Overview
Three-phase phase volt-ampere meter a high precision instrument for measurement of three-phase electric parameters, it can be used to measure the three phase voltage, current and phase angle, frequency, power, power factor and so on.
three-phase digital volt-ampere phase meter adopt high-speed Cortex M3 processor and 24 bits high-speed ADC a for measuring and calculation , A complete graphical interface, true color display with resolution of 320 x 240 and touch screen operation make a friendly man-machine interface. It is easy to carry
Very Low Frequency high voltage generator 30KV combines advanced technologies such as modern digital conversion, full computer control, automatic voltage increase, voltage reduction, measurement and protection. In the automatic upgrade process, human intervention can be taken care of. The main advantages include full electronics, small size, light weight, large-screen LCD display (clear and intuitive), printer output test report, and easy use.
VLF high voltage generator 60KV.The capacity of it is 1/500 of tradition way. Greatly simplify testing procedures, That is why commonly used in the developed , s ministry of electric power entrust Wuhan high voltage research institute to drafting 35Kv and below XLPE insulated power cable ultra-low frequency (0.1Hz) voltage withstand test methods for promoting this approach. The instrument is developed according to made of this need. It can be widely used in cable, large-scale high-pressure rotary motor, power capacitors into AC voltage withstand test.
Power capacitance of single-core XLPE insulated cable (F/km)
0.1Hz -60KV Ultra-Low Frequency High Voltage Generator
Light digital relay protection tester characteristics 4 6 8 pairs of 100M Optical Fiber Communication Ethernet interface, can send and receive the sampling value of the IEC61850 9 1 2 frame format, Goose, IEEE 1588 packets more support 24 sets of SV packets 64 groups of Goose packets simultaneously 3 5 pairs of 2 10M fiber serial port, can send and receive IEC60044 7 8 FT3, national network expansion FT3, Xu Ji privately owned FT3 frame format sampling value 12 road simulation small signal output, provides testing of protection devices input for small signals
Overview
Three phase phase volt-ampere meter a high precision instrument for measurement of three phase electric parameters, it can be used to measure the three phase voltage, current and phase angle, frequency, power, power factor and so on.
three phase digital volt-ampere phase meter adopt high-speed Cortex M3 processor and 24 bits high-speed ADC a for measuring and calculation , A complete graphical interface, true color display with resolution of 320 240 and touch screen operation make a friendly man-machine interface. It is easy to carry
Three Phase Energy Meter Field Calibrator is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure various of AC parameters.
Technical index
Electrical parameters
Accuracy class
0.05, 0.1
Resolution
6 TFT 640 480
Electrical parameters - continued
Power supply
220V 10%, 50 60Hz
Li-polymer battery size mm 110 51 16, nominal output voltage 7.2V, capacity 5000mAh
Products Introduction
The power department did some tests to solve some problems. According to theories and test results at home and abroad, the 50KV Very Low Frequency high voltage generator withstand voltage test can solve this problem. Its advantages are that not only the test results are the same, but the instrument size is small and the weight is greatly reduced.
output rated voltage power fuse Refer to the following table
Transformer load box is also called current transformer load box, voltage transformer load box, PT load box and CT load box. Current, voltage transformer load box and transformer load box. When testing current and voltage transformers, PT/CT mutual inductance The load box provides a variety of effective loads and is an ideal accessory product for various transformer verification devices.
VLF high voltage generator 60KV.The capacity of it is 1/500 of traditional way. Greatly simplify testing procedures, That is why commonly used in the developed countries, china ministry of electric power entrust Wuhan high voltage research institute to drafting 35Kv and below XLPE insulated power cable ultra-low frequency (0.1Hz) voltage withstand test methods for promoting this approach. The instrument is developed according to China's made of this need. It can be widely used in cable, large-scale high-pressure rotary motor, power capacitors into AC voltage withstand test.
Power capacitance of single-core XLPE insulated cable (µF/km)
0.1Hz -60KV Ultra-Low Frequency High Voltage Generator
Model
Rated Voltages
Load capacity
Fuse
Weight
Useful
VLF-60
60kV
(peak )
0.1Hz, 0.5 µF
25A
Control 6
HV TANK-I30
HV TANK-II 33
25KV and below the cable Generator
0.05Hz, 1.0 µF
0.02Hz, 2.5 µF
0.01Hz, 5.0 µF
Precautions
1.Please use the STOP button and discharge by rod then shut down the power if you need to discontinue the machines which in the high pressure conditions.Otherwise it will damage the instrument!
2.Please operation it according to the screen instructions.
