12W
Wall Type
Input voltage/frequency: 100-240Vac, 50/60HzOutput voltage range: 5-24VdcOutput current range: 0.3-2AOutput power range: 3-12WDimension: 60*39*26mmSecurity approval: UL,CUL,CE,GS,CB,FCC,CCC
36W
Wall Type
Input voltage/frequency: 100-240Vac, 50/60HzOutput voltage range: 5-24VdcOutput current range: 0.5-3AOutput power range: 10-18WDimension: 84*52*31mmSecurity approval: UL,CUL,CE,GS,CB,FCC,CCC
CAS:18880-36-9
Trade name: DPS
Chemical name: N,N-dimethyl-dithiocarbamylpropyl sulfonic acid, sodium salt
Molecular formula C6H12NaO3S3
Assay: 98%
Appearance: White to yellowish powder
Application: It is used as a brightening agent in acid copper baths and can get a Bright and ductile deposit when used together with polyetherand wetting agents.
Product name:ups
Chemical name:3-(amidinothio)-1-propanesulfonic acid
Molecular formula:c4h10n2o3s2
Cas no:21668-81-5
Purity:95%
Appearance:white powder
Applicationïthis product can be used together with polyvinyl alcohol or nonionic surfactant in acidic copper plating can get provide bright copper layer with good ductility. Also can be used in other acidic electroplating solution, such as acidic silver plating and palladium plating.
Zps(3-(benzothiazolyl-2-mercapto)-propylsulfonate sodium salt)
Cas no. 49625-94-7 Molecular weight 311.376
Density N/a Boiling p, N/a
Molecular formula C10h10nnao3s3 Melting p, ,320,�,�c (dec.)
Trade name zps
Chemical name 3-(benzothiazolyl-2-mercapto)-propylsulfonate , sodium salt
Sodium 3-(benzothiazol-2-ylthio)-1-propanesulfonate
Ph:2.0-5.0
Assay 90%
Appearance: yellowish powder
Application: used as top brightener in baths for copper and precious metals at a concentration of 10-50mg/l.
CAS: 27206-35-5
Trade name: SPS(SP)
Chemical name: Bis-(sodium sulfopropyl)-disulfide
Other name: SPS
1-Propanesulfonicacid,3,3dithiobis-,disodium salt
3,3dithiobis-1-propanesulfonicacidisodiumsalt
MF: C6H12Na2O6S4
Mw: 354.4
EINECS: 248-324-3
HS:2930909090
Molecular formula: C6H12O6S4(Na)2
Assay: 90%
Appearance: White or yellowish powder
Application: As a brightening agent for acid copper baths for decorative and functional deposits, it is functionally compatible with most components of typical copper bath formulation such as non-ionic surfactants, polymeric amines and other mercapto compounds.
CAS:96-53-7
Trade name H1
Chemical name 2-mercapto thiazoline
Other name: 2-Thiazoline-2-thiol
2-Thiothiazoline
H4MT
Metabasal
Molecular formula C3H5NS2
Assay 98%
MF: C3H5NS2
Mw: 119.21
MDL Number: MFCD00126013
Mp: 105-106 C
Water Solubility: SOLUBLE IN HOT WATER
HS Code: 29341000
Raw materials: Ethanolamine
MDL Number: MFCD00126013
Appearance White needle crystal
Melting point 105-106
Application It is used as main component of additive for acid copper plating. Good brightness and level result can be obtained.
Storage: keep in cool, dry place
CAS: 126-83-0
Other name: 1-Chloro-2-hydroxy-propane-3-sulfonicacid,sodium salt
Sodium 3-chloro-2-hydroxypropanesulfonate
3-Chloro-2-hydroxypropanesulfonic acid, sodium salt
MF: C3H6O4ClSNa
Mw: 196.6
EINECS: 204-807-0
Molecular Formula : C3H6O4ClSNa
Molecular Weight : 196.6
Assay:98.5%
Appearance:White crystalline powder
Application:The molecular structure contains both strong activity halogen atoms and hydroxyl, and contains of the hydrophilic sulfonic acid salt group, is a synthetic polymer industry important functional monomer, also can be used as organic chemical intermediates, for the preparation of surface active agent, modified starch, drilling fluid drop water loss materials.
CAS:49625-94-7
Trade name ZPS
Chemical name 3-(benzothiazolyl-2-mercapto)-propylsulfonate ,sodium salt
Molecular formula C10H10O3NaNS3
Assay 90%
Appearance: Yellowish powder
Application: used as top brightener in baths for copper and precious metals at a concentration of 10-50mg/L.
