Please click here to check who's online and chat with them.

Find Verified Temperature Controllers Indicators Suppliers, Manufacturers and Wholesalers

Top Supplier Cities : Anand   -   New Delhi  
VERIFIED
Jun-14-21
 
ALSTOM GBCDD21PF060SBCH
DIRECTIONAL IDMT RELAY SELF POWERED
Technical specification
Relay model no CDD21PF060SBCH
Relay type CDD 21
Case size 1.5D S/E
Application E/F
Current setting 0.1 to 0.4 amps
C.T.Secondary 1 amps
Voltage 63.5 / 190V ac
Frequency 50 Hz
Burden 3 VA
Operating time 1.3 secs
M.T.A.I Lead/lag volt-deg 60 - lag
Contacts 3M S/R
Output contacts 2M S/R
Taps Std
Flag Yes
Name plate RFG9125 011
Outline drawing MFJ 013
Wiring diagram MPDZ 801.23
VERIFIED
Jun-14-21
 
ALSTOM GBCDD21PF061SBCH
SELF-POWERED DIR.INV.TIMEO/C ORE/F RELAY
Technical Specifications
Model No : CDD21PF061SB(M)
CDD21(SELF-POWERED)
APPLICATION - E/F
BURDEN - 3VA
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1-1/2D VERT. 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
D.M.T - 1.3 SEC
E/F OR U/V SETTING - 10 - 40% E/F
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
MTA PHASE-CHAR ANGLE - 45 DEGREES
O/C OR O/V SETTING - NOT APPLICABLE
V.T/P.T SECONDARY - 63.5 TO 190V A.C(E/F)
Name Plate RFG9125-011
Outline Diagram MFJ013
Wiring Diagram MPDZ801.23
VERIFIED
Jun-14-21
 
ALSTOM GBCDD21PF062SBCH
DIRECTIONAL IDMT RELAY SELF POWERED
RELAY MODEL CDD21PF062SBCH
CDD21
APPLICATION E/F
BURDEN 3VA
C.T. SECONDARY 1 AMP CT.
CASE SIZE 1-1/2D VERT. 10T
CONTACTS (S/R OR H/R) 2 N/O S/R
D.M.T 1.3 SEC
E/F OR U/V SETTING 10 - 40% E/F
FLAG YES
FREQUENCY 50 HZ
MOUNTING FLUSH
MTA PHASE-CHAR ANGLE 14 DEGREES E/F
O/C OR O/V SETTING NOT APPLICABLE
V.T/P.T SECONDARY 63.5V A.C(E/F)
NAME PLATE-1 RFG9125-011
OUTLINE DRAWING MFJ013
WIRING DIAGRAM MPDZ801.23
VERIFIED
Jun-14-21
 
ALSTOM GBCDD21PF9054BCH
SELF-POWERED DIR. INVERSE TIME O/C OR E/
Technical specification
Relay model no CDD21PF9054BCH
Relay type CDD 21
Case size 1-1/2D Vert.10T
Application E/F
Current setting 0.5 - 2.0 amps
Aux.current or voltage 100 - 250V dc
Burden 3 VA
C.T.Secondary 5 amps
Contacts (S/R OR H/R) 2 N/O S/R
D.M.T 3 secs
Taps Std
Flag Yes
Mounting Flush
Frequency 50 Hz
MTA Phase-char angle 60 Deg
V.T/P.T Secondary 63.5V ac
Name plate RFG9126-042
Outline drawing MFJ 013
Wiring diagram MPDZ 801-10-1
VERIFIED
Jun-14-21
 
Alstom Gbcdd21pf9056ach
Self-powered Dir. Inverse Time O/c or E/
Technical Specification
Relay Model Cdd21pf9056ach
Cdd21
Application O/c
Aux. Current or Voltage 100 - 250 V Dc
Burden 3va
C.t. Secondary 1 Amp Ct.
Case Size 1-1/2d Vert. 10t
Contacts (S/r or H/r) 2 N/o S/r
D.m.t 3 Sec.
E/f or U/v Setting Not Applicable
Flag Yes
Frequency 50 Hz
Mounting Flush
Mta Phase-char Angle 45 Degrees
O/c or O/v Setting 50 - 200%
V.t/p.t Secondary 110v Ac
Name Plate-1 Rfg9126-017
Outline Drawing Mfj013
Wiring Diagram Mpdz801-10-1
236 Temperature Controllers Indicators Suppliers
Short on time? Let Temperature Controllers Indicators sellers contact you.
VERIFIED
Jun-14-21
 
