Current transformer volt-ampere characteristic tester Only need to set the test voltage, current and step, the device will boost and trace voltage current characteristic test curve automatically, save the cumbersome labor of manual pressure regulation, artificial record, tracing curves, and so. Quick, simple and convenient.

I can not only test CT/PT DC resistance, volt-ampere characteristics, ratio and polarity, 10% error curve, angle difference and ratio difference, but also test secondary load of transformer, CT current test and PT AC withstand voltage test.

CT ratio not only supports traditional current method but also voltage method, so it can meet the test of CT in casing CT and GIS.

Volt-ampere characteristic test single machine output voltage 0-2500V, current 0-20A, can meet most of the transformer volt-ampere characteristic test.

220V single power input and avoids the risk of using 380V.

Current transformer volt-ampere characteristic tester



Main Technical Parameters:

Booster output current & voltage

1A/2500V



2A/1500V



5A/600V



10A/220V



20A/30V

Current generator output current

600A

Output power

3000VA

Voltage and current measurement accuracy



CT ratio tests

Range

1 -40000

Voltage method / current method

Accuracy




PT ratio tests

Range

1 - 40000

Accuracy
Apr-15-15
Supplier From Wuhan, Hubei, China
Dec-28-15
Supplier From Wuhan, Hubei, China
469 Electric Components Suppliers
Short on time? Let Electric Components sellers contact you.
Nov-07-17
Supplier From Wuhan, Hubei, China
Mar-27-17
Supplier From Wuhan, Hubei, China
Dec-24-16
Supplier From Wuhan, Wuhan Tianbang, China
Jul-30-09
Supplier From Wuhan, Hubei Province, China
Aug-19-11
Supplier From Wuhan, Hubei, China
Apr-07-11
Supplier From Wuhan, China
Dec-24-21
 
Product description

The Transformer short circuit impedance tester comes with an adjustable power output. Regardless of single phase or three phase transformers, only one connection is required, and the instrument can complete the measurement of all winding pairs. The test and connection are simple.



Main technical indicators and conditions of use

Measurement accuracy voltage, current 0.2 level

Power COS 0.1 0.5 grade, COS 0.1 1.0 grade

Impedance COS 0.1 0.5 grade COS 0.1: 1.0 grade

Voltage measurement range AC 3V 300V

Internal power output range voltage 0 250V, current 0 10A

Current measurement range AC 0.2A 20A

Working temperature 10 50

Working humidity 0 80

Working power supply AC220V 10 50Hz 1Hz

Dimensions 360mm 220mm 150mm

Weight of the instrument 20Kg

Transformer Short circuit Impedance Tester
Dec-15-21
 
Product description

Single phase standard power supply is suitable for power department, quality control department, research units, institution of higher learning, electric energy meter, power supply management, load control, power quality, reactive power compensation device and production of the enterprise and so on. It can be as single phase voltage source, current source and power source.



Electrical parameters

Electrical parameters

Accuracy class

0.05, 0.1

Power supply

Single phase AC 85-265V, 50 60 Hz

AC Voltage output

Range

57.7V 100 V 220V 380V, Switch automatically max 500V

Adjustment resolution

0.01, 0.1, 1, 10



AC Voltage output

Range 57.7V 100 V 220V 380V, Switch automatically max

Adjustment resolution 0.01, 0.1 1, 10,

Accuracy 0.05 RG

Stability Better than 0.01 RG 1min

Distortion degree Better than 0.1 not capacitive load

Load capacity 40VA

Full load regulation rate Less than 0.01 RG

Full load regulation time Less than 1ms

Temperature drift 8 PPM C

Long-term stability 60 PPM year
Dec-11-13
Supplier From Wuhan, Hubei, China
Dec-15-21
 
Overview

Frequency conversion series resonance test device is designed and manufactured for alternating-current withstand voltage test of Possessing a wider application scope, it is the ideal withstand voltage equipment for prefecture-level, municipal-level and county-level high-voltage test departements as well as power installation and repair & testing engineering units.

Frequency Conversion Series Resonance Test Device

Technical index

Rated voltage

Quality factor under full load in test of fire power generator Q 10 relating to load

Quality factor under full load in cable test Q 30 relating to load
Quality factor under full load in test of main transformer: Q 30 relating to load

GIS, the quality factor under full load in switch test and other tests Q 50 relating to load

Input power supply single phase of 380V

Frequency adjustment range 20Hz 300Hz

Accuracy of system measurement 1.5

The unit possesses protective functions, such as over voltage, over current and zero start.



Description for main configuration and technical data of equipment

One set of variable-frequency power supply

Rated power 10kVA;

Input voltage single phrase of 220V or three phase of 380V 10 and 45 65Hz

Output voltage 0 400V adjustable

Output voltage frequency 30 300Hz

0.1Hz adjustable stepping

Instability degree of frequency 0.02

Output current: 0 25A
Jun-03-18
Supplier From Wuhan, Hubei, China
May-06-22
 
Product description

Insulation resistance tester with absorption ratio embedded real-time industrial microcomputer operating system, ultra-thin wire-shaped sheets header with the perfect combination of dot matrix liquid crystal display, the instrument is with a variety of voltage output level (250V,500V,1000V,2500V,5000V,10000V), high capacity, strong anti-interference, the pointer and digital synchronous display, AC-DC dual-use, simple operation, automatic calculation of various insulation index (absorption ratio, polarization index), all measured characteristics with the anti-power-down function .



Technical index

Measuring range and accuracy

(Temperature, humidity: 235, 45 75%RH)

Model

BC2305

Rated

Voltage

250V

500V

1000V

2500V

5000V

Measuring Range

0.099.9M
Dec-18-20
Supplier From Wuhan, Hubei, China
Aug-10-22
 
Overview

The transformer integrated test system complies with GB1094, GB / T4776, GB / T5169 and other relevant national standards. With the increase in transmission and electrical power generation and the continuous increase in power grids, the successful transformation of the national city network, the farnet, and the number of online quantities and capacity of power transformers are increasing.





Technical parameter:

Equipment measurement range and precision Voltage metering range: 50V 500V
Voltage metering accuracy: 0.2%
Current metering range: 0.1a 5a (can be 0.1A 1A)
Current metering accuracy: 0.2%;
Power frequency withstand voltage test Leak current: 400mA
Input current monitoring instrument Monitoring range: 200A




Function:

Equipment failure automatic detection function, automatically detect peripherals, such as: the voltage regulator is zero, etc .;

Test item: no-load loss measurement, no-load current percentage (automatic conversion to the value of the rated voltage), load loss measurement, the impedance voltage percentage (automatic conversion to the rated current reference temperature) Automatic measurement (voltage ratio measurement, connection group label test), external pressure test (power frequency withstand voltage test), induction pressure test (multiplier multiplier test), insulation resistance measurement, lightning shock test, insulation Oil test (breakdown voltage, flash point, acid value, volume resistivity, moisture, etc.), local discharge test, temperature rise test
Sep-11-20
Supplier From Wuhan, Hubei, China
469 Electric Components Suppliers
Short on time? Let Electric Components sellers contact you.
See what buyers and suppliers are discussing in Electric Components import export community