Please click here to check who's online and chat with them.

Find Verified Temperature Controllers Indicators Suppliers, Manufacturers and Wholesalers

Top Supplier Cities : Anand   -   New Delhi  
Jun-03-22
 
> 2 x 2-wire, 4~20 mA or 0~10V DC outputs with RTD resistance output option
> Any or both outputs can be assigned to RH or T or Dew point or specific derived physical quantity
> RH & T range selection, parameter configuration and calibration with
> USB to serial converter (DCC501)
> Handheld configurator (HHC202)
> Inbuilt LCD and 3 keys
>. Health / status (Heartbeat) LED

> Calculated physical quantities
-Dew point
-Absolute humidity
-Heat index
-Enthalpy
-Air density

> Isolated RS485 / MODBUS RTU or BACnet MS/TP
> Replaceable RH+T sensor
> Convenient installation with 2-part housing with fixed back and removable electronics
> Stylish housing with vents for air flow across sensor for better accuracy
Sep-26-21
 
XM452 Temperature Humidity Controller for Incubator With Indicators Thermometer Hygrometer Automatic
XM452 Temperature Humidity Controller for Incubator With Indicators Thermometer Hygrometer Automaticpower supply :DC 12V Temperature measurement range:- 40~120? Humidity range?0~100%RH Control precision?0.1? 0.1% RH Test probe?Integrated sensor output:10A delay Size:65*55*28mm
temperature control: 1. Set the temperature + ?Normal display mode, long press the + key for 3 seconds, start temperature numerical flashing, press the + / - key setting values, wrong operation after 5 seconds, automatically return to detect temperature display 2. Set the temperature ?- Normal display mode, long press - button for 3 seconds, stop numerical flashing temperature, press the + / - key set value 3. Restore the factory Settings:- At the same time long press temperature, and humidity
Set the start temperature:Long press the + key, start the flashing temperature, set start temperature by + / - key set Stop temperature:- long press - button, stop flashing temperature, set stop temperature by + / - key
Humidity Settings: Set to start humidity: long-press the + key, start the humidity value flashing, set by + / - key launch humidity value Set stop humidity:- long press - to stop humidity value, set by + / - key to stopping the humidity value Fault code:- display LLL means the sensor fault display HHH mean Test temperature exceeds the range of measurement
Sep-26-21
 
Quick Sense Digital AC 90V 250V Digital Temperature Controller Thermostat

Switch the modes between cool and heat; Control temperature by setting the temperature set value and the different value; Temperature collaboration; Refrigerating control output delay protection; Alarm when the temperature exceeded temperature limit or when sensor error.

Specification and size

Front panel size: 75(L)x34.5(W)(mm)
product size: 75(L)x34.5(W)x85(D)(mm)
Mounting size: 71(L)x29(W)(mm)
Sensor length: 2m(Include the probe)
Technical parameters

Temperature measuring range: -50C~90C
Resolution: 0.1C
Accuracy: +-1 C(-50C~70C)
Power supply: 220VAC 50Hz/60Hz
Power consumption:
Sep-26-21
 
Temperature and Humidity Controller XM-18

Function: 1. Digital displaying of temperature, humidity 2. Full automatic temperature controlling 3. Full automatic humidity controlling 4. Full automatically turning 5. Full automatically alarming 6.Full automatically ventilator 7. Back emergency system
Main Technical Index: 1. Temperature display range: 0 ~ 99.9â?? 2. Temperature measurement accuracy: �± 0.1â?? 3. Humidity display range: 0-99% RH 4. Humidity control accuracy: �± 3% RH
5. Output path: 7 Road ( over-temperature, temperature control, insufficient temperature, egg-left turning, egg right-turning, humidity control, alarm ) 6. The maximum output load current: temperature control, insufficient temperature less = 8A/AC 220V, over-temperature,egg-left turning, egg right-turning, humidity control, alarm less = 1A /AC 220V 7. Number of egg-turning : Maximum record 999 times.
8. Cycle of egg-turning: from 0 to 999 minutes (factory set at 90 minutes) 9. Turn the eggs time: 0 to 999 seconds (factory set at 180 seconds) 10. Ventilation cycle : 0-999 minutes (factory set at 120 minutes) 11. Ventilation time: 0-999 seconds (Factory set at 30 seconds) 12. The measuring line length: 1.5 meters
Working conditions: 1. Power Supply: AC 160V ~ 240V, 50Hz or AC 110V ( choose the one you need ) 2. Relative humidity: less than 85% 3. Ambient temperature: -10 ~ 60â??Digital display of temperature, humidity
Fully automatic temperature controlling
Fully automatic humidity controlling
Automatic turning
Sep-26-21
 