Alstom Gbcdd21pf9058bch
Self-powered Dir. Inverse Time O/c or E/
Technical Specification
Relay Model Cdd21pf9058bch
Cdd21
Case Size 1-1/2d Vert. 10t
Application E/f
C.t. Secondary 1 Amp Ct.
E/f Setting 0.2 - 0.8 Amps
Burden / D.m.t 3va / 3 Secs
Aux.voltage 100 - 250 V Dc
Contacts 2 N/o S/r
Flag Yes
Frequency 50 Hz
Mounting Flush
Mta Phase-char Angle 45 Degrees
V.t/p.t Secondary 63 / 190 V Ac
Tap Std
Name Plate-1 Rfg9126-039
Outline Drawing Mfj013
Wiring Diagram Mpdz801-10-1
VERIFIED
Jun-14-21
 
Alstom Gbcdd21pf9353ach
Dir.idmt O/c Relay 1va 1.3 Secs (Non-std
Technical Specification
Cdd21
Relay Model Cdd21pf9353ach
Case Size 1-1/2d Vert. 10t
Application O/c
C.t. Secondary 1 Amp Ct.
Current Setting 0.5 - 2 Amps
Burden 1 Va
D.m.t 1.3 Sec
Taps Std
Aux.multi Voltage 100 - 125 /220 250 V Dc
Contacts (S/r or H/r) 2 N/o S/r
Flag Yes
Mounting Flush
Mta Phase-char Angle 30 Degrees
V.t/p.t Secondary 110 V Ac
Frequency 50 Hz
Name Plate-1 Rfg9126-017
Outline Drawing Mfj013
Wiring Diagram Mpdz801-10-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDD21PFB2AA5C
DIRECTIONAL IDMT O/C RELAY,3VA 3SEC DMT
Technical specification
Relay model no CDD21PFB2AA5C
Relay type CDD 21
Case size 1.5D S.E 10 T
Application O/C
Current setting 2.5 to 10 amps
Contacts 1 N/O S/R
Output contacts 1 N/O S/R
Flag Mech Flag
Taps Std
C.T.Secondary 5 Amp
Burden/Operating time 3VA / 3 Secs
Nominal Voltage 100/120 V AC
Frequency 50 Hz
Name plate RFG9126 021
M.T.A.I Lead/Lag 45 Deg Lead
Note: Use ZB9016224 (RV1) In Place of RZB9016059
Outline drawing RFJ0070602
Wiring diagram PDZ 001-203
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF001SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No CDG11AF001SACH
CDG11
APPLICATION - O/C
BURDEN / D.M.T - 3VA / 3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - NOT APPLICABLE
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - 2.5-10 Amps.
Name Plate RFG9126674
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF001SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF001SC(M)
CDG11
APPLICATION - O/C
BURDEN / D.M.T - 3VA / 3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - NOT APPLICABLE
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - 2.5-10 Amps.
Name Plate RFG9126 774
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF002SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No CDG11AF002SACH
CDG11
APPLICATION - O/C
BURDEN/D.M.T - 3VA/3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - NOT APPLICABLE
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - 0.5-2 Amps.
Name Plate RFG9126671
Outline Diagram MFJ012
Wiring Diagram MADZ802-63-1
VERIFIED
Jun-14-21
 
GBCDG11AF002SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF002SC(M)
CDG11
APPLICATION - O/C
BURDEN / D.M.T - 3VA / 3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - NOT APPLICABLE
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - 0.5-2 Amps.
Name Plate RFG9126 771
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF003SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No CDG11AF003SACH
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - 1-4 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9126796
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF003SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF003SC(M)
CDG11
APPLICATION - E/F
BURDEN /D.M.T - 3VA / 3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 1-4 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9126 796
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF004SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No CDG11AF004SACH
CDG11
APPLICATION - E/F
BURDEN - 3VA / 3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - 0.5 - 2 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9126-795
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF004SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF004SC(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 0.5 - 2 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9126 795
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF005SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF005SA(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - 0.2 - 0.8 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9126793
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF005SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF005SC(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 0.2 - 0.8 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9126 793
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
GBCDG11AF011SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF011SC(M)
CDG11
APPLICATION - O/C
BURDEN / D.M.T - 3VA / 1.3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - NOT APPLICABLE
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - 2.5 - 10 Amps.
Name Plate RFG9125 774
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF012SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF012SA(M)
CDG11
APPLICATION - O/C
BURDEN / D.M.T - 3VA / 1.3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - NOT APPLICABLE
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - 0.5 - 2 Amps.
Name Plate RFG9125671
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
236 Temperature Controllers Indicators Suppliers
Short on time? Let Temperature Controllers Indicators sellers contact you.