1 POLE INV.TIME O/C OR E/F RELAY WITH IN
Model No : CDG21AF116ZM(M)
CDG21/CAG17(MRK-III)
APPLICATION - E/F
BURDEN / 1.3 SEC. - 3 VA / 1.3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - 0.1 - 0.4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
HIGH SET TYPE - CAG17
HIGHSET CONTACTS - 2M S/R
HIGHSET E/F SETTING - 1 - 8 Amps.
MOUNTING - FLUSH
Name Plate RFG9125 692
Outline Diagram MFJ 012
Wiring Diagram MADZ821.31
VERIFIED
Jun-14-21
 
Gbcdg21af116znch
Idmt Earth Fault Relay With High Set
Technical Specification
Relay Model Cdg21af116znch
Relay Type Cdg21
Application E/f
Burden 3va
C.t. Secondary 1 Amp Ct.
Case Size 1d V 10t
Contacts (S/r or H/r) 2 N/o 1 N/c H/r
D.m.t 1.3 Sec
E/f or U/v Setting 0.1 to 0.4 a
Flag Yes
Frequency 50 Hz
High Set Type Cag17
Highset Contacts 2m S/r
Highset E/f Setting 1 to 8a
Highset O/c Setting Not Applicable
Mounting Flush
O/c or O/v Setting Not Applicable
Name Plate-1 Rfg9125 692
Outline Drawing Mfj 012
Wiring Diagram Madz821.32
VERIFIED
Jun-14-21
 
ALSTOM GBCDG21AF117ZMCH
IDMT OVER CURRENT RELAY WITH HIGH SET
Relay Model No. CDG21AF117ZMCH
Relay Type CDG21
Size 1D V 10T
Current Setting 2.5 to 10 Amps
Frequency 50 Hz
Application O/C
Contacts 3 N/O S/R
Output Contacts 2 N/O S/R
Taps Std
C.T. Secondary 5 Amps
Burden 3 VA
Operating Time 3 Sec
High-set Contacts 2 N/O S/R
High-set Cur. Setting O/C 5 to 40 Amps
High-set CAG 17
Nameplate RFG9126 674
Outline Arrangement MFJ 012
Wiring Diagram MADZ821.31
VERIFIED
Jun-14-21
 
ALSTOM GBCDG21AF8201SKCH
IDMT EARTH FAULT RELAY WITH HIGH SET CA
Technical specification
Model Number CDG21AF8201SKCH
Relay type CDG21
Case Size 1D S/E
Application E/F S/T
Current Setting 1 TO 4 Amps
Contacts 2 N/O 2 N/C H/R
Output Contacts 2 N/O 2 N/C H/R
Flag Yes
Taps STD
C.T.Secondary 5 Amps
Burden / Operating Time 3 Va / 3 Secs
High Set Contacts 2 N/O S/R
High Set CAG 17
Frequency 50 Hz
High Set Cur.Setting 5 TO 40 Amps
Name Plate RFG9126 796
Outline Drawing MFJ 012
Wiring Diagram MADZ821.33
VERIFIED
Jun-18-21
 
ALSTOM GBCDG21AF8202SKCH
1 POLE INV.TIME O/C OR E/F RELAY WITH IN
Technical specification
Model Number CDG21AF8202SKCH
Relay type CDG21
CASE SIZE 1D S/E
APPLICATION O/C S/T
CURRENT SETTING 2.5 TO 10 AMPS
CONATCTS 2M 2B H/R
OUTPUT CONTACTS 2M 2B H/R
TAPS STD
C.T.SECONTARY 5 AMPS
BURDEN / OPERATING TIME 3 VA / 3 SECS.
HIGH SET CONTACTS 2M S/R
HIGH SET CAG 17
FREQUENCY 50 HZ
HIGH SET CUR.SETTING 12.5 TO 100 AMPS
NAME PLATE RFG9126 774
OUTLINE DRAWING MFJ 012
WIRING DIAGRAM MADZ821.33
793 Temperature Controllers Indicators Suppliers
Short on time? Let Temperature Controllers Indicators sellers contact you.
VERIFIED
Jun-18-21
 