Temperature Humidity Controller XM452
power supply: DC 12V Temperature measurement range:- 40~120? Humidity range?0~100%RH Control precision?0.1? 0.1% RH Test probe?Integrated sensor output:10A delay Size:65*55*28mm
temperature control: 1. Set the temperature + ?Normal display mode, long-press the + key for 3 seconds, start temperature numerical flashing, press the + / - key setting values, wrong operation after 5 seconds, automatically return to detect temperature display 2. Set the temperature ?- Normal display mode, long press - button for 3 seconds, stop numerical flashing temperature, press the + / - key set value 3. Restore the factory
Settings:- At the same time long press temperature, and humidity
Set the start temperature:Long press the + key, start the flashing temperature, set start temperature by + / - key set Stop temperature:- long press - button, stop flashing temperature, set stop temperature by + / - key
Humidity Settings: Set to start humidity: long-press the + key, start the humidity value flashing, set by + / - key launch humidity value Set stop humidity:- long press - to stop humidity value, set by + / - key to stopping the humidity value Fault code:- display LLL mean the sensor fault display HHH mean Test temperature exceeds the range of measurement
793 Temperature Controllers Indicators Suppliers
Short on time? Let Temperature Controllers Indicators sellers contact you.
Aug-10-20
 
Key Specifications/Special Features :
As per customers requirement
Aug-10-20
 
Temperature Indicator
Jun-16-21

200 Capacity Egg Incubator

$328
MOQ: Not Specified
Supplier From Thrissur, Kodakara, India
 
Specifications of 200 Chicken / 480 Quail Egg Incubator
Machine Capacity- 200 Chicken,Duck Eggs/480 Quail Eggs
Watts- 140W
Power Supply- 230V, 5A, 50/60 Hz
Dimensions LBH (Inches)- 37x25x20
Egg Type- Chicken /Duck /480 Quail
Body- Hylum Sheet and Aluminum
Weight- 25Kg
Aluminum Trays- 2 setting Tray
Jun-16-21

100 Capacity Egg Incubator

$246
MOQ: Not Specified
Supplier From Thrissur, Kodakara, India
 
Specifications of 100 Chicken / 240 Quail Egg Incubator
Machine Capacity- 100 Chicken,Duck Eggs/240 Quail
Watts- 140W
Power Supply- 230V, 5A, 50/60 Hz
Dimensions LBH (Inches)- 37x25x15
Egg Type- Chicken /Duck /240 Quail
Body- Hylum Sheet and Aluminum
Weight- 20Kg
Aluminum Trays- 1 setting Tray
Jun-16-21

60 Capacity Egg Incubator

$205
MOQ: Not Specified
Supplier From Thrissur, Kodakara, India
 
Specifications of 60 Chicken / 140 Quail Egg Incubator
Machine Capacity- 60 Chicken,Duck Eggs/140 Quail Eggs
Watts- 140W
Power Supply- 230V, 5A, 50/60 Hz
Dimensions LBH (Inches)- 25x16x15
Egg Type- 50 Chicken ,Duck /170 Quail
Body- Hylum Sheet and Aluminum
Weight- 15Kg
Aluminum Trays- 1 setting Tray
Jan-05-21
 
1. Versions

- PID - Single loop (Includes Onoff Controller and Indicator modes)

- PID - Dual loop

- Heat+cool

- PID - Single loop, 16-segment profile

- VMD

2. IP66 (IEC) / NEMA 4X protection

3. 1 or 2 universal inputs

4. Sampling time 50ms/200ms programmable

5. Upto 6 digital inputs

6. Upto 7 setpoints (2 control relays, 5 alarm relays)

7. Isolated 2 x 0/4~20 mA or 0-10 V DC for control / retransmission output

8. Isolated RS485/Modbus RTU

9. Autotuning function

10. Auto/manual control

11. Calibration & configuration through PC utility

12. User friendly keyboard interface with password protection

13. User key with assignable function
Sep-30-17
Supplier From Ghaziabad, Uttar Pradesh, India
 
The coolant temperature sensor consists of a negative temperature coefficient thermistor that is very sensitive to temperature changes.When the engine coolant temperature gradually increased,Thermistor resistance will gradually decline,On the contrary increases,When the engine coolant temperature changes,The output voltage of the sensor also changes accordingly.
Engine coolant temperature sensor elongated head contact with the cooling liquid,The temperature of the coolant is detected by the change of the resistance value,And this signal is sent to the ECU,Used to detect the engine coolant temperature.The ECU corrects the fuel injection time and the ignition time after receiving the temperature signal.
The normal use of the coolant temperature sensor is -30 ° C to 120 ° C,The corresponding output voltage is 0.3V ~ 4.7V.When the ECU detects an output voltage signal beyond this range,You can determine the sensor circuit failure.


