1. General
VS1 12KV vacuum circuit breaker VCB
HVD1-12(VS1-12) type indoor AC HV vacuum circuit breaker VCB (hereinafter referred to as circuit breaker) are suitable for 12kV air-insulated indoor switchgears, used as protection and control unit of power equipment of industrial& mining enterprise. Due to the super excellence, it is especially for location where requires the frequent operation of rated working current or multi breaking short circuit current.
The circuit breaker adopts the integrated design of operating mechanism and circuit breaker body, servers as not only fixed installation, but also the handcart unit through equipping with a special propelling mechanism.
2. Service conditions
3.1 Environment temperature:-15degree~+40degree;
3.2 Environment humidity: Daily average relative humidity:
1. Introduction
HVD7 33KV 36kv outdoor HV AC vacuum circuit breaker VCB has many visual advantages like reasonable design, fashionable appearance, high safety and reliability, simple maintenance, long electric life. It is the ideal upgraded products of 35KV outdoor oil circuit breakers.
HVD7-40.5 vacuum circuit breaker is applicable for three-phase power system of AC 50HZ.It is used to make and break the load current ,overload current and short-circuit current.
2. Applicable environment
3.1The ambient temperature should be -30degree~ +40degree(-40degree in the frosty area);
3.2Altitude should not exceed 2000m(over 2000m is plateau type);
3.3The wind pressure should not exceed 700Pa(equal to wind speed 34m/s);
3.4Air pollution degree: 3,that of antifouling type:4;
3.5The installation site should be free from the fire, explosion, chemical corrosion and serious vibration.
1. Main technical parameters
Rated voltage: 33kv 36KV
1 minute power frequency withstand voltage, dry test: 95 kv
1 minute power frequency withstand voltage, wet test: 80 kv
Lightning impulse withstand voltage(peak value): 185 kv
Rated current: 1600A / 2000A
Rated short-circuit breaking current: 20KA, 25KA, 31.5KA
Rated short-circuit making current(peak): 50KA, 63KA, 80KA
Rated operating sequence: O-0.3s-CO-180s-CO
Rated short-time withstand current: 20KA, 25KA, 31.5KA
Rated peak withstand current: 50KA, 63KA, 80KA
Rated short-circuit duration: 4 s
Rated control voltage: AC220,110;DC220,110
Rated short-circuit breaking current break times: 20 times
Full-break time:
1. General
HVD32 ZW32 This vacuum circuit breaker VCB is three-phase AC 50Hz, rated voltage 12 kV outdoor high voltage switch equipment. It is mainly used to opening(closing) load current, overload current and short-circuit current. It is suitable to protect or control the city or village electrical power distribution system.
2 . Main technical parameter
Rated voltage: 12 kv
1 minute rated power frequency withstand voltage: Phase to Phase, to Ground 42 kv / Fracture 48 kv
Rated current: 630A / 1250A
Rated short circuit breaking current: 12.5KA, 16KA, 20KA / 25KA
Rated short-circuit current (peak): 31.5KA, 40KA, 50KA / 63KA
Rated peak withstand current: 31.5KA, 40KA, 50KA / 63KA
4s rated short time withstand current: 12.5KA, 16KA, 20KA / 25KA
Rated operating sequence: O-0.3s-CO-180s-CO(Electric operation)
Closing time: 30-60 ms
Opening time: 20-40 ms
Rated short circuit breaking current breaking times: 30 times
Mechanical life: 10,000 times
Secondary circuit 1 minute power frequency withstand voltage: 2000 v
Energy storage motor rated power: 40 w
Energy storage motor rated voltage V: DC220/110
Rated closing operation voltage v: DC220/110, AC220/110
Rated switching operation voltage v: DC220/110, AC220/110
Electric energy storage time: =8 s
Our MCB is an automatically operated electrical switch. Miniature circuit breakers are intended to prevent damage to an electrical circuit as a result of excess current. They are designed to trip during an overload or short circuit to protect against electrical faults and equipment failure.
Residual Current Circuit Breaker or RCCB is basically a gadget that senses current and disengages any low voltage (uneven current) circuit whenever a fault occurs. The main purpose of installing a Residual Current Circuit Breaker fundamentally is to protect people from electric shocks or death caused by them.
1115 Electric Circuit Breakers Suppliers
Short on time? Let Electric Circuit Breakers sellers contact you.
The 10KA MCB features an elegant and distinctive design, offering dual protection against both short-circuits and overloads.
Feature of JVM66-63-C 10ka MCB
Notable for its fine and distinctive appearance.
