Cat No : 11FK50. Bioline DENGUE NS1 Ag TEST FOR EARLY CLINICAL PHASE OF DENGUE INFECTION
Bioline Dengue NS1 Ag rapid test is an in vitro immunochromatographic assay designed to detect Dengue virus NS1 antigen in human serum, plasma or whole blood.
Product not available in all countries. Please check with your local sales representative regarding availability in your area.
Benefits:
Diagnosis of early acute dengue infection by detecting dengue NS1 antigen
Dengue NS1 antigen can be detected from 1 day after onset of fever
Specimen : Serum, plasma or whole blood (100�¼l)
Test result : 15~20 minutes
Specification:
Sensitivity 92.4%, Specificity 98.4%
Cat No :14FK10 Bioline* Rotavirus test is an immunochromatographic assay for the detection of Group A rotavirus in human fecal specimens. The test utilizes two kinds of antibody in a solid phase sandwitch immunochromatography to detect group specific proteins, including the major inner capsid protein, present in Group A rotaviruses.
â?¢ Early detection of rotavirus antigen group A all serotype
Shelf life and storage temperature: 18 months from the date of manufacturing at1-30 C
Performance: Sensitivity: 94 %, Specificity 98.3 % (vs. RT-PCR)
Cat No : ACKCRDPC3. Product Description : Acon Pregnancy Test Strip (HCG) is a one step pregnancy test kit containing test strip. The urine sample is to be collected in a clean, dry container and almost half test strip should be dropped inside the container. The first urine sample of the day is preferred. The pack insert should be thoroughly read before use. To know how to use and read test results. Acon pregnancy test strip detects pregnancy in just 5 minutes.
Features & Specifications : One Step Pregnancy Test Strip, Easy to Use, Quick Result in just 5 minutes, Pack of 3 Test Strips, For more info, please refer the product pack for usage instructions.
Product Details:
Number of Reactions(Preps)/Kit : 10T
Brand : SD Biosensor
ICMR Approved : Yes
Result Time (Rapid Kits) : 15 min
CAT No : RK013-10
One step, rapid, immunochromatographic test for the detection of IgM/IgG antibodies to four serotypes of dengue virus (DEN-1, DEN-2, DEN-3 and DEN-4) & Dengue virus NS1 antigen in human serum, plasma or whole blood.
Kit Contents:
Standard Q Dengue Ag Ab Duo cassette x 10
Specimen transfer device 10ml x 10
Butter bottle 4ml x 01
Instructions for use x 1
STANDARD Q Dengue Duo test is an immunochromatographic assay for the detection of NS1 antigen and Dengue virus-specific IgM and IgG antibodies in human serum, plasma and whole blood. By detecting the NS1 antigen, not only the initial infection can be detected, but also Dengue virus-specific IgM and IgG can be detected at the same time. Screening test results can be obtained within 15 minutes with high sensitivity and specificity.
Product Details:
Number of Reactions(Preps)/Kit :20T
Brand : SD Biosensor
ICMR Approved : Yes
Result Time (Rapid Kits) : 15min
CAT No : RK012-20
One step, rapid, immunochromatographic test for the detection of Dengue IgMlIgG antibodies to four senatypes of dengue virus (DEN-I, DEN-2. DEN-3 and DEN-4) in human serum, plasma or whole blood.
Kit Contents:
Standard Q Dengue IgM IgG cassette x 20
Specimen transfer device 10ml x 20
Butter bottle 4ml x 01
Instructions for use x 1
STANDARD Q Dengue IgM/IgG qualitatively analyzes IgM and IgG antibodies specific to Dengue virus in serum, plasma and whole blood using immunochromatography. By detecting IgM and IgG specific to Dengue virus, the primary and secondary Dengue virus infections can be discriminated, and the screening test result can be obtained within 15 minutes with its high sensitivity and specificity.
Advantage:
Differential detection of IgG and IgM antibodies
Easy to use, Easy to read and interpret
Room temperature storage
Able to read positive/negative infections fast and accurately with a little amount of sample (10 �µl)
261 Diagnostic Kits Suppliers
Short on time? Let Diagnostic Kits sellers contact you.
