Please click here to check who's online and chat with them.

Find Verified X Ray Parts Instruments Suppliers, Manufacturers and Wholesalers

Sep-30-19

Medical Dr X-Ray Upgrade Kit

$13.00K
MOQ: Not Specified
Supplier From Seoul, South Korea (Republic Of Korea)
 
- Wired / 17"x17" / CsI / US FDA / CE
- Console software included
Sep-20-19
 
TUNNEL SIZE: 530(w)*350(H)mm CONVEYOR SPEED: 0.22m/s
TYPE: Mutil Energy CONVEYOR: 200 Kg
STEEL PENETRATION: 38mm WIRE RESOLUTION: 40AWG
WARRANTY: 2 Years PRODUCT NAME: X-ray Baggage Scanner
High Resolution 32mm Penetration 5335 Dual Energy X-ray Baggage Scanner



Model: HPC-BF5335

General Specifications

Tunnel Size : 530 (W) Ã?350 (H) mm

Conveyor Speed: 0.22m/s

Conveyor Max Load: 100 kg

Single inspection dosage: < 1.32μGy

Wire Resolution: 40AWG

Steel Penetration: 32mm

Film Safety: For ISO 1600



X-RAY GENERATOR

Orientation: Upward

Tube Current:0.4~0.7mA(adjustable)

Anode Voltage:80KV(adjustable)

Angle: 60°

Generator cooling/working periods:

Sealed oil bath with forced air/100%

OPERATING ENVIRONMENT

Storage Temperature: -20oC to 60oC

Operating Temperature: 0oC to 45oC

Relative Humidity:

20 to 95% non-condensing

System Power: 220 VAC (±10%) 50±3HZ

Power wastage: 1.0 KW (Max)

Noise
Sep-18-19
 
TUNNEL SIZE: 500 (W) *300 (H) Mm CONVEYOR SPEED: 0.22m/s
TYPE: Single Energy CONVEYOR: 100 Kg
STEEL PENETRATION: 10mm WIRE RESOLUTION: 40AWG
WARRANTY: 2 Years PRODUCT NAME: X-ray Baggage Scanner
TIP function Auto operation HPC-B5030 Small size dual energy xray baggage scanner



Metro / hotel / train station / public places



Model:HPC-B5030

General Specifications

Tunnel Size : 500 (W) Ã?300 (H) mm

Conveyor Speed: 0.22m/s

Conveyor Max Load: 100 kg

Single inspection dosage: < 1.32μGy

Wire Resolution: 40AWG

Steel Penetration: 40mm

Film Safety: For ISO 1600



X-RAY GENERATOR

Orientation: Upward

Tube Current:0.4~0.7mA(adjustable)

Anode Voltage:80KV(adjustable)

Angle: 60°

Generator cooling/working periods:

Sealed oil bath with forced air/100%

OPERATING ENVIRONMENT

Storage Temperature: -20oC to 60oC

Operating Temperature: 0oC to 45oC

Relative Humidity:

20 to 95% non-condensing

System Power: 220 VAC (±10%) 50±3HZ

Power wastage: 1.0 KW (Max)

Noise
Sep-13-19
 
Items Parameters
Model : XXG-2005
Max. Penetration A3 Steel : 30mm
Exposure Time : 5 minutes
Film Type : T3
Input Voltage : AC198-240V/50Hz (60Hz)
Capacity : 2.0kVA
Ambient Temperature :-30~40
Ambient Humidity 85%
X-ray Tube material : ceramic
Emission : Directional
Focal Size : 2 2.0mm
Radiation Angle : 40 °
Output Voltage : 100-200kV
Output Current : 5mA
X-ray Generator Cooling : Fan
Insulation : SF6
Pressure Gauge : 0.34MPa0.45MPa
x ray generator Dimension : D285*H615mm
x ray generator Weight : 24Kg
Controller Dimension : 300300140mm
Controller Weight : 8Kg
Sep-13-19
 
Items Parameters
Model : XXQ-3505
Max. Penetration A3 Steel : 60 mm
Exposure Time : 5 minutes
Film Type : T3
Developing Time : 5 minutes
Blackening : 1.5
Sensitivity : 1.8%
Input Voltage : AC198-240V/50Hz (60Hz)
Capacity : 3.5 kVA
Ambient Temperature : -30~40
Ambient Humidity :85%
X-ray Tube material : glass
X-ray Tube Emission : Directional
Focal Size : 2.52.5mm
Radiation Angle : 40 °
Output Voltage : 180-350kV
Output Current : 5mA
X-ray Generator Cooling : Fan
Insulation : SF6
Pressure Gauge : 0.34Mpa 0.45MPa
X-ray Generator Dimension D345*H830 mm
X-ray Generator Weight 48 Kg
Controller Dimension 350290150mm
Controller Weight 10Kg
664 X Ray Parts Instruments Suppliers
Short on time? Let X Ray Parts Instruments sellers contact you.
Sep-13-19
 
