Field circuit breakerHPB45M-82S DS4 Steam turbine parts
YOYIK is a research and development, production, sales, import agents in one of the manufacturing and processing enterprises. Our company was established in 2004. For more than 20 years, our company's products are widely used in electric power, petroleum, chemical, environmental protection, refractory materials, metallurgy, fire fighting equipment, natural gas, electronics, nuclear industry and other fields. Our company is willing to work with colleagues from all walks of life at home and abroad wholeheartedly cooperation to create a better future! Deyang YOYIK power plant, steel spare parts are as follows:
Need more products for power plant? Contact YOYIK now if you don't know where to search a product.
#DF-Field circuit breakerHPB45M-82S DS4-DF
Element Oil filter SFBX-1000*3
hydraulic filter equivalents WY800*10Q2
oil filter machine price HX-40*5W
Brake Switch RC861CZ090HY994
Quick closing oil solenoid valve 4WE6Y-L6X/EG110NZ4-V/B08
oil press machine with filter TCR.4188931009
ELECTRO HYDRAULIC SERVO VALVE SV4-20 (15)57-80/40-10-S451
Bellows valves 65FWJ1.6P
Thermocouple TE-112
large flow filter element
oil filter making machine CZX.PH-40*5Q3
hydraulic filter breather LQ242S.0
hydraulic oil filter remover TZX2I-10*20Q2
STEM TP3Y601-3
solenoid valve thermostat 4WE6EL6X/EG24NZ5L/V
china cartridge filter DZ903EA10V/-W
Oil level gauge UHC-DB
china cartridge filter NLX-40*10
hydraulic line filter element XU-A100*30S
oil and filter change cost GP600*3Q2
lcd speedometer D421.31U2
hydraulic spin on return line filter Q2U-H100*20S
Seal kits of stop valve DFJ50-1.6P
sensor rpm CS-3-M16-L220
hydraulic filter assy HP8314L39-3MB
Coupling of screw pump HSNS210-54NZ
oil and filter change cost CFRI-630*30Q2
Filter element SFX-330*30
filter ZCL-I-450B
Heavy Sealant Injector KH-35
Yoyik Speed card IMFCS01
electric hydraulic pump 70YB-45
air purifier replacement filter 0508.1411T1201.AW016
filter element cartridge YQUX-40*10
hydraulic filter and housing CFF2-515*180
pt100 temperature transmitter WZP2-001
Field circuit breakerHPB45M-82S DS4
hydraulic filter dimensions ZU-H250*10FS
Solenoid valve directional valve 4WE10Y31B/CW220-50N9Z5L
oil filter making machine DS103EA100VI-W
EH oil main pump discharge filter (EH oil pump ) AP3E301-01D03V/-W
oil filter service YWU-63*180-J
Condition New
Power Source Electric
Features Durable, Easy To Fir, High Performance, Stable Performance, Water Proof
Warranty 3years
Applications Industrial
Puncture Voltage 100-200V, 300-400V, 500-600V, 700-800V
MOCB, ACB, SF6 CB, Vacuum CB, High Voltage Circuit Breakers
1115 Electric Circuit Breakers Suppliers
Short on time? Let Electric Circuit Breakers sellers contact you.
The Bit Breakers are suitable to make up or break out the drilling bit during the oil well drilling and repairing operations. The Users should be chosen the bit breaker according to the size and model of the drilling bit.
Feature:Improve support and retention
Advantage:Manage the magnitude cutter loading and bit torque
Benefit:Improved bit durability and directional responsiveness
Advantage:Higher nozzle counts and/or fixed ports to best serve cleaning,cooling and cuttings evacuation requirements with available hydraulic flows.Allow for higher flow rates with minimal increase in pump pressure.
2. Detailed introduction to Bit breaker
1) Bit breaker is mainly used to screw on or off a rock bit to the bottom of drill string.
2) It can also prevent the rock bit from dropping into well hole.
3) The price of it is cheap and the use of it is safety and reliable.