Product Description
Rail Laser Versine Alignment Device is used for measuring track level and line to aid track measurement and hand tamping operations. It can measure the Horizontal and the Vertical . It is mainly composed of laser transmitting device,target positioning device and moving positioning target device .
Benefits
1.Quick Installation
The operator can put this device on the track in seconds
2.Saving money in repeat work and accuracy
30m at a time with 99.99% reduction on repeat works and rapid deployment
3. Vernier adjustment knob ensuring accurate readings
The vernier adjustment knob assist the operator to ensure a perfect horizontal position ensuring accurate reading .
4. Stored in a dedicated protective case ,Easy to carry
Specification
Laser measure distance
30m
Lser center spot
10mm 30m distanceare
Point
range
horizontal
30+60mm
vertical
30+60mm
target positioning device and moving positioning target device resolution
2mm
1 Battery capacity (laser transmitter)
Continuous use for 4 hours
The digital three-phase shifter is a portable electrical tester composed of transformer phase shifter, digital phase display, voltage current digital display, output voltage adjustment, coarse adjustment, fine adjustment, and power supply, etc. The digital three-phase shifter combines the transformer phase phase technology with digital measurement techniques, which can be adjusted at any angle in the range of 0 to 360 , which has high precision, reading. Accurate intuitive, the voltage output is adjustable, the digital three-phase shifter structural components use independent fixtures, firm and reliable, full seals, easy to carry in the field and on-site use.
Technical parameter
Input voltage Three-phase four-wire 3 380 (220) V 50Hz
The output voltage Three-phase four-wire 3 (0 380) / (0 220) Triple semi-digital display, accuracy: level 1
Output current Communication 0 20A Triple semi-digital display, accuracy: level 1
Maximum output capacity 3 300VA
Three-phase coarse Ambient temperature
The system is suitable for high-voltage 10KV, 35KV low voltage 400V capacity 5000kVA and the following transformer factory test and voltage 10kV capacity 3150kVA and below the distribution transformer no-load test, load test, variable ratio measurement, DC resistance measurement, power frequency withstand voltage test, sensitive The pressure test is integrated integrally integrated, digitized, reducing mechanical faults and reading errors, improves the accuracy and applicability of the overall test system, making the factory trial easier and faster.
Technical parameter
High pressure 35K, low pressure 400V capacity 5000kVA or less dry press factory test High pressure 10K, low pressure 400V capacity 5000kva dryer factory test High pressure 10K, low voltage 400V capacity 3150kVA or less oil immersion press factory test
Voltage transformer metering range and accuracy Voltage Transformer Range: 100V 3.6kV
Voltage transformer gear: 3.6kV, 2kV, 1.2kV, 0.6kV
Current transformer accuracy: 0.05%
Power frequency withstand voltage test Leak current: 300mA
Output voltage: 100kV
Function:
The system has two operating modes (two ways to lock each other, can only work in an operation) automation, flexible design, high integration, complete function
Transformer calibrator is a new automatic instrument. We apply advanced electronic technology in the design. By directly decomposing the error signal, it is able to display the percentage, phase error and orthogonal error statistically. It s quick and energy saving. And it s especially good for live testing due to its cute dimension and light weight.
The current booster is used on checking current transformer,to be the power source supply once current for current transformer or to be other 50Hz single phase current source device.
Technical index
Temperature
Humidit
Capacity: 20kVA
Specification
Weight: 75Kg
Allow long-term work on the rated current
Allowable overload 1.5 times,30 minutes of continuous work.
Feature
This PSLLQ is make up of input Winding(220V), output winding below 100A and CXRZ.
Output current indicated on the nameplate is defined the rated current that through winding allow to pass.When CX many circles, the rated current its permitted to pass through will inversely decline.
The value which ouput capcity divided by product of output current and each circle voltage was the biggest circle number allowing.
The current booster is designed to provide the primary current power supply for the current transformer when verifying the current transformer or as other 50HZ single-phase power equipment. The current booster for transformer verification is suitable for power departments such as power testing, power measurement, and power maintenance. The current booster is developed and produced according to the industry standard of transformer error testing, and is used as a current transformer to verify the primary current of the current transformer. The output current can be customized according to customer requirements. The lifter is equipped with casters for easy on-site movement.
845 Electronics Communications Suppliers
Short on time? Let Electronics Communications sellers contact you.