Please click here to check who's online and chat with them.

Find Verified Electronics Communications Suppliers, Manufacturers and Wholesalers

Top Supplier Cities : Shenzhen   Guangzhou   Dongguan  
Mar-09-17
Supplier From Wuhan, Hubei, China
Sep-25-23
Supplier From Wuhan, , China
Sep-08-22
 
Product description

Portable Three-phase Standard Meter is a portable reference standard meter used to test three phase meters and single phase meters, it designed to work both in the and in the laboratory.



Technical index

Portable Three-phase Standard Meter

Electrical parameters

Accuracy class

0.05%

Voltage supply


Range

5V-480V

Error

Display range

5.000000V-480.0000V

Harmonic

2nd-63st

Range

1mA-120A

Error
Display range

1.000000mA-120.0000A

Active power
0.05% (0.01A-0.2A)



Reactive power

Apparent power

Active energy
Sep-08-22
 
Product description

The portable Three-phase standard power source is suitable for metering departments, power distribution terminals, power management, reactive power compensation devices and enterprise production.



Technical index

Electrical parameters

Accuracy class

0.05%, 0.1%

Power supply

Single phase AC 85-265 V, frequency 50/60 Hz

AC Voltage output

Range (U1, U2, U3 phase)

57.7V/100V/220V/380V; range switch automatically

(Max 500V)



Electrical parameters - continued

0.01% RG

Accuracy

0.05% RG

Stability
Sep-08-22

Handheld Sf6 Gas Leak Detector

$770 - $15.40K
MOQ: Not Specified
 
Product Introduction:


The handheld SF6 gas leak detector is a stable and sensitive leak detector. We have fully considered the actual needs of the majority of users, and at the same time apply our rich technology and experience to this product, allowing users to enjoy an excellent price-performance ratio.



The high-tech central microprocessor unit is the core of the qualitative leak detector for sulfur hexafluoride gas. Its digital signal processing capabilities can better manage circuits and process detection signals. Due to the use of a large number of integrated circuits, the number of components in the circuit is reduced by 40%, which greatly improves reliability and efficiency. The microprocessor can monitor the probe and battery voltage at a rate of 4000 times per second. Even the smallest signal can be captured. It can work stably and reliably in any environment.



The SF6 gas qualitative leak detector has added some convenient functions. Seven-level sensitivity, the sensitivity is increased by 64 times. The three-color LED gradually indicates the degree of leakage in a large range, and is also used to display the sensitivity level and battery power. Touch the keyboard to perform all operations. The avant-garde slender shape design greatly facilitates the user's use and maintenance. It is very convenient to use the indicator light in the direct range.



Technical parameters:
Power supply 3V DC 2 alkaline batteries
Maximum sensitivity R12 R22 R134a approved (14g/year)
Limiting sensitivity about 20 hours
Probe life About 20 hours
Operating temperature
Battery life about 30 hours under normal use
Working way continuous unlimited
Response time instantaneous
Reset time 1 SEC
Warm-up time about 2 seconds
Weight 560g
845 Electronics Communications Suppliers
Short on time? Let Electronics Communications sellers contact you.
Sep-01-22
 
Product description

Portable Three-phase Standard Meter is a portable reference standard meter used to test three phase meters and single phase meters, it designed to work both in the eld and in the laboratory.



Technical index

Portable Three-phase Standard Meter

Electrical parameters

Accuracy class

0.05%

Voltage supply

Range

5V-480V

Error

Display range

5.000000V-480.0000V

Harmonic

2nd-63st

Range

1mA-120A

Error


Display range

1.000000mA-120.0000A

Active power
Sep-01-22
 
Product description

Electrical equipments in modern industrial, commercial and residential users are more sensitive to power quality, and have a higher requirement of quality of power supply. Currently, harmonics,electromagnetic interference, power factor reduction have been tied to the three hazard of the power system.

When it is interfered or contaminated, grid power quality can t reach the national standards, so it has to be targeted on the grid power quality improvement. To understand the actual situation of power quality, you must have the appropriate equipment to test and analysis the actual situation. Counter the domestic condition, our company developed the professional power quality analysis instrument, which is suitable for the country.



3 phase handheld power quality analyzer Technical index

1. Input characteristics
Aug-10-22

Impulse Voltage Generator

$770 - $15.40K
MOQ: Not Specified
 
Product description

The impulse voltage generator intelligent measurement and control system is the latest programmable control system and consists of two parts:

Automatic control of pulse voltage generator program and automatic analysis of pulse signal measurement.