Product Details:
Number of Reactions(Preps)/Kit 40T
Brand ; SD Biosensor
ICMR Approved : Yes
Result Time (Rapid Kits) : 15min
CAT No : RK025-40
One step, rapid immunothematographic test for the differential detection between Plasmodium falciparum Histidine- Rich Protein II (HRP II) and Plasmodium species (P. falciparum , P vivax P. ovale, P. malariae) lactate dehydrogenase (pLDH) in human whole blood
Kit Contents:
Standard Q Malaria Pf/PV Ag cassette x 40
Specimen transfer device 3 microlitre x 40
Butter bottle 3m1 x 02
Instructions for use x 01
STANDARD Q Malaria P.f Ag qualitatively analyzes Plasmodium falciparum and Plasmodium vivax antigens in whole blood using immunochromatography. The target antigen is Histidine-Rich Protein II (HRP-II) of Plasmodium faciparum and plasmodium lactate dehydrogenase (pLDH) of Plasmadium vivax, and the screening test result can be obtained within 15 minutes with its high sensitivity and specificity
Advantage:
Distinguish the infection between P.falciparum and P.vivax
Optimized on-site diagnosis with the small diagnostic kit
Able to read positive/negative infections fast and accurately with a little blood (5aul)
Room temperature storage.
Number of Reactions(Preps)/Kit : 40T
Brand : SD Biosensor
ICMR Approved : Yes
Result Time (Rapid Kits) : 15 min
CAT No : RK027-40
STANDARD Q Malaria P.f Ag qualitatively analyzes Plasmodium falciparum and Plasmodium species antigens in whole blood using immunochromatography. The target antigen is Histidine-Rich Protein II (HRP-II) of Plasmodium faciparum and plasmodium lactate dehydrogenase (pLDH) of Plasmadium species, and the screening test result can be obtained within 15 minutes with its high sensitivity and specificity.
Distinguish the infection between P.falciparum and others
Optimized on-site diagnosis with the small diagnostic kit
Able to read positive/negative infections fast and accurately with a little blood (5aul)
Room temperature storage
Number of Reactions(Preps)/Kit: 30T
Brand : SD Biosensor
ICMR Approved : Yes
Result Time (Rapid Kits): 10 min
Country of Origin : Made in India
CAT No : RK026-30
STANDARD Q HBsAg performs qualitative analysis by specifically detecting the surface protein antigens of hepatitis B virus in serum, plasma and whole blood using immunochromatography. With a simple test method, hepatitis B infection can be discriminated early, and with its high sensitivity and specificity, the screening test result can be obtained within 20 minutes.
Easy to use, Easy to read and interpret
Room temperature storage
Performance
Sensitivity : 100% (43/43) / Specificity : 100% (162/162)
Product Details:
Number of Reactions(Preps)/Kit : 20T
Brand ; SD Biosensor
ICMR Approved ; Yes
Result Time (Rapid Kits) : 15 min
CAT No : RK029-20
STANDARD Q TSUTSUGAMUSHI IgM/IgG is a rapid,sensitive,qualitative Immunochromatographic assay for the detection of IgM/IgG antibodies against Orientia Tsutsugamushi in human serum,Plasma or whole blood specimen.it is an initial screening test and this test kit is for in vitro use only by professionals.
Differential detection of IgM & IgG Antibodies
Easy to use,Easy to interpret
Long term storage
Faster results with lesser specimen volume (10aul)
Product Details:
Number of Reactions(Preps)/Kit : 20T
Brand : SD Biosensor
ICMR Approved : Yes
Result Time (Rapid Kits) : 15 min
CAT No : RK024-20
STANDARD Q Chikungunya IgM/IgG qualitatively analyzes IgM and IgG antibodies specific to Chikungunya virus in serum, plasma and whole blood using immunochromatography. Screening test results can be obtained within 15 minutes with high sensitivity and specificity.
Differential detection of IgG and IgM antibodies
Easy to use, Easy to read and interpret
Room temperature storage
Able to read positive/negative infections fast and accurately with a little amount of sample (10 aul)
Product Details:
Number of Reactions(Preps)/Kit : 30T
Brand : SD Biosensor
ICMR Approved : Yes
Result Time (Rapid Kits) : 15 min
CAT No : RK018-30
STANDARD Q HCV Ab qualitatively analyzes antibodies specific to hepatitis C virus in serum, plasma and whole blood using immunochromatography. With a simple test method, hepatitis C infection can be discriminated early, and with its high sensitivity and specificity, the screening test result can be obtained within 5 minutes.
