GBCDG31EG011SCCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No : CDG31EG011SC(M)
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate RFG9125 674
Outline Diagram MFJ014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG011SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG011SDCH
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 1 - 4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
NAME PLATE - RFG9125 904
Outline Diagram MFJ 014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG012SACH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No : CDG31EG012SA(M)
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 1.3 SEC
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
Name Plate RFG9125 671
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG012SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG012SB(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.5 - 2 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate - RFG9125 903
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG012SCCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No : CDG31EG012SC(M)
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
Name Plate RFG9125 671
Outline Diagram MFJ014
Wiring Diagram MADZ802.64-1
236 Temperature Controllers Indicators Suppliers
Short on time? Let Temperature Controllers Indicators sellers contact you.
VERIFIED
Jun-18-21
 
GBCDG31EG012SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No CDG31EG012SD(M)
RELAY TYPE CDG 31
APPLICATION 2 O/C + 1 E/F
BURDEN / D.M.T 3 VA / 1.3 SEC.
C.T. SECONDARY 5 AMP C.T.
CASE SIZE 3D HORZ.
CONTACTS (S/R OR H/R) 2 N/O 2 N/C H/R
E/F SETTING 0.5 - 2 Amps.
FLAG YES
FREQUENCY 50 HZ
MOUNTING FLUSH
O/C SETTING 2.5 - 10 Amps.
NAME PLATE RFG9125 903
Outline Diagram MFJ 014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG013SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG013SB(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.2 - 0.8 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
Name Plate - RFG9125 902
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG013SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG013SD(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F U/V SETTING - 0.2 - 0.8 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
NAME PLATE - RFG9125 902
Outline Diagram MFJ 014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG014SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No : - CDG31EG014SB(M)
RELAY TYPE - CDG31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.1 - 0.4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps
Name Plate - RFG9125 901
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-19-21
 
ALSTOM GBCDG31EG014SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG014SD(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 0.1 - 0.4 Amps
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
NAME PLATE - RFG9125 901
Outline Diagram MFJ 014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-19-21
 
ALSTOM GBCDG31EG022SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Technical specification
Relay model no CDG31EG022SB(M)
Relay type CDG 31
Case size 3D HOR.
Application 2 O/C & 1 E/F
Current setting - O/C 1 to 4 amps
Contacts 3M S/R
Output contacts 2M S/R
Taps / C.T.Secondary STD / 5 amps
Burden 3 VA
Flag Yes
Operating time 3 secs
Current setting - E/F 0.5 to 2 amps
Frequency 50 Hz
Name plate RFG9126 796
Name plate - 1 RFG9126 795
Outline drawing MFJ 014
Wiring diagram MADZ 802.63-1
VERIFIED
Jun-19-21
 
ALSTOM GBCDG31EG604SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Technical Details
RELAY TYPE - CDG 31
Model No - CDG31EG604SBCH
Application - 2 O/C + 1 E/F
Case Size - 3D HORZ.
C.T. Secondary - 1 Amp
O/C Setting - 0.5 - 2 Amps.
E/F Setting - 0.1 - 0.4 Amps.
Burden /D.M.T - 3 VA /3 Sec.
Taps - Std
Contacts - 3 N/O S/R
Output Contacts - 2 N/O S/R
Flag - Yes
Frequency - 60 Hz
Mounting - Flush
Write in Name Plate As 60 Hz instead of 50 Hz.
Name Plate - RFG9126 901
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-19-21
 
GBCDG31EG8101KCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
Model No : CDG31EG8101K(M)
CDG31S/T
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C OR O/V SETTING - 2.5 -10 Amps.
Name Plate RFG9126 774
Outline Diagram MFJ014
Wiring Diagram MADZ821-17
VERIFIED
Jun-19-21
 
GBCDG31EG8101LCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
Model No - CDG31EG8101L(M)
RELAY TYPE - CDG31S/T
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 1 - 4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate - RFG9126 904
Outline Diagram MFJ014
Wiring Diagram MADZ821-17
VERIFIED
Jun-19-21
 
ALSTOM GBCDG31EG8102LCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
Model No : - CDG31EG8102L(M)
RELAY TYPE - CDG31S/T
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 0.5 - 2 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate - RFG9126 903
Outline Diagram MFJ014
Wiring Diagram MADZ821-17
VERIFIED
Jun-19-21
 
ALSTOM GBCDG31EG8106LCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
Relay model no CDG31EG8106LCH
Relay type CDG31
Case Size 3D Hor
Application 2 O/C & 1 E/F
C.T.Secondary 5 Amps
Current Setting - O/C 2.5 TO 10 Amps
Current Setting - E/F 1 TO 4 Amps
Contacts 2 N/O 2 N/C H/R
Output Contacts 2 N/O 2 N/C H/R
Taps STD
Burden / Operating Time 3 Va / 3 Secs.
Frequency 50 Hz
Name Plate RFG9126 904
Outline Drawing MFJ 014
Wiring Diagram MADZ821.42
VERIFIED
Jun-19-21
 
ALSTOM GBCDG31EG8111KCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
RELAY MODEL CDG31EG8111KCH
APPLICATION 3 O/C
BURDEN / D.M.T 3 VA / 1.3 SEC.
C.T. SECONDARY 5 AMP C.T.
CASE SIZE 3D HORZ.
CONTACTS (S/R OR H/R) 2 N/O 2 N/C H/R
FLAG YES
FREQUENCY 50 HZ
MOUNTING FLUSH
O/C SETTING 2.5 - 10 Amps.
NAME PLATE-1 RFG9125 774
OUTLINE DRAWING MFJ014
WIRING DIAGRAM MADZ821-17
VERIFIED
Jun-19-21
 
ALSTOM GBCDG31EG8111LCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
TECHNICAL SPECIFIFICATION
Model No : CDG31EG8111LCH
CDG31S/T
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 1 - 4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps
Name Plate - RFG9125 904
Outline Diagram MFJ014
Wiring Diagram MADZ821-17
VERIFIED
Jun-19-21
 
ALSTOM GBCDG31EG8112LCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
TECHNICAL SPECIFICATION
Model No : - CDG31EG8112LCH
RELAY TYPE - CDG31 AC S/T
APPLICATION - 2 O/C + 1 E/F
C.T. SECONDARY - 5 AMP C.T.
O/C SETTING - 2.5 - 10 Amps.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 0.5 - 2 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
BURDEN / D.M.T - 3 VA / 1.3 SEC.
TAPS - STD
Name Plate - RFG9125 903
Outline Diagram MFJ014
Wiring Diagram MADZ821-17
VERIFIED
Jun-19-21
 
ALSTOM GBCDG31EG8114LCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
TECHNICAL SPECIFIFICATION
Model No : CDG31EG8114LCH
CDG31 Ac Series Trip
Application - 2 O/C + 1 E/F
Case Size - 3D Horz
C.T. Secondary - 1 Amp
Burden / D.M.T - 3 Va / 1.3 Sec
O/C Setting - 0.5 - 2 Amps
Tap - Std.
E/F Setting - 0.1 - 0.4 Amps
Contacts - 2 N/O 2 N/C H/R
Flag - Yes
Frequency - 50 Hz
Mounting - Flush
Name Plate - RFG9125 901
Outline Diagram MFJ014
Wiring Diagram MADZ821-17