The General Conditions of Use

Altitude: 1000m

Ambient temperature: -5 40 Relative humidity: 90 20 Use of the environment: indoor

Non-conductive dust Grounding resistance 0.5 No fire or explosion hazard

Earthquake resistance: 8 magnitude There is no gas that corrodes metal and insulates

Impulse voltage generator (2)


Supply voltage waveform is the actual sine wave, waveform distortion rate 85% (more than 90% when no load 300PF);

(2)Truncated wave: cut-off time (2-6) 10% s, zero-crossing coefficient 0.3%

(3)Standard operating impulse voltage wave 250 20% s / 2500 60% s,

The impulse voltage waveform parameters and their deviations are in line with the requirements of the national GB311 and GB16927 standards.

7, the lowest output voltage is greater than 10% of the nominal voltage

8. Duration of use: Above 70% of rated voltage, it can be continuously operated every 120 seconds after charging and discharging. It can be continuously operated after charging and discharging every 60 seconds under 70% of rated voltage.

One computer is used for control and waveform analysis 18-inch LCD monitor, strong anti-interference and long life

WINDOWS XP, OFFICE 2003, LabVIEW related driver software, ACE measurement and control software package,built in
Aug-05-22

Oil Immersed Testing Transformer

$770 - $15.40K
MOQ: Not Specified
 
Product description

The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage

Oil Immersed Testing Transformer 1

Technical index

Model

Capacity


High Frequency Voltage Output Voltage
High Frequency Voltage Output Current )

Low Frequency Voltage input

Change

Tempera- ture raised

30 minute

V

A

1.5

50

30

200

7.5

500

10
3

50

60

200

15

500

10

5

50

100

200

25

500

10

10

50

200

220/380

50/26

500

10
Aug-05-22
 
Products Introduction

Ultra-low frequency dielectric strength testing is another method of power frequency withstand voltage testing, because large-capacity testing is required, and large-scale equipment is not only expensive, but also bulky. The power department did some tests to solve these problems. According to domestic and foreign tests, this product can solve this problem. Not only the size of the instrument is small, but the weight is greatly reduced.



Precautions

When carrying out 35KV cable test, one-phase test is strongly suggested. Voltage is set to 60KV (General Requirements)-78KV (according to the rules needed) and the frequency is set to 0.1Hz, 0.05Hz,0.02Hz and 0.01Hz. The manual said load capacity is the theoretical value, the scene 35KV cable length can reach 3-15 km.

In case the cable is too short(less than 500 meters), the capacitance of the test object is smaller than 0.1 F and the pressure cannot be normally boosted, please connect 0.1 F high-voltage capacitance in parallel way.

Keep high-voltage terminals nylon spin by the above numbers to the corresponding nylon seat, high-voltage lines to ensure good contact , no contact is good , it will cause a discharge , burned the high side . When nylon terminals tightened, pay attention to the intensity, excessive tightening may damage the nylon terminals.



80KV 0.1HZ VLF high voltage generator

Model

Rated Voltages

Load capacity

Fuse

Weight

Useful

VLF-80

80kV

(peak )


25A
May-06-22

Voltage Generator

$770 - $15.40K
MOQ: Not Specified
 
Product description

The impulse voltage generator intelligent measurement and control system is the latest programmable control system and consists of two parts:

Automatic control of pulse voltage generator program and automatic analysis of pulse signal measurement.



The General Conditions of Use

Altitude: 1000m

Ambient temperature: 5 40 Relative humidity: 90 20 Use of the environment: indoor

Non-conductive dust Grounding resistance 0.5 No fire or explosion hazard

Earthquake resistance: 8 magnitude There is no gas that corrodes metal and insulates

Impulse voltage generator (2)


Supply voltage waveform is the actual sine wave, waveform distortion rate 85% (more than 90% when no load 300PF);

(2)Truncated wave: cut-off time (2-6) 10% , zero-crossing coefficient 0.3%

(3)Standard operating impulse voltage wave 250 20% s / 2500 60% s,

The impulse voltage waveform parameters and their deviations are in line with the requirements of the national GB311 and GB16927 standards.
Apr-28-22
 
The hand-held network packet analyzer is a hand-held smart substation optical digital network analyzer. It is a new product that relies on the rich on-site debugging experience and user and has been re-designed. It is a substation and the daily maintenance, detection, commissioning, monitoring and analysis equipment of manufacturers. With a new test method, a complete feature gives you a new experience of intelligent substation efficient and convenient testing.



