Gbcdg21af116znch
Idmt Earth Fault Relay With High Set
Technical Specification
Relay Model Cdg21af116znch
Relay Type Cdg21
Application E/f
Burden 3va
C.t. Secondary 1 Amp Ct.
Case Size 1d V 10t
Contacts (S/r or H/r) 2 N/o 1 N/c H/r
D.m.t 1.3 Sec
E/f or U/v Setting 0.1 to 0.4 a
Flag Yes
Frequency 50 Hz
High Set Type Cag17
Highset Contacts 2m S/r
Highset E/f Setting 1 to 8a
Highset O/c Setting Not Applicable
Mounting Flush
O/c or O/v Setting Not Applicable
Name Plate-1 Rfg9125 692
Outline Drawing Mfj 012
Wiring Diagram Madz821.32
VERIFIED
Jun-14-21
 
ALSTOM GBCDG21AF117ZMCH
IDMT OVER CURRENT RELAY WITH HIGH SET
Relay Model No. CDG21AF117ZMCH
Relay Type CDG21
Size 1D V 10T
Current Setting 2.5 to 10 Amps
Frequency 50 Hz
Application O/C
Contacts 3 N/O S/R
Output Contacts 2 N/O S/R
Taps Std
C.T. Secondary 5 Amps
Burden 3 VA
Operating Time 3 Sec
High-set Contacts 2 N/O S/R
High-set Cur. Setting O/C 5 to 40 Amps
High-set CAG 17
Nameplate RFG9126 674
Outline Arrangement MFJ 012
Wiring Diagram MADZ821.31
VERIFIED
Jun-14-21
 
ALSTOM GBCDG21AF8201SKCH
IDMT EARTH FAULT RELAY WITH HIGH SET CA
Technical specification
Model Number CDG21AF8201SKCH
Relay type CDG21
Case Size 1D S/E
Application E/F S/T
Current Setting 1 TO 4 Amps
Contacts 2 N/O 2 N/C H/R
Output Contacts 2 N/O 2 N/C H/R
Flag Yes
Taps STD
C.T.Secondary 5 Amps
Burden / Operating Time 3 Va / 3 Secs
High Set Contacts 2 N/O S/R
High Set CAG 17
Frequency 50 Hz
High Set Cur.Setting 5 TO 40 Amps
Name Plate RFG9126 796
Outline Drawing MFJ 012
Wiring Diagram MADZ821.33
VERIFIED
Jun-18-21
 
ALSTOM GBCDG21AF8202SKCH
1 POLE INV.TIME O/C OR E/F RELAY WITH IN
Technical specification
Model Number CDG21AF8202SKCH
Relay type CDG21
CASE SIZE 1D S/E
APPLICATION O/C S/T
CURRENT SETTING 2.5 TO 10 AMPS
CONATCTS 2M 2B H/R
OUTPUT CONTACTS 2M 2B H/R
TAPS STD
C.T.SECONTARY 5 AMPS
BURDEN / OPERATING TIME 3 VA / 3 SECS.
HIGH SET CONTACTS 2M S/R
HIGH SET CAG 17
FREQUENCY 50 HZ
HIGH SET CUR.SETTING 12.5 TO 100 AMPS
NAME PLATE RFG9126 774
OUTLINE DRAWING MFJ 012
WIRING DIAGRAM MADZ821.33
VERIFIED
Jun-18-21
 
ALSTOM GBCDG21AF9068ZACH
1 POLE INV.TIME O/C OR E/F RELAY WITH IN
Technical specification CDG21AF9068ZACH
Relay type CDG21
CASE SIZE 1D SE
APPLICATION O/C
CURRENT SETTING IDMT 0.5 TO 2 AMPS
C.T.RATING 1 Amp.
CURRENT SETTING HIGH SET 5 TO 20 AMPS
TAP STD
FREQUENCY 50 HZ
BURDEN / OPERATING TIME 3 VA / 3 SECS.
HIGH SET UNIT 2M S/R WITH FLAG
AUX.VOLTAGE 100-125/
220-250V DC
NAME PLATE RFG9126 771
OUTLINE DRAWING MFJ 012
WIRING DIAGRAM MADZ802.58-1
236 Temperature Controllers Indicators Suppliers
Short on time? Let Temperature Controllers Indicators sellers contact you.
VERIFIED
Jun-18-21
 