Easy to use, Easy to read and interpret
Room temperature storage
Performance
Sensitivity : 98.9% (92/93) / Specificity : 100% (168/168)
Number of Reactions(Preps)/Kit : 50T
Brand : SD Biosensor
ICMR Approved : Yes
Result Time (Rapid Kits) : 10 min
CAT No : RK022-50
"STANDARD QA Ultra-DotA HIV Test is a rapid, sensitive andqualitative immunochromatographic assay to detect circulatingantibodies against HIV in human serum or plasma. The test is for invitro diagnostic use and is intended as an aid to early diagnosis ofHIV infection. This test is intended for professional use only as aninitial screening test."
Number of Reactions(Preps)/Kit : 50
Brand : SD Biosensor
ICMR Approved : Yes
Result Time (Rapid Kits) : 10 min
CAT No : RK023-50
STANDARD QA Ultra-DotA HCV Test is a rapid, sensitive andqualitative immunochromatographic assay to detect antibodiesagainst HCV in human serum or plasma. This test is for in vitrodiagnostic use and intended as an aid to early diagnosis of HCVinfection in patient with clinical symptoms with HCV infection.The test provides an initial screening result only. More specificalternative diagnosis methods should be performed in order toobtain the confirmation of HCV infection.
Product Details:
Brand : Boditech Med Incorporated
Size : 25 T
Samples : Human serum/plasma/ control
Specimen volume : 75 Microliter
stored at ; 4 - 30 DegreeC
Cat No ; CFPC-44
T3
Assessing to diagnosis & to monitor thyroid diseases(T3)
This test assesses the level of T3 in the blood to diagnose thyroid dysfunction, help to receive appropriate treatment, and help to confirm the treatment effect through periodic measurement.
INTENDED USE :
ichroma T3 is a fluorescence Immunoassay (FIA) for the
quantitative determination of triiodothyronine (total T3) in
human serum/plasma. It is useful as an aid in management
and monitoring of determination of thyroid disorders.
For in vitro diagnostic use only.
PRINCIPLE :
The test uses a competitive immunodetection method.
In this method, the analyte in the sample binds to the
fluorescence labeled (FL) detection antibody in detection
buffer, to form the complex as sample mixture. This complex
is loaded to migrate onto the nitrocellulose matrix, where
the covalent couple of T3 and bovine serum albumin (BSA) is immobilized and interferes with the binding of analyte and fluorescence labeled (FL) antibody. If more analytes exist in the sample, less detection antibodies are accumulated,
resulting in less fluorescence signal.
Product Details:
Brand : Boditech Med Incorporated
Size : 25 T
Specimen : Human serum/plasma/ control
Specimen volume : 75 microliter
stored at 4 - 30 DegreeC.
Cat No : CFPC-26
T4
Assessing to diagnosis & to monitor thyroid diseases(T4)
Thyroxine (T4) is a type of thyroid hormone. An abnormal amount of T4 may indicate thyroid disease. The T4 test measures total T4, including T4 bonded to protein and free T4. A T4 test will help determine what type of problem is affecting the thyroid.
INTENDED USE :
ichroma T4 is a fluorescence Immunoassay (FIA) for the quantitative determination of thyroxine (T4) in human serum/plasma. It is useful as an aid in management and monitoring of thyroid disorder.
For in vitro diagnostic use only.
PRINCIPLE :
The test uses a competitive immunodetection method.
In this method, the target material in the sample binds to the fluorescence (FL)-labeled detection antibody in detector, to form the complex as sample mixture. This complex is loaded to migrate onto the nitrocellulose matrix, where the covalent couple of T4 and bovine serum albumin (BSA) is immobilized on a test strip, and interferes with the binding of target material and FL-labeled antibody. If the more target material exists in blood, the less detection antibody is accumulated, resulting in the less fluorescence signal.
Product Details:
Brand ; Boditech Med Incorporated
Size : 25 T
Samples: human whole blood/serum /plasma
Specimen volume human whole blood/serum/ plasma
stored at 4-30 C
Cat. No. : CFPC-66
Human Chorionic Gonadotropin (�²-hCG)
Distinguish pregnancy and abnormal pregnancy
The IhCG test can be used to confirm pregnancy, the age of the fetus, abnormal pregnancy (ectopic pregnancy), potential miscarriage, and down syndrome.