Technical parameter

Voltage current output accuracy Voltage current measurement accuracy The AC current is in the range of 0A-10A, error: no more than 0.01A;
The AC current is in the range of 10A-100kA, error: no more than 0.03%.
Current resolution: current is 0.001A in the range of 0A-100KA
The AC voltage is in the range of 0V- 100V, error: no more than 0.01V;
The AC voltage is within 100V-1000kV range, error: no more than 0.03%.
Current resolution: current is 0.001V in the range of 0V-1000kV
Phase output accuracy Phase measurement accuracy The voltage current phase is in the range of 0-359 , the error is not more than 0.001 , the resolution is 0.01
Packet output synchronization Tester Different optical network ports packet output disabled time no more than 1s
UCA consistency test Test through UCA IEC61850, and obtain the test certificate
Apr-28-22

Three-Phase Phase Volt-Ampere Meter

$770 - $15.40K
MOQ: Not Specified
 
Overview
Three-phase phase volt-ampere meter a high precision instrument for measurement of three-phase electric parameters, it can be used to measure the three phase voltage, current and phase angle, frequency, power, power factor and so on.

three-phase digital volt-ampere phase meter adopt high-speed Cortex M3 processor and 24 bits high-speed ADC a for measuring and calculation , A complete graphical interface, true color display with resolution of 320 x 240 and touch screen operation make a friendly man-machine interface. It is easy to carry
Apr-28-22

Voltage Generator 30Kv

$770 - $15.40K
MOQ: Not Specified
 
Products Introduction

Very Low Frequency high voltage generator 30KV combines advanced technologies such as modern digital conversion, full computer control, automatic voltage increase, voltage reduction, measurement and protection. In the automatic upgrade process, human intervention can be taken care of. The main advantages include full electronics, small size, light weight, large-screen LCD display (clear and intuitive), printer output test report, and easy use.



Technical Parameter
Apr-28-22

Oil Immersed Testing Transformer

$770 - $15.40K
MOQ: Not Specified
 
Product description

The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage

Oil Immersed Testing Transformer 1

Technical index

Model

Capacity



High Frequency Voltage Output Voltage

High Frequency Voltage Output Currentm)

Low Frequency Voltage input

Change

Tempera- ture raised

30 minute

V

A

YD G1.5

1.5

50

30

200

7.5

500

10

YD G 3

3

50

60

200

15

500

10

YD G 5

5

50

100

200

25

500

10

YD G10

10

50

200

220/380

50/26

500

10

YD G 20

20

50

400

380

53

500

10

YD G 30

30

50

600

380

79

500

10

YD G 40

40

50

800

380

105

500

10

YD G 50

50

50

1000

380

132

500

10
Apr-28-22

Impulse Voltage Generator

$770 - $15.40K
MOQ: Not Specified
 
Product description

The impulse voltage generator intelligent measurement and control system is the latest programmable control system and consists of two parts:

Automatic control of pulse voltage generator program and automatic analysis of pulse signal measurement.



The General Conditions of Use

Altitude: 1000m

Ambient temperature: -5 40 Relative humidity: 90 20 Use of the environment: indoor

Non-conductive dust Grounding resistance 0.5 No fire or explosion hazard

Earthquake resistance: 8 magnitude There is no gas that corrodes metal and insulates

Impulse voltage generator (2)


Supply voltage waveform is the actual sine wave, waveform distortion rate 85% (more than 90% when no load 300PF);

(2)Truncated wave: cut-off time (2-6) 10% , zero-crossing coefficient 0.3%

(3)Standard operating impulse voltage wave 250 20% s
2500 60% s,
Jan-20-22

High Voltage Generator 60Kv

$770 - $15.40K
MOQ: Not Specified
 
Products Introduction

VLF high voltage generator 60KV.The capacity of it is 1/500 of tradition way. Greatly simplify testing procedures, That is why commonly used in the developed , s ministry of electric power entrust Wuhan high voltage research institute to drafting 35Kv and below XLPE insulated power cable ultra-low frequency (0.1Hz) voltage withstand test methods for promoting this approach. The instrument is developed according to made of this need. It can be widely used in cable, large-scale high-pressure rotary motor, power capacitors into AC voltage withstand test.