GBCDG31EG001SACH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No : CDG31EG001SA(M)
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate RFG9126774
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG001SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Technical Specifications
Model No - CDG31EG001SBCH
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 1 - 4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
NAME PLATE - RFG9126 904
Outline Diagram MFJ 014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG001SCCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No : CDG31EG001SC(M)
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA /3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate RFG9126674
Outline Diagram MFJ014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG001SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG001SD(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 1 - 4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate - RFG9126 904
Outline Diagram MFJ 014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG002SACH
NON DIR.SELF POWER 3 O/C RELAY 2M S/R
TECHNICAL SPECIFICATION
Model No : CDG31EG002SACH
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C OR O/V SETTING - 0.5 - 2 Amps.
Name Plate RFG9126771
Outline Diagram MFJ014
Wiring Diagram MADZ802-63-1
VERIFIED
Jun-18-21
 
GBCDG31EG002SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
MODEL NO - CDG31EG002SBCH
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.5 - 2 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
NAME PLATE - RFG9126 903
Outline Diagram MFJ 014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG002SCCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Technical specification
Relay Model No CDG31EG002SC(M)
Relay type CDG31
CASE SIZE 3D HORZ.
APPLICATION 3 O/C
O/C SETTING 0.5 - 2 Amps
BURDEN / D.M.T 3 VA / 3 SEC.
Taps Std
C.T. SECONDARY 1 AMP CT.
CONTACTS (S/R OR H/R) 2 N/O 2 N/C H/R
FLAG YES
FREQUENCY 50 HZ
MOUNTING FLUSH
Name Plate RFG9126 671
Outline Diagram MFJ 014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG002SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Technical Specifications
Relay model No CDG31EG002SDCH
Relay type CDG 31
Case size 3D H 30T
Application 2 O/C + 1 E/F
Current setting - O/C 2.5 to 10 amps
( 50-200% )
Contacts (S/R OR H/R) 2 N/O 2 N/C H/R
Output Contacts 2 N/O 2 N/C H/R
Taps / Burden Std / 3 VA
C.T.Secondary 5 amps
D.M.T 3 secs
Current setting - E/F 0.5 to 2 amps
(10 - 40% )
Flag / Mounting Yes / Flush
Frequency 50 Hz
Name plate RFG9126 903
Outline Diagram MFJ 014
Wiring Diagram MADZ 802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG003SACH
NON DIR.SELF POWER 3 O/C RELAY 2M S/R
Technical specification
Relay Model No CDG31EG003SACH
Relay type CDG 31
Case size 3D Hor.
Application 3 O/C
Current setting 0.2 to 0.8 amps
Contacts (S/R OR H/R) 3 N/O S/R
Output contacts 2 N/O S/R
Burden / Operating Time 3 VA / 3 Secs.
C.T.Secondary 1 amps
Taps / frequency Std / 50 Hz.
Note:-write in name plate as
over current instead of E/F.
And Erase E/F symbol.
Flag Yes
Mounting Flush
Name Plate RFG9126 793
Outline Diagram MFJ 014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG003SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG003SB(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.2 - 0.8 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
NAME PLATE - RFG9126 902
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG003SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG003SD(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 0.2 - 0.8 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
Name Plate - RFG9126 902
Outline Diagram MFJ 014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG004SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG004SB(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN /D.M.T - 3 VA /3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.1 - 0.4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
Name Plate - RFG9126 901
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG004SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG004SD(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 0.1 - 0.4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
Name Plate - RFG9126 901
Outline Diagram MFJ 014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG011SACH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No : CDG31EG011SA(M)
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 1.3 SEC
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate RFG9125 674
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG011SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG011SB(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN /D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 1 - 4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate - RFG9125 904
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1