4) It is easy to operate. First, the bit breaker is placed on well hole and then put the rock bit onto it. Turn it to screw on or off the bit by turnplate.
Automatic circuit breaker tester UPA-3 is designed for testing and ampere-second characterization of automatic AC current circuit breakers. The device allows registering the value of the supplied current and timing the automatic circuit breaker switching interval.
Circuit breaker tester UPA-3 is a mobile device, which could be easily transported to a required testing location.
Circuit breaker tester UPA-3 operates on the principle of varying the power in the primary circuit of the matching power transformer and, respectively, varying the output current, flowing through the automatic circuit breaker under the test. Power regulation could be done either through an external regulator (RNO or VR) or through a built-in thyristor controller.
Cw magnetron glcwm-100l(t)
Glcwm-100l is fixed-frequency cw magnetron, mainly used in microwave heating and plasma generators.
Glcwm-100l has the following features:
Metal ceramic structure, good strength, suitable for industrial application
Special cathode, insurance of long life
Special device for the internal cathode terminal, minimize the microwave leakage.
Operating frequency : 915mhz minimum output : 100kw
High efficiency high flux density carbon infrared heating lampscarbon medium wave infrared lamps features: wavelength range of carbon red heating ir heater: 2.5-2.7 um. cross sectionof carbon red heating ir heater: 33*15mm twin tube diameter.Applied industry: printing painting drying, powder coating drying, paint drying, plastic heating and drying, thin film strecthing, etc.Carbon red heating ir heater model cfir332620wlamp model: cfir332620wquartz tube: white coatinglamp length: 2620mmactive length:2500mmvolatge:400vpower: 6250wcable length: 500mm one side outcolor temperature: 1800-2400kwavelength of ir radiation: 2.5-2.7umcarbon red heating ir heatermax heated length 3200mmmax total length 3400mm;max power output: 9000-12000w;max voltage: 600v;average lifetime of carbon red heating ir heater: 10, 000 hourspart no. voltagewattagetwin tubetotal
transparent high purity quartz heater tube transparent high purity quartz heater tube is one of infrared heating element, which is the most efficient and mostenergy-saving type in the heating area. It can not only improve your heating speed by higher power, but also it will help you save more enrgy by using the shortwave infrared heater to replace the other heaters. transparent high purity quartz heater tubelamp model: swir-10500tube coating: golden reflectorlamp length: 500mmactive length: 440mmvolatge: 220vpower: 800wcable length: 600mmcolor temperature: 2000-2700kwavelength of infrared radiation: 0.75-1.4um ir benefits and features long lifemore than 5000h high speedwithin 1 second to switch onhigh efficiencymore than 85% heat efficiency of full powerhigh power densityup to 200w/cmhigh control abilityneither ballast nor special circuits are necessary for basic usageno air droughtsbecause of radiation(like solar energy)clean and odorlessno risk of contamination over environment or target object to be heatedextensive assortmentmany types of voltage, wattage, length, base, cables, horizontal
Ishcanto ixd47-63 series miniature circuit breaker is made of plastic shell, operating mechanism, contact arc system, tripping mechanisum and other components. The shell is made of high-strength special plastic, with strong impact capability and light wieght.
Feature: short circuit protection
Isolation function
Overload protection
Control
Product Description :
Modular Circuit Breakers - xC60. Breaking Capacity as per IEC 60947-2, Icn = 15kA, upto 40A, Higher Installation Life : Energy limitation class: 3, Tropicalization: T2 - relative humidity 95% at 55C. Higher performance by Low cost : Cascading. Increase system continuty : Discrimination. Reference Temperature of 50C as per IEC60947-2.