3.It is a normal phenomenon to see small amount of oil spill after boosting the pressure because the insulating oil in the booster is full, besides, it will not affect your use.
4.When carrying out 10KV cable test, one-phase test is strongly suggested. The voltage shall be 18KV and the frequency shall be 0.1Hz 0.05Hz 0.02Hz 0.01Hz. The manual said load capacity is the theoretical value, the scene 10KV cable length can reach 3-20km.
AC and DC dual purpose AC and DC withstand voltage tester. The winding is theconcentric pagoda and multilayer cylindrical type low-voltagewinding in inner high-voltage winding in outside; Outer cover is portable which has characteristics such as volume smallness weight light the shape prettiness and move convenience and so on.
xc control cabinet Technical Paramenters:
environment temperature 0-40
altitude < 100m
relative humidity < 85%
Main product specifications
type specification capacity power source output operating mode Refer to the weight
anthroposcopy (V) (A) (V) (A)
XC-2 2 1 220 50 0-220 10 manual operation 14
XC-3 3 1 220 50 0-220 15 manual operation 16
XC-5 5 1 220 50 0-220 20 manual operation 18
40KV vlf high voltage generator of this product fully complies with the standards of the electric power industry. Mechanical methods are widely used to modulate and demodulate ultra-low frequency signals, but there is no standard sine wave, some errors in high-voltage part measurement and spark discharge. The product can overcome the above shortcomings.
How to choose the suitable products for test
Please make sure that the capacitance of test products is below the instrument rated capacitance. The waveform will be influence if the capacitance of test products is too small and the instrument can not normally output when it below 0.05µF. 0.05µF capacitor in parallel to auxiliary output. Below is capacitance of some instrument for your reference.
40KV vlf high voltage generator parameter :
Model
Rated Voltages
Load capacity
Fuse
Weight
Useful
VLF-40
40kV
(peak )
0.1Hz,1.1µF
20A
Control 6
Body Boost 50
Used for cable and generator with corresponding voltage
The Portable single-phase electric meter Test Equipment is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high precision standard power source, ac voltage source and current source.
Single-phase electric meter field calibrator is suitable to test various types single phase meters on site and can also be used to test alternating current parameters.
Feature
1. Current clamp and meter combined together, colorful and touch-screen display;
2. One AAA Li-battery can continuously working 4 hours;
3. Wide voltage, current measurement range, voltage range: 15-300V, current range: 0.05-120A;
4. Display all the measuring parameters in one screen;
5. Current clamp has automatic compensation function, 0.2% class accuracy;
6. Current clamp has automatic calibration function;
7. Integration design of the meter and clamp;
8. 16bit high accuracy AD switch 32 bit ARM processor core.
9. Automatically record and save 999 groups calibrate data;
10. Micro-multifunction optic sampler
Technical index
1. Manual/automatic test inductive single phase meters;
2. Manual/automatic test electric single phase meters;
3. Measure virtual value of alternating voltage (15~300Vrms);
4. Measure virtual value of alternating current (50mA~120Arms);
5. Test parameters: active power, phase angle of voltage and current, frequency and etc;
6. Automatic store testing data, and 999 group test results can be saved.
Three Phase Energy Meter Field Calibrator is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure various of AC parameters.
Product description
Three-phase electric energy meter calibrator is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single/three-phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high-precision standard power source.
Technical index
Electrical parameters
Accuracy
0.05%, 0.1%
Power Supply
One Phase AC 180-265V, frequency 50/60Hz.
AC Voltage Output
Range(U1,U2,U3)
57.7V, 100V, 220V, 380V
or 69.3V, 120V, 240V, 480V( optional)
Adjustment range
(0-120)%RG(1)
Adjustment �neness
0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Very Low-Frequency high voltage generator 30KV combines advanced technologies such as modern digital conversion, full computer control, automatic voltage increase, voltage reduction, measurement and protection. In the automatic upgrade process, human intervention can be taken care of. The main advantages include full electronics, small size, light weight, large-screen LCD display (clear and intuitive), printer output test report, and easy use.
Technical Parameter
1 output frequency 0.1Hz 0.05Hz 0.02Hz 0.01Hz
2 Loading capability : Table 1 for reference
0.1 Hz maximum 1.1F
0.05 Hz maximum 2.2F
0.02 Hz maximum 5.5F
0.01 Hz maximum 11.0F
3 accuracy :± (3% of full scale +0.5 KV)
4 voltage waveform distortion 5%
5 condition of use : indoor, outdoor; temperature : -10+40humidity 85%RH
6 power supply AC50 Hz 220V +5%
7 power fuse : output rated voltage Table for reference