Items Parameters
Model :XXGH-3005
Max. Penetration A3 Steel : 47 mm
Focal Length : 600 mm
Exposure Time :5 minutes
Film Type : T3
Operation Temperature in Darkroom : 20
Developing Time :5 minutes
Blackening : 1.5
Sensitivity : 1.8%
Input Voltage :AC198-240V/50Hz (60Hz)
Capacity :3.5 kVA
Ambient Temperature :-30~40
Ambient Humidity : 85%
X-ray Tube material :ceramic
X-ray Tube Emission :Panoramic
Focal Size :1.02.5mm
Radiation Angle : 360 ° * 25°
Output Voltage :170-300kV
Output Current : 5mA
X-ray Generator Cooling : Fan
Insulation : SF6
Pressure Gauge : 0.34MPa0.45MPa
X-ray Generator Dimension : D320*H630 mm
X-ray Generator Weight : 34 Kg
Controller Dimension : 350290150mm
Controller Weight :10Kg
Sep-13-19
 
Items Parameters
Model : XXH-2505
Max. Penetration A3 Steel : 37 mm
Exposure Time : 5 minutes
Film Type : T3
Operation Temperature in Darkroom :20
Developing Time : 5 minutes
Blackening : 1.5
Sensitivity : 1.8%
Input Voltage : AC198-240V/50Hz (60Hz)
Capacity : 2.5 kVA
Ambient Temperature : -30~40
Ambient Humidity : 85%
X-ray Tube material : glass
X-ray Tube Emission : Panoramic
Focal Size : 2.02.0mm
Radiation Angle : 360 °x 30°
Output Voltage : 150-250kV
Output Current : 5mA
x-ray Generator Cooling : Fan
Insulation : SF6
Pressure Gauge : 0.34MPa0.45MPa
X-ray Generator Dimension : D320*H730 mm
X-ray Generator Weight : 35 Kg
Controller Dimension : 350290150mm
Controller Weight : 10Kg
Sep-11-19
 
YG-100A1 X-ray pipeline crawler
No Items Parameter Remarks
1 Operational Pipe DN700-DN1400
2 Max. Penetration 42mm A3 Steel
3 Max. Output Voltage 300Kv 0~5 Steps Shift
4 Max. Output Current 3mA
5 Focus 1.0Ã?2.5mm
Beam Angel 360°Ã?30°
6 Working Temperature ï¼?40°~ 70°
7 Relative Humidity â?¤90%
8 Capacity of Battery 110V, 22Ah Lead acid battery
9 Motor Power 250W Continuous Rare earth motor
10 Exposure Delay 24s Safety time for distance
11 Exposure Duration 1~300sï¼?Continuously variableï¼?Set by Touching LCD
12 Slope Ability Two-wheel driveï¼?â?¤27°
Four-wheel driveï¼?Manual):â?¤40° Optional
13 Positioning error ±5mm
14 Proceeding Distance 5Km Round-trip
15 Proceeding Speed 15m/min~18m/min
16 Turning Radius â?¥7D Curve in pipeline
17 Weight Body 50.5Kg
Total117.5Kg Excluding Generator and batteries
Batteries 67 Kg Power unit of crawler
Generator 34Kg Component generating x-rays
Commander 2.8Kg Positioning device
18 Outline Dimension Crawler 1.2Ã?0.38Ã?0.1 9m
Generator Φ274�765 mm XXH-300�Panoramic Cone�
19 Commander Outlineï¼? 255Ã?113Ã?155 mm Positioning device(12 hours enduranceï¼?
Max. Penetration Thickness: 34mm
Sep-10-19
 
Items Parameters
Model : XXG-2005
Max. Penetration A3 Steel : 30mm
Exposure Time : 5 minutes
Film Type : T3
Input Voltage : AC198-240V/50Hz (60Hz)
Capacity : 2.0kVA
Ambient Temperature :-30~40
Ambient Humidity 85%
X-ray Tube material : ceramic
Emission : Directional
Focal Size : 2 2.0mm
Radiation Angle : 40 º±5°
Output Voltage : 100-200kV (±2%)
Output Current : 5mA (±2%)
X-ray Generator Cooling : Fan
Insulation : SF6
Pressure Gauge : 0.34MPa0.45MPa
x ray generator Dimension : D285*H615mm
x ray generator Weight : 24Kg
Controller Dimension : 300300140mm
Controller Weight : 8Kg
Sep-10-19
 