Power capacitance of single-core XLPE insulated cable (F/km)

0.1Hz -60KV Ultra-Low Frequency High Voltage Generator

Model

Rated Voltages

Load capacity

Fuse

Weight

Useful

VLF-60

60kV

(peak )

0.1Hz,0.5F

25A

Control 6

HV TANK-30

HV TANK-II33

25KV and below the cable
Dec-27-21

Handheld Sf6 Gas Leak Detector

$770 - $15.40K
MOQ: Not Specified
 
Product Introduction:


The handheld SF6 gas leak detector is a stable and sensitive leak detector. We have fully considered the actual needs of the majority of users, and at the same time apply our rich technology and experience to this product, allowing users to enjoy an excellent price-performance ratio.



The high-tech central microprocessor unit is the core of the qualitative leak detector for sulfur hexafluoride gas. Its digital signal processing capabilities can better manage circuits and process detection signals. Due to the use of a large number of integrated circuits, the number of components in the circuit is reduced by 40%, which greatly improves reliability and efficiency. The microprocessor can monitor the probe and battery voltage at a rate of 4000 times per second. Even the smallest signal can be captured. It can work stably and reliably in any environment.



The SF6 gas qualitative leak detector has added some convenient functions. Seven-level sensitivity, the sensitivity is increased by 64 times. The three-color LED gradually indicates the degree of leakage in a large range, and is also used to display the sensitivity level and battery power. Touch the keyboard to perform all operations. The avant-garde slender shape design greatly facilitates the user's use and maintenance. It is very convenient to use the indicator light in the direct range.



Technical parameters:
Power supply 3V DC 2 alkaline batteries
Maximum sensitivity R12 R22 R134a approved (14g/year)
Limiting sensitivity about 20 hours
Probe life About 20 hours
Operating temperature 0â??-52â??
Battery life about 30 hours under normal use
Working way continuous unlimited
Response time instantaneous
Reset time 1 SEC
Warm-up time about 2 seconds
Weight 560g
Size 229 65 65mm3
Probe length 35.5cm
Dec-17-21
 
Overview

The hand held network packet analyzer is a hand-held smart substation optical digital network analyzer. It is a new product that relies on the rich on-site debugging experience and user communication in and has been re-designed. It is a substation and the daily maintenance, detection, commissioning, monitoring and analysis equipment of manufacturers. With a new test method, a complete feature gives you a new experience of intelligent substation efficient and convenient testing.



Technical parameter

Voltage current output accuracy Voltage current measurement accuracy The AC current is in the range of 0A10A, error no more than 0.01A;
The AC current is in the range of 10A-100kA, error: no more than 0.03
Current resolution current is 0.001A in the range of 0A-100KA
The AC voltage is in the range of 0V- 100V, error: no more than 0.01V
The AC voltage is within 100V-1000kV range, error no more than 0.03
Current resolution: current is 0.001V in the range of 0V1000kV
Phase output accuracy Phase measurement accuracy The voltage current phase is in the range of 0 359 , the error is not more than 0.001 , the resolution is 0.01
Packet output synchronization Tester Different optical network ports packet output disabled time no more than 1s
UCA consistency test Test through UCA IEC61850, and obtain the test certificate
GOOSE input and output function
The tester is really ready for the Goose output function, supports the output of 60 GOOSE control blocks, and the output message is required to meet the needs of the configuration file. The output message data type can support single point, double point, floating point type

The tester has a Goose reception function, and the analysis of multiple Goose block messages can be performed. The statistics include channel variations, and displacement channel information.
Dec-16-21
 
Overview

Cable check and cable, cable lookups are a bit a bit of arbitrary wiring no need to publicly line. It can greatly improve the construction progress, which is a new test tool in on site construction such as electricity, telecommunications, automation control.

The cable calibration equipment is based on the characteristics of foreign new types of wire tools, combined with the actual situation of China, using digital identification technology, making the test work simple and accurate.



Technical parameter

Parameter Display the maximum row of LEDs 1000, the maximum distance of the quilt is 40km 1.5mmmmmmmmma
size Transmitter Size 135 70 24MM Receiver Size 135 70 24mm


Function

The entire instrument consists of a transmitter and a receiver;

There is no need to determine the public line to make it easy to use

Wire recognition, distribution, application to a part of the wire or multi-heeled wire

One item can be identified, if you need to distinguish more wires can measure or use multiple instruments

Can determine whether there is a short circuit or disconnect between the wires
The receiver is also a disconnect detector that can be used to measure whether the wire is turned on

The structure is small and easy to operate.
845 Electronics Communications Suppliers
Short on time? Let Electronics Communications sellers contact you.
See what buyers and suppliers are discussing in Electronics Communications import export community