ALSTOM GBCDG21AF9068ZACH
1 POLE INV.TIME O/C OR E/F RELAY WITH IN
Technical specification CDG21AF9068ZACH
Relay type CDG21
CASE SIZE 1D SE
APPLICATION O/C
CURRENT SETTING IDMT 0.5 TO 2 AMPS
C.T.RATING 1 Amp.
CURRENT SETTING HIGH SET 5 TO 20 AMPS
TAP STD
FREQUENCY 50 HZ
BURDEN / OPERATING TIME 3 VA / 3 SECS.
HIGH SET UNIT 2M S/R WITH FLAG
AUX.VOLTAGE 100-125/
220-250V DC
NAME PLATE RFG9126 771
OUTLINE DRAWING MFJ 012
WIRING DIAGRAM MADZ802.58-1
VERIFIED
Jun-18-21
 
GBCDG31EG001SACH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No : CDG31EG001SA(M)
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate RFG9126774
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG001SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Technical Specifications
Model No - CDG31EG001SBCH
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 1 - 4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
NAME PLATE - RFG9126 904
Outline Diagram MFJ 014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG001SCCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No : CDG31EG001SC(M)
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA /3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate RFG9126674
Outline Diagram MFJ014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG001SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG001SD(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 1 - 4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate - RFG9126 904
Outline Diagram MFJ 014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG002SACH
NON DIR.SELF POWER 3 O/C RELAY 2M S/R
TECHNICAL SPECIFICATION
Model No : CDG31EG002SACH
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C OR O/V SETTING - 0.5 - 2 Amps.
Name Plate RFG9126771
Outline Diagram MFJ014
Wiring Diagram MADZ802-63-1
VERIFIED
Jun-18-21
 
GBCDG31EG002SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
MODEL NO - CDG31EG002SBCH
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.5 - 2 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
NAME PLATE - RFG9126 903
Outline Diagram MFJ 014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG002SCCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Technical specification
Relay Model No CDG31EG002SC(M)
Relay type CDG31
CASE SIZE 3D HORZ.
APPLICATION 3 O/C
O/C SETTING 0.5 - 2 Amps
BURDEN / D.M.T 3 VA / 3 SEC.
Taps Std
C.T. SECONDARY 1 AMP CT.
CONTACTS (S/R OR H/R) 2 N/O 2 N/C H/R
FLAG YES
FREQUENCY 50 HZ
MOUNTING FLUSH
Name Plate RFG9126 671
Outline Diagram MFJ 014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG002SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Technical Specifications
Relay model No CDG31EG002SDCH
Relay type CDG 31
Case size 3D H 30T
Application 2 O/C + 1 E/F
Current setting - O/C 2.5 to 10 amps
( 50-200% )
Contacts (S/R OR H/R) 2 N/O 2 N/C H/R
Output Contacts 2 N/O 2 N/C H/R
Taps / Burden Std / 3 VA
C.T.Secondary 5 amps
D.M.T 3 secs
Current setting - E/F 0.5 to 2 amps
(10 - 40% )
Flag / Mounting Yes / Flush
Frequency 50 Hz
Name plate RFG9126 903
Outline Diagram MFJ 014
Wiring Diagram MADZ 802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG003SACH
NON DIR.SELF POWER 3 O/C RELAY 2M S/R
Technical specification
Relay Model No CDG31EG003SACH
Relay type CDG 31
Case size 3D Hor.
Application 3 O/C
Current setting 0.2 to 0.8 amps
Contacts (S/R OR H/R) 3 N/O S/R
Output contacts 2 N/O S/R
Burden / Operating Time 3 VA / 3 Secs.
C.T.Secondary 1 amps
Taps / frequency Std / 50 Hz.
Note:-write in name plate as
over current instead of E/F.
And Erase E/F symbol.
Flag Yes
Mounting Flush
Name Plate RFG9126 793
Outline Diagram MFJ 014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG003SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG003SB(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.2 - 0.8 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
NAME PLATE - RFG9126 902
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG003SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG003SD(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 0.2 - 0.8 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
Name Plate - RFG9126 902
Outline Diagram MFJ 014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG004SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG004SB(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN /D.M.T - 3 VA /3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.1 - 0.4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
Name Plate - RFG9126 901
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG004SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG004SD(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 0.1 - 0.4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
Name Plate - RFG9126 901
Outline Diagram MFJ 014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG011SACH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No : CDG31EG011SA(M)
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 1.3 SEC
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate RFG9125 674
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1