INTENDED USE :
ichroma -HCG Plus is a fluorescence Immunoassay (FIA) for the
quantitative determination of -HCG in human whole blood/serum
/plasma. It is useful as an aid in management and monitoring of beta
human chorionic gonadotropin (hCG) level in human
For in vitro diagnostic use only.
PRINCIPLE :
The test uses a sandwich immunodetection method; Dried
antibodies in the detector tube, once diluted with the diluent, bind
with antigens in the sample to form antigen-antibody complexes.
These complexes then migrate through the nitrocellulose matrix and
are captured by another sets of immobilized antibodies on the test line.
The more antigens in the sample, the more antigen-antibody
complexes, which leads to a stronger fluorescence signal. This signal
then is interpreted by the reader to display the �²-HCG concentration in
the sample.
STORAGE AND STABILITY :
The cartridge is stable for 20 months (while sealed in the original
aluminum foil pouch) if stored at 4-30 C.
The detector, diluent and sample diluent are stable for 20 months
if stored at 2-8 C.
After the cartridge pouch is opened, the test should be
Product Details:
Brand: Boditech Med Incorporated
Size : 25 T
Samples : human serum/plasma
Specimen volume : 150 Microliter
stored at 4 - 30 DegreeC.
Cat. No : CFPC-22
Thyroid Stimulating Hormone (TSH)
Diagnosing thyroid dysfunction
One needs an adequate level of thyroid hormone. The excessive or insufficient level would cause various abnormalities in human physiology. The TSH test can deliver the required answer about the hormone level in 12 minutes with fingertip blood (US FDA 510k; AFIAS TSH).
INTENDED USE :
ichroma NT-proBNP is a fluorescence Immunoassay (FIA) for the quantitative determination of NT-proBNP in human whole blood/serum/plasma. It is useful as an aid in the diagnosis of persons suspected of having congestive heart failure.
For in vitro diagnostic use only.
PRINCIPLE :
The test uses a sandwich immunodetection method; the detector antibodies in buffer bind to antigens in the sample, forming antigen-antibody complexes, and migrate onto the nitrocellulose matrix to be captured by the other immobilized-antibodies on test strip.
More antigens in the sample will form more antigen-antibody complexes which lead to stronger fluorescence signal by detector antibodies, which is processed by instrument for ichromaâ?¢ tests to show NT-proBNP concentration in the sample.
Product Details:
Brand : Boditech Med Incorporated
Size : 25 Test
Samples : Whole blood
Sample volume : 75 Microliter
Cat No : CFPC-38
Storage Temperature ; 4 - 30 DegreeC
HbA1c
Assessing the level of glycated hemoglobin in the blood
This test is certified by NGSP (National Glycohemoglobin Standardization Program). It helps diabetic diagnosis, treatment, and prognosis by measuring the glycated hemoglobin concentration (%) in a small amount of blood over the past 3 months.
INTENDED USE
ichroma HbA1c is a fluorescence Immunoassay (FIA) for the quantitative determination of HbA1c(Hemoglobin A1c) in human whole blood. It is useful as an aid in management and monitoring of the longterm glycemic status in patients with diabetes mellitus. For in vitro diagnostic use only.
PRINCIPLE:
The test uses a sandwich immunodetection method; the detector antibody in buffer binds to antigen in sample, forming antigen-antibody complexes, and migrates onto nitrocellulose matrix to be captured by the other immobilized-antibody on test strip. The more antigen in sample forms the more antigen-antibody complex and leads to stronger intensity of fluorescence signal on detector antibody. Instrument for ichromaâ?¢ tests displays the content of glycated hemoglobin in terms of percent of the total hemoglobin in blood.
Product Details:
Brand : Boditech Med Incorporated
Size : 25 T
Samples : whole blood/serum/plasma
Sample volume : 75 Microliter
stored at 4 - 30 DegreeC
Cat No i CHROMA PSA-25
Prostate Specific Antigen (PSA)
Screening for the prostate cancer & monitoring the effects of the treatment
This test helps in the early detection of prostate diseases such as enlarged prostate and prostatitis and prostate cancer by quantifying PSA in male blood, as well as observation of treatment effects and monitoring of recurrence.
261 Diagnostic Kits Suppliers