Provides dual protection against both short-circuits and overloads.
Boasts an impressive high-breaking capacity of 10KA, surpassing similar products worldwide.
Features a distinct label and a transparent window for added convenience.
Offers a convenient and dependable installation method.
Specification of JVM66-63-C 10ka MCB
Model: JVM66-63-CPole No.:1P, 2P, 3P, 4P
Rated current:1,2,3,4,6, 10,13,16ï¼?20,25,32,40,50,63ARated working voltage:240/415V
Rated frequency: 50/60Hz
Rated frequency (miniature circuit breaker):400VCurve (miniature circuit breaker):B,C,D
High short-circuit breaking capacity:10000A(10KA)
lnstantaneous tripping current:5In (B type)10In (C type) 20In (D type)
Instantaneous non-tripping current:3In (B type) 5In(C type)10ln(D type)Mechanical life:10000 times
Degree of protection: IP20wiring mode:Front wiring
Connecting conductor:Up to and including 16m2Wiring height:21.5mm
Miniature Circuit Breaker Automatic Assembly and inspecting line
MCB Automatic Assembly and inspecting line
Keyword: Miniature Circuit Breaker Automatic Assembly, Miniature Circuit Breaker, Automatic Assembly line, Assembly Machine, Assembly Production Line
Product Introduction
Basic operation process:
ï?¼Loading by AGV robots, printing QR codes based on the product work order issued by the SAP system, and then separating the upper and lower shells.
ï?¼Bottom coating of the upper shell: The installation of three components is completed through ten processes, and after each assembly is completed, there is a corresponding installation accuracy testing process to ensure that the assembly is completely qualified.
ï?¼Installation of lower shell components, upper and lower shell assembly: A total of 25 processes are used to install 12 components. After each part is assembled, guide pins are used to ensure the upper and lower assembly. After the installation of internal components is completed, the product's on/off function is tested. After passing the test, rivets are installed, pressed again, and the screws are removed. All installations are checked, and after passing the test, they are transferred to the inspection station.
ï?¼Unipolar products undergo instantaneous detection, delay detection, cooling tower and other unit inspections, and are then labeled with QR codes and covers before being transferred to the next workstation.
ï?¼Multi pole products require 9 steps of multi pole assembly, and after assembly, a second delay is performed to verify the stability and reliability of the product
ï?¼Finally, it is transferred to the automatic packaging unit through pressure resistance testing, transfer printing, laser labeling, and buckle installation.
The specific parameters:
(1) Equipment input voltage: 220V �± 10%, 50Hz;
(2) The equipment has functions such as automatic shell loading, lid opening, assembly of arc extinguishing plates, magnetic guide plates, handle springs, base springs, positioning pins, handles, jump buckles, locks, coil components, iron core components, wiring columns, adjustment screws, arc extinguishing covers, CCD recognition, lid closing, identification of qualified and unqualified products, assembly of cutting processes, online detection, real-time monitoring, component life monitoring, data storage, MES system and ERP system networking, parameter arbitrary formula, smart energy analysis and energy-saving management system, intelligent equipment service big data cloud platform, etc.
(3) Theoretical production effeciency: 2 seconds per unit; Daily production of approximately 14400 pieces/8 hours;
(4) This device has the function of power-off to save data for 30 days, making it easy to manage production data;
(5) This device adopts touch screen operation, has a computer communication interface, and printing function
Elevate your electrical system's safety and reliability with our Immersed Circuit Breaker. Designed for optimal performance, this advanced circuit breaker is immersed in a dielectric fluid, providing efficient cooling and superior interruption capabilities. Whether you're safeguarding industrial equipment or enhancing the protection of your power distribution network, our Immersed Circuit Breaker is the solution for robust and dependable circuit interruption.
Advantage
1. Better temperature stability, can work stably at -15â??-100â??
2. Nanocrystalline core has high permeability, low coercivity and low loss
3. Sensitive to weak leakage current, with good resistance to large current impact
80% High Color Rendering Index
Perfect Thermal Control with One body Diecasting Aluminum Housing
Ultra-slim and light solution
Adopting a temperd glass preventing from external shock
High reliability with internal SMPS or AC direct drive IC
Perfect solutions for wall washer, parking lot, tunnel light and high mast lights
HVD8 /LW8-40.5 type outdoor high-pressure sulfur hexafluoride circuit breaker is three-pole ac 50 hz, outdoor high voltage switch equipment, applicable to 40.5 kV power transmission and distribution system control and protection, can also be used to contact circuit breaker and movable capacitor group.
