
- Combined function of washing, spin-drying, concentration and filtering
-Touch-pad design, all digital display for simple handling and clear display
-Programmable speed and time
-Special vibration-absorbing combination for automatic balance and lowest noise
-Eliminate most re-spins
-All stainless construction
-Light weight and high efficacy
-Drying degree above 90%
Mar-31-11
 
High-speed refrigerated centrifuge.
Mar-25-11
 
Temperature£º<-50¡æ, -80¡æ (optional)
vacuum :<15Pa
Freeze-dry acreage£º0.07-0.12m2
Water-Capture Capability£º3Kg/24h
Capacity£º0.7¡«1.2L
Size: 580¡Á560¡Á340(mm)
Material Tray: the diameter of material-dry tray is180mm, three layers; four layers; install the material about 900ml(material thickness 10mm), or placed 135 bottles, the diameter of 22mm.
Freeze dry time: about 24h(material thickness 10 mm).


N/W:75KG G/W:90KG.
Mar-25-11
 
Temperature£º<-50¡æ, -80¡æ (optional)
vacuum :<15Pa
Freeze-dry acreage£º0.09-0.18m2
Water-Capture Capability£º3Kg/24h
Capacity£º0.7¡«1.2L
Size: 560¡Á460¡Á(720+450)(mm)
Sample Tray£ºStainless steel sample holder with special design, can option the space between layers, can enactment the number of layers, the diameter of material-dry tray is 200mm,four layers; install the material about 1500ml(material thickness 10mm).





N/w:90kg g/w:100kg.
Mar-25-11
 
1.pre-freezing at in situ situation, transparent organic glass door to observe working procedure.
2.The tray temperuate adjustable,controllable, detectable ;its suitable for pilot scale and small production.
3.LCD display working situation and PID control,drying curving display on the LCD.
4.optional gas valve to fill with inert gases like nitrogen gas.

Drying area :0.2©O
No. of trays :2
Condenser lowest temperature: ¡Ü-50¡æ ¡Ü-70¡æ£¨optional£©
tray temperature range: -50¡æ¡«50¡æ
Distance between trays :70mm
trays size :265mm*400mm*25mmX2mm
Water capture: 3Kg/24h
Liquid loading capacity :2L
22 vial 370pcs
16 vial 768pcs
14 vial 970pcs
12 vial 1300pcs
Vaccum degree ¡Ü10Pa
Mashine cooling Air cooling
External dimension 600mm*660mm*1100mm.

External dimension 600mm*660mm*1100mm.
Mar-23-11
Supplier From Solan, Himachal Pradesh, India
 
Universal fit pipette tips.
Mar-23-11
Supplier From Solan, Himachal Pradesh, India
 
90mm petri dish, sterile.
Mar-04-11
 
Our Company research IC Crack ,MCU Crack, Code Extraction, CPLD, FPGA, ASIC and Custom ICs part Number Identification...

ST62E01C Features
¡¤ Memories
¨C 1K or 2K bytes Program memory (OTP,
EPROM, FASTROM or ROM) with read-out
protection
¨C 64 bytes RAM
¡¤ Clock, Reset and Supply Management
¨C Enhanced reset system
¨C Low Voltage Detector (LVD) for Safe Reset
¨C Clock sources: crystal/ceramic resonator or
RC network, external clock, backup oscillator
(LFAO)
¨C Oscillator Safeguard (OSG)
¨C 2 Power Saving Modes: Wait and Stop
¡¤ Interrupt Management
¨C 4 interrupt vectors plus NMI and RESET
¨C 9 external interrupt lines (on 2 vectors)
¡¤ 9 I/O Ports
¨C 9 multifunctional bidirectional I/O lines
¨C 4 alternate function lines
¨C 3 high sink outputs (20mA)
¡¤ 2 Timers
¨C Configurable watchdog timer
¨C 8-bit timer/counter with a 7-bit prescaler
¡¤ Analog Peripheral
¨C 8-bit ADC with 4 input channels (except on
ST6203C)
¡¤ Instruction Set
¨C 8-bit data manipulation
¨C 40 basic instructions
¨C 9 addressing modes
¨C Bit manipulation.
Feb-17-11
 
Jacketed glass reactor is an ideal instrument for pharmacy, biology, fine chemistry and material synthesis. With menstruum in inlayer and heating or cooling source in interlayer, jacket glass reactor can perform synthesis, distillation, separation and reflux under airproof condition. Now we can supply you jacketed glass reactor from 1-100L.

Function:
Putting reaction solvent into jacketed layer of glass reactor to do stirring reaction, the jacketed layer can do constant temperature, heating and cooling reaction to use cooling or heating liquid. According requirements in atmospheric pressure or negative pressure mixing reaction, and can do backflow of reaction solution with distillation.
Model : TFD-50L
Capacity : 50L
Power: 370W
Rotating Speed : 100-1400rpm
Mixing Torque 1300r/min :22000g.cm
Glass Kettle Cover : 60#40#/50#/29#
Glass Material: Borosilicate (Pyrex: G3.3)
Frame Material: Stainless Steel
Mouth Amount of Vessle Lid: 4
Vaccum Degree: 0.095Mpa
Machine Size(cm): 100*105*240
Can be customized as requested.



Wooden cases.
Feb-17-11
 
Hydrothermal synthesis reactor, also known as polymerization reactors, digestion tanks, high pressure digestion tank, pressure vessel, reactor, pressure container bombs, digestion tanks, hydrothermal synthesis reactor, experiment reflects the kettle.

Features:
1. Reasonable structure, non-spill of hazardous substances, pollution reduction, safety guarantee.
2. Samples indissolvable under normal conditions and samples containing volatile elements can dissolve quickly in Hydrothermal synthesis reactor without loss.
3. Easy operation and reliable data.
4. Stainless still shell, special PTFE liner, good corrosion resistance.

Model :KH-20
Capacity :20ml
Shell Material :Stainless Steel
Liner Material :Special PTFE
Maxium Working Temperature :230 ¡ãC
Maxium Working Pressure :3Mpa.



wooden cases or as required
4986 Laboratory Equipments Instruments Suppliers
Short on time? Let Laboratory Equipments Instruments sellers contact you.
See what buyers and suppliers are discussing in Laboratory Equipments Instruments import export community