Product Specification:
Brand - Schneider
Model Name - A9N2P01C
Current Rating - 1A
Pole - Two Pole
Rated operational voltage - 100V - 125V DC, 240V AC 50/60 Hz, 380V - 415V AC 50/60 Hz
Rated service breaking capacity - 6kA conforming to EN/IEC 60947-2, 100V - 125V DC, 7.5kA conforming to EN/IEC 60947-2. 380V - 415V AC 50/60Hz
Mcb range offer the possibility to select among different characteristics (b, c, d), configurations (1p, 1p+n, 2p, 3p, 3p+n, 4p), breaking capacities (up to 15 ka) and rated currents (up to 125a).
Miniature circuit breakers protect installations against overload and short-circuit, warranting reliability and safety for operations. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the magnetic tripping mechanism for short circuit protection.
ï?? Extra-wide and complete range of MCBs to cover most applications and markets
ï?? Meeting worldwide standards
ï?? Certificates, documentation, training or background information to support customers due to their daily work
ï?? Space and time saving thanks to frame degree updates
Main features
MCB range offer the possibility to select among different characteristics (B, C, D), configurations (1P, 1P+N, 2P, 3P, 3P+N, 4P), breaking capacities (up to 15 kA) and rated currents (up to 125A).
Compliance to the worldwide standards,
IEC/EN 60898-1
IEC/EN 60947-2
IEC/EN 60947-3
IEC/EN 61009-1
GB10963.1
GB1096.1
GB14048.2
GB14048.3
GB16917.1
Allowing the use for residential, commercial and industrial applications 25 mm2 and 10 mm2 cylinder lift twin terminals for challenging industrial use. Cross Real contact position indication, directly connected to the moving contact, for more comfort and safety
ï?? Environmental
Ambient Air Temperature: Operation -5 ... +55°C Storage -40 ... +70 °C
Resistance to Shock acc. to IEC 60068-2-27: 30g / 2 shocks / 13 ms
Resistance to Vibrations acc. to IEC 60068-2-6: 5g, 20 cycles at 5 ... 150 ... 5 Hz
Environmental Conditions: 28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 %
Technical Standards: IEC/EN 60898-1
Rated Current (In): 6A, 10A,16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 125A
Rated Operational Voltage: acc. to IEC 60898-1 230 V AC & 400V AC
Rated Insulation Voltage (Ui): acc. to IEC/EN 60664-1 440 V
Rated Frequency (f): 50 Hz 60 Hz
Rated Ultimate Short-Circuit Breaking Capacity (Icu): (230V AC & 400V AC) 15 kA
Rated Service Short-Circuit Breaking Capacity (Ics): (230V AC & 400V AC) 6 kA
Instantaneous release: Type C: Lighting protection ; Type D: Motor protection
1.General
HVD85 ZN85 33kv 36KV indoor vacuum circuit breaker VCB is suitable for three-phase AC power system of 50Hz and 36kV, used to make and break the load current, overload current and fault current in industrial and mining enterprises, power plants and transformer substations, meanwhile, it is suitable for the occasion where the frequent operation is required.
2. Service conditions
2.1The ambient air temperature should be -15?~40?, the daily average temperature should not exceed 35?.
2.2 Daily mean relative humidity should not exceed 95%, and the daily mean vapor pressure should not exceed 2.2kPa; the monthly mean relative humidity should not be higher than 90%, and the monthly mean vapor pressure should not exceed 1.8kPa.
2.3 Altitude: Not exceed 1,000m.
2.4 The ambient air should be free from the dust, smoke, corrosive and flammable gas, steam, salt fog, et…
Main specifications and technical parameters
Rated voltage: 33KV 36kv
Power frequency withstand voltage: 95 kv
Lighting impulse withstand voltage: 185 kv
Rated current: 1250A, 1600A, 2000A
Rated short-time withstand current: 25KA, 31.5KA
Rated peak value withstand current: 63KA, 80KA
Rated short-circuit duration: 4 s
Rated short-circuit breaking current: 25KA, 31.5KA
Rated short-circuit making current: 63KA, 80KA
Rated operation sequence: O-0.3s-CO-180s-CO
Breaking time:
1115 Electric Circuit Breakers Suppliers
Short on time? Let Electric Circuit Breakers sellers contact you.