Please click here to check who's online and chat with them.

Find Verified Electronic Transformers Suppliers, Manufacturers and Wholesalers

Top Supplier Cities : Shenzhen   Guangzhou   Dongguan  
Dec-10-21

Transformers

$770 - $15.40K
MOQ: Not Specified
 
Product Introduction
Capacitive voltage transformer (CVT) in calibration the test must be conducted under the condition of 50Hz frequency complex geographical condition on site at the same time the traditional experiment device is difficult to meet the requirements of on-site handling testing series resonance booster device is first used in domestic field tunable resonance device has been widely used in domestic 500 kv and below the field calibration of capacitor voltage transformer.



Product Parameters
Technical parameters
Rated Capacity 80kVA
rated voltage 160kV
Adjustable inductance range 65~130H
Rated frequency 50Hz
Rated current 0.5A
Adjustable gap range 0~300mm
Dec-03-21

Current Transformer

$770 - $15.40K
MOQ: Not Specified
 
Product description

Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard



technical parameter

Temperature -5 40

Relative humidity 80%

Rated Primary Current 5-5000A 5A,1A

Rated secondary current 5A 1A

Accuracy Class 0.05S
Allow long-term work under the rated current; More than120A across the core.



Precautions

The current of standard CT and tested CT must be the same in CT calibration.

Follow the given wiring diagram strictly.

Test whether the load box is accurate or not before calibrating the transformer.

Forbid secondary winding opening during the calibration.

Select demagnetization before calibration.The wiring diagram is shown in figure 5.

Short out the secondary winding before cutting off the power when the demagnetization is finished.

Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Feb-03-09
Supplier From Shangyu, Zhejiang, China
Mar-02-09
Supplier From Dongying, Shandong, China
Feb-22-10
Supplier From Wuxi, Jiangsu Province, China
226 Electronic Transformers Suppliers
Short on time? Let Electronic Transformers sellers contact you.
Apr-14-10
Supplier From Zhongshan, Guangdong, China
Apr-16-10
Supplier From Dong Gguan, Guangdong Province, China
Jan-12-12
Supplier From Guangzhou, Guangdong, China
May-26-12
Supplier From Jiangyin, Jiangsu, China
Sep-27-11
Supplier From Changzhou, Jiangsu Province, China
Sep-25-13
Jul-17-15
Supplier From Xiamen, Fujian Province, China
Sep-14-15
Oct-12-22
Supplier From Pinghu, China
Aug-05-16
Supplier From Donggaun, Guangdong, China
Aug-30-17
Supplier From Hefei, Anhui, China
Mar-08-24
Dec-21-23
Supplier From Xuzhou, Jiangsu, China
Feb-05-18
226 Electronic Transformers Suppliers
Short on time? Let Electronic Transformers sellers contact you.