Indications: The 3.5 mm LCP Extra-articular Distal Humerus Plates are indicated for fractures of the distal humerus.
Plate features
Left and right plates are anatomically contoured to match the posterolateral distal humerus.
Two most distal holes are angled toward the capitulum and trochlea.
Plate head tapered to minimize soft tissue irritation.
A limited-contact plate design reduces plate-to-bone contact and helps to preserve the periosteal blood supply.
Anatomic reduction: Fracture reduction and fixation to restore anatomical relationships.
Stable fixation: Fracture fixation providing absolute or relative stability, as required by the patient, the injury, and the personality of the fracture.
Early, active mobilization: Early and safe mobilization and rehabilitation of the injured part and the patient as a whole.
Preservation of blood supply: Preservation of the blood supply to soft tissues and bone by gentle reduction techniques and careful handling.
Plate Features:
Anatomically pre-shaped, twisted design.
Due to Lateral superior placement, there is less need to detach muscles than with anterior placement.
Undercuts reduce impairment of blood supply.
Also used in osteoporotic bone and in multi fragment fractures.
Tapered plate tip facilitates percutaneous insertion and prevents soft tissue irritation.
Indications:
Extra-articular and simple intra-articular distal tibial fractures.
Distal tibial fractures, percutaneous or reducible by limited arthrotomy.
Distal tibial fracture extending into the diaphyseal area.
Plate Features:
These Plates can be anatomically contoured to match with the Distal Medial Tibia.
These plates are designed for both right and left tibia and are available in a variety of lengths.
The head hole allows only 3.5 mm Safty Lock screws, rest holes allow both 3.5 mm Safety Lock and Cortical screws.
Screws : For Combi holes - 3.5 Locking, 3.5 Cortical, 4.0 Cancellous.
For Round Locking Holes - 3.5 Locking, 2.7 or 3.5 Cortical, 4.0 Cancellous.
Complex intra-articular and extra-articular olecranon fractures.
Pseudoarthrosis of the proximal ulna.
Simple olecranon fractures.
Repair of the olecranon after osteotomies in distal humerus surgery.
Plate Features:
Angular stable fixation of fragments regardless of bone quality.
Minimised risk of primary and secondary loss of reduction, even under high dynamic loading.
Reduced impairment of periosteal blood supply due to the limited plate contact.
15007 Wire Cable Harness Wire Mesh Suppliers
Short on time? Let Wire Cable Harness Wire Mesh sellers contact you.
Proximal Tibia Safety Lock Plate 3.5mm is used for Non-unions, Malunions, and fractures of Proximal Tibia, including Simple, Comminuted, Lateral wedge, Depression, Medial wedge, Bicondylar, Combination of Lateral wedge and depression and fractures associated with shaft.
These plates can be anatomically contoured to match Proximal Lateral Tibia.
These plates are designed for both right or left Tibia and are available in a variety of lengths.
The head and three Proximal holes allow only 3.5 mm Safety Lock screws, rest holes allow both 3.5 mm Safety Lock and Cortical screws.
Clavicle Hook Safety Lock Plate 3.5 is indicated for Extra-articular and Intra-articular fractures of Lateral Clavicle .
Anatomically precontoured: The plate facilitates optimal implant placement and surgery to provide an improved outcome.
Rounded shaft profile minimizes the risk of soft tissue irritation between the plate and surrounding soft tissue.
Undercuts in shaft reduce impairment of blood supply.
The plates are designed for both Right and Left Clavicle bones and are available in a varying lengths and Hook depths.
All holes of plate accept 3.5 mm cortex, 3.5mm safety lock and 4.0 mm cancellous screws.
Instrument for 2.7 mm Screws
ST003.01 Drill Bit 2mm 2 nos.
ST203.03 Tap 2.7mm 2 nos.
ST303.00 Tap Handle 1 no
ST503.02 Drill Sleeve : 2mm 1 nos
ST603.02 Tap Sleeve : 2.7mm 1 no
ST113.01 Mini Neutral & Load Drill Guide 1 no
ST403.02 Screw Driver with Sleeve 1 no
ST013.01 Mini Depth Gauge 1 no
ST013.04 Self Retaining Retractor 1 no
ST992.04 Drill Bit (S.S.) : 2.5mm 2 nos.
ST003.02 Drill Bit (S.S. Quick Coupling End) : 2.5mm 1 nos.
ST992.07 Drill Bit (S.S.) 3.5mm 1 no
ST903.02 Counter Sink 1 nos
ST203.04 Cortical Tap : 3.5mm 2 no
ST203.05 Cancellous Tap : 3.5mm 2 no
ST203.06 Cancellous Tap : 4mm 1 no
Locking Proximal Humerus Plate is used for complex and unstable fractures.
Indications
Proximal Humerus
Multifragmentary (dislocated) fractures requiring open reduction
Unstable subcapital fractures
Subcapital pseudarthrosis
Osteotomies
Suture holes The fixation of additional wireloops or sutures attached to the tubercles
(in 3- or 4-fragment fractures) neutralises the muscle tension and helps to maintain reduction.
The head of plate allows only 3.5 mm Safety Lock Screws and shaft of the plate allows both 3.5 mm Safety Lock and Cortical screws.
The multidirectional and angular stable fixation system (TriLock technology) for the distal radius consists of implant plates, implant screws and the corresponding instruments.