Introduction
The LWâ?¡-252/4000-50 self-extinction Ac circuit breaker which is outdoor type finds its universal range of applications for the electrical system with elevation not greater than 2000m, ambient temperature not lower than-30C, dirtiness grade not higher than IV, alternating current 50Hz and the maximum voltage 126kV. It is used for cutting the rated current, malfunction current or switching the circuitry, to control and protect the electrical system, and it can also be used for connecting with the circuit breaker
The gas of the SF6 is employed as the arc-extinguishing medium and the dielectric material. The self-extinction technology and the new-type spring operating mechanism are introduced in the SF6 circuit breaker. Thus the circuit breaker has good qualities with long electrical life, low operation power, lower noise, high reliability, simple structure, small and long overhaul periods. It can fully replace the import same type one.
Caracteristic of structure
The breaker introduces the three-phase porcelain -pole with single interrupter structure. A spring operating mechanism is supplied and the mechanical action of the three-phase is inner connected. The gas of the SF6 is connected in the three-phase pole parts. A density controller with temperature compensation is used to monitor the gas of the SF6. Because of the self-extinction arc control principle and optimized design, it improves the efficiency of mechanism and reduces the operating power
Excellent breaking performance and long electrical life
High mechanism reliability and can be operated frequently
Because of the high insulation intensity and excellent contact movement, the breaking capacity current will not re-burn
The circuit breaker has high outer insulation level and ratio creepage distance is greater than. So it has excellent performance of resisting the filth and the earthquake, it is also can be operated safely under the environment with atrocious weather
High carrying ability: it has high capability margin as the temperature of each contact rises when it is under temperature rise test in the circuit (1.2 times 0f 4000A)
The appearance of the breaker is compact, and the installation and debugging is very easy. The maintenance is also very convenient
VED-12 series indoor high voltage vacuum circuit breaker is suitable for 12kV air-insulated indoor switchgear, used as protection and control unit of power equipment of industrial & mining enterprise. Due to the super excellence, it is especially suitable for locations where requires the frequent operation under rated working current or multiple breaking under short circuit breaking current. The circuit breaker adopts the integrated design of operating mechanism and circuit breaker body, servers as not only fixed installation, but also draw-out type equipped with a special propelling mechanism.
VED-12 has two main types. One is Draw-out type. Model No. is VED-12D. The other is Fixed type. Model No. is VED-12F.
Service conditions
1 Environment temperature:-15°C~+40°C;
2 Environment humidity: Daily average relative humidity:â?¤95%, monthly average relative humidity:â?¤90%; Daily average saturated vapor pressure:â?¤2.2Ã?10-3Mpa,monthly average saturated vapor pressure:â?¤1.8Ã?10-3Mpa;
3 Altitude: Not exceed 1000m;
4 Earthquake intensity: Not exceed°ree;
5 Service location: No water, flammable or explosive matter, chemical corrosive gas or drastic vibration.
Vacuum Circuit Breaker HVD7 40.5KV 1250A outdoor HV AC VCB from Hubei JUCRO Electric
1. Introduction
HVD7 40.5KV 1250A outdoor HV AC vacuum circuit breaker VCB has many visual advantages like reasonable design, fashionable appearance, high safety and reliability, simple maintenance, long electric life. It is the ideal upgraded products of 35KV outdoor oil circuit breakers.
HVD7-40.5 1250A vacuum circuit breaker is applicable for three-phase power system of AC 50HZ.It is used to make and break the load current ,overload current and short-circuit current.
2. Applicable environment
2.1The ambient temperature should be -30degree~ +40degree(-40degree in the frosty area);
2.2Altitude should not exceed 2000m(over 2000m is plateau type);
2.3The wind pressure should not exceed 700Pa(equal to wind speed 34m/s);
2.4Air pollution degree: 3,that of antifouling type:4;
2.5The installation site should be free from the fire, explosion, chemical corrosion and serious vibration.
Vacuum Circuit Breaker VCB HVD32 12KV 630A VCB from Hubei JUCRO Electric
1.General
HVD32 12KV This vacuum circuit breaker VCB is three-phase AC 50Hz, rated voltage 12 kV outdoor high voltage switch equipment. It is mainly used to opening(closing) load current, overload current and short-circuit current. It is suitable to protect or control the city or village electrical power distribution system.
1115 Electric Circuit Breakers Suppliers
Short on time? Let Electric Circuit Breakers sellers contact you.