Car intake air temperature sensor (IATS)
Automotive coolant temperature sensor (CTS)
automobile exhaust gas temperature sensor (Ex-haust Air Temperature Sensor, EATS)
car was NTC thermistor / temperature sensor
Car temperature sensor,Respectively, water temperature sensor,Exhaust | intake air temperature sensor,These types of sensors are thermistors with the same characteristics,The temperature coefficient is negative temperature coefficient.The water temperature sensor is mounted on the engine cooling water passage,Its role is to detect the engine cooling water temperature,The water temperature sensor housing is fully enclosed,Use the change of resistance value to detect water temperature.The signal temperature value generated by the water temperature sensor is input to the ECU,ECU according to the cooling water temperature ignition control,Correction fuel injection amount to real-time control of the engine,To ensure the normal operation of the engine under different conditions.
Intake | outlet temperature sensors are installed,Within the housing of the air cleaner box or regulator,The air flow meter or an intake manifold,Used to detect the temperature of the engine inhaled air.As the intake air temperature changes will affect the air density,The hotline, hot film cooling strength and the degree of atomization of the mixture have an impact,Intake air temperature sensor,Provide a signal to correct this effect.
Sep-30-17
Supplier From Ghaziabad, Uttar Pradesh, India
 
The coolant temperature sensor consists of a negative temperature coefficient thermistor that is very sensitive to temperature changes.When the engine coolant temperature gradually increased,Thermistor resistance will gradually decline,On the contrary increases,When the engine coolant temperature changes,The output voltage of the sensor also changes accordingly.
Engine coolant temperature sensor elongated head contact with the cooling liquid,The temperature of the coolant is detected by the change of the resistance value,And this signal is sent to the ECU,Used to detect the engine coolant temperature.The ECU corrects the fuel injection time and the ignition time after receiving the temperature signal.
The normal use of the coolant temperature sensor is -30 ° C to 120 ° C,The corresponding output voltage is 0.3V ~ 4.7V.When the ECU detects an output voltage signal beyond this range,You can determine the sensor circuit failure.


Car intake air temperature sensor (IATS)
Automotive coolant temperature sensor (CTS)
automobile exhaust gas temperature sensor (Ex-haust Air Temperature Sensor, EATS)
car was NTC thermistor / temperature sensor
Car temperature sensor,Respectively, water temperature sensor,Exhaust | intake air temperature sensor,These types of sensors are thermistors with the same characteristics,The temperature coefficient is negative temperature coefficient.The water temperature sensor is mounted on the engine cooling water passage,Its role is to detect the engine cooling water temperature,The water temperature sensor housing is fully enclosed,Use the change of resistance value to detect water temperature.The signal temperature value generated by the water temperature sensor is input to the ECU,ECU according to the cooling water temperature ignition control,Correction fuel injection amount to real-time control of the engine,To ensure the normal operation of the engine under different conditions.
Intake | outlet temperature sensors are installed,Within the housing of the air cleaner box or regulator,The air flow meter or an intake manifold,Used to detect the temperature of the engine inhaled air.As the intake air temperature changes will affect the air density,The hotline, hot film cooling strength and the degree of atomization of the mixture have an impact,Intake air temperature sensor,Provide a signal to correct this effect.
Sep-30-17
Supplier From Ghaziabad, Uttar Pradesh, India
 
Car intake air temperature sensor (IATS)
Automotive coolant temperature sensor (CTS)
automobile exhaust gas temperature sensor (Ex-haust Air Temperature Sensor, EATS)
car was NTC thermistor / temperature sensor
Car temperature sensor,Respectively, water temperature sensor,Exhaust | intake air temperature sensor,These types of sensors are thermistors with the same characteristics,The temperature coefficient is negative temperature coefficient.The water temperature sensor is mounted on the engine cooling water passage,Its role is to detect the engine cooling water temperature,The water temperature sensor housing is fully enclosed,Use the change of resistance value to detect water temperature.The signal temperature value generated by the water temperature sensor is input to the ECU,ECU according to the cooling water temperature ignition control,Correction fuel injection amount to real-time control of the engine,To ensure the normal operation of the engine under different conditions.
Intake | outlet temperature sensors are installed,Within the housing of the air cleaner box or regulator,The air flow meter or an intake manifold,Used to detect the temperature of the engine inhaled air.As the intake air temperature changes will affect the air density,The hotline, hot film cooling strength and the degree of atomization of the mixture have an impact,Intake air temperature sensor,Provide a signal to correct this effect.
Mar-25-14
 
Display
Ø outputs : printout in 4 formats, graphic lcd display & complete analysis data to laptop loaded
With tadma software
Ø type of signal transmission : pulse
Ø control : automatic mode and manual mode





Packaging as per international standards.
Mar-25-14
 
Accessories:
Ø transmitter charger adapter – 1 no.
Ø two core dcdb positive and negative connecting cable - 1 set
Ø transmitter earthing cable – 1 no.
Ø sensor probe small (15 sq mm) – 1 no.
Ø sensor probe big (50 sq mm) – 1 no.
Ø two core connecting cable to connect receiver to sensor probe - 1 set
Ø receiver unit charger – 1 no.
Ø instruction manual – 1 no.

Other models:
Ø digitrace dc 663m - dedicated kit connected to dcdb permanently
Ø digitrace dc 631px- fault location upto 100kΩ


Packaging as per international standards
Feb-05-14
 
We offer micro processor based data display boards. These units comes in 2 ,4 ,6 inch 7 segment led digit sizes. These units are unique with its attractive features. The processor used ensures accuracy, consistency, durability, flexibility to modify its features as per specific customer requirements.
Features include :
•display: 7 segment led display of 2 ,4 ,6 inch size.
•no. Of digits: 4 in each row.
•settings: through wired remote or from computer key pad.
•inputs: sensor ,pfc ,24 vdc ,analogue input. Rs232 ,rs485 etc.,
•output: relay contact ( no-c-nc ),
•communication interface: rs 485/rs 232.
•reset: external ,auto based on preset time.
•supply voltage: 230 ,110 vac
•display color: red ,green ,amber ,yellow ,blue etc., .
Other related products we offer are : .
1.Production display boards – rtc based also
2.Preset part counters, batch and totalizers, length counters etc.,
3.Real time clocks.
S.
Double sided units are also avaliable !
Feb-05-14
 
System description:
Introducing new epa 300, a portable standard meter
Used for the measurement of the three phase power
And the energy. Various measuring features combined with its easy operation concept provide the greatest possible flexibility for a comprehensive testing of metering installations on site.

Features:
1. On line calibration with external ct
2. Direct current option up to 10a
3. Accuracy < 0.2%
4. Large lcd display.
5. Pulse input & output
6. Sensor for pulse out led
Functions:
1. Power and energy measurement of active, reactive and apparent energy
2. Frequency-, phase angle- and power factor measurement.
3. Error measurement on electric meters.

Actual values measurement:
1. Rms values of all voltage and current phases
2. Currents for all 3 phases
3. Frequency and power factor - cos ϕ.
4. 3 phase - kw, kwh, kva, kvar, kvarh
5. Percentage of the measurement error with pulse input.

Technical data:
1. Power supply: 85-250vac, 50/60hz.
2. Voltage measurement: 0……300v
3. Voltage measurement accuracy: < 0.1%
4. Current measurement: 50ma ….10a (for direct measurement)1 a…1000a (for measurement with clip -on ct)
5. Current measurement accuracy: direct measurement <0.1% with external ct <0.2%.
6. Frequency measurement: 40….60hz.
7. Energy accuracy: <0.2%
May-07-13
 
We provide testing service with highly efficient climatic test chambers that create reliably and exactly the climate to your requirements as long and as often as you wish. Optimized, tested basic modules, ensure that the required temperature and climatic test values are complied with even during long term tests. Stability and constant climate tests
• solar
• pharmaceuticals & cosmetics
• battery


Inside dim: w800 x d800 x h950mm
Dec-03-13
 
`nelster' is india's pioneer 7 the largest manufacturer of relay test blocks. `nelster' standards for quality & safety requirements exceed national standards and could be traced to international length standards as is evident from government of india's premier nabl accredited laboratories. For more information please visit

Any quantity.
793 Temperature Controllers Indicators Suppliers
Short on time? Let Temperature Controllers Indicators sellers contact you.
See what buyers and suppliers are discussing in Temperature Controllers Indicators import export community