Items Parameters
Model : XXH-2505
Max. Penetration ï¼?A3 Steelï¼? : 37 mm
Exposure Time : 5 minutes
Film Type : T3
Operation Temperature in Darkroom :20±2
Developing Time : 5 minutes
Blackening : 1.5
Sensitivity : 1.8%
Input Voltage : AC198-240V/50Hz (60Hz)
Capacity : 2.5 kVA
Ambient Temperature : -30~40
Ambient Humidity : 85%
X-ray Tube material : glass
X-ray Tube Emission : Panoramic
Focal Size : 2.02.0mm
Radiation Angle : 360 º x 30°
Output Voltage : 150-250kV (±2%)
Output Current : 5mA (±2%)
X-ray Generator Cooling : Fan
Insulation : SF6
Pressure Gauge : 0.34MPa0.45MPa
X-ray Generator Dimension : D320*H730 mm
X-ray Generator Weight : 35 Kg
Controller Dimension : 350290150mm
Controller Weight : 10Kg
Sep-10-19
 
Items Parameters
Model :XXGH-3005
Max. Penetration ï¼?A3 Steelï¼? : 47 mm
Focal Length : 600 mm
Exposure Time :5 minutes
Film Type : T3
Operation Temperature in Darkroom : 20±2
Developing Time :5 minutes
Blackening : 1.5
Sensitivity : 1.8%
Input Voltage :AC198-240V/50Hz (60Hz)
Capacity :3.5 kVA
Ambient Temperature :-30~40
Ambient Humidity : 85%
X-ray Tube material :ceramic
X-ray Tube Emission :Panoramic
Focal Size :1.02.5mm
Radiation Angle : 360 º*25°
Output Voltage :170-300kV (±2%)
Output Current : 5mA (±2%)
X-ray Generator Cooling : Fan
Insulation : SF6
Pressure Gauge : 0.34MPa0.45MPa
X-ray Generator Dimension : D320*H630 mm
X-ray Generator Weight : 34 Kg
Controller Dimension : 350290150mm
Controller Weight :10Kg
Sep-10-19
 
Items Parameters
Model : XXQ-3505
Max. Penetration A3 Steel : 60 mm
Exposure Time : 5 minutes
Film Type : T3
Developing Time : 5 minutes
Blackening : 1.5
Sensitivity : 1.8%
Input Voltage : AC198-240V/50Hz (60Hz)
Capacity : 3.5 kVA
Ambient Temperature : -30~40
Ambient Humidity :85%
X-ray Tube material : glass
X-ray Tube Emission : Directional
Focal Size : 2.52.5mm
Radiation Angle : 40 º±5°
Output Voltage : 180-350kV (±2%)
Output Current : 5mA (±2%)
X-ray Generator Cooling : Fan
Insulation : SF6
Pressure Gauge : 0.34Mpa 0.45MPa
X-ray Generator Dimension D345*H830 mm
X-ray Generator Weight 48 Kg
Controller Dimension 350290150mm
Controller Weight 10Kg
Apr-26-19

Medical Dr X-Ray System

$12.00K
MOQ: Not Specified
Supplier From Seoul, South Korea (Republic Of Korea)
 
medical DR x-ray system

17x17" / Wired / GOS / US FDA / CE
Apr-26-19

X-Ray Protective Aprons

$120
MOQ: Not Specified
Supplier From Seoul, South Korea (Republic Of Korea)
 
X-ray protective Aprons

- Lead Apron
- Lead-Free Apron
Jan-12-17
 
X ray tube technology parameters
 
Testing equipment using x ray tube
Mainly used for application in the heat, pressure vessel, aviation, aerospace, electric power, petroleum, chemical, pipeline, military industry, nuclear industry, shipbuilding, automobile, metallurgy, steel structure, railway, university, luggage and parcel safe industries such as manufacturing, production, quality control links.
mode Tube voltage Tube current spots Filament voltage ThefilamentcurrentRadiation Angle
(KVp) (mA) (mm) (V) (A)




(°) The length of the
XA33A 160 2 0.8* 0.8 5.3 4.4 40°+5° 68mm190mm
XA33B 160 4 0.3*0 .8 4 3.5±0.2 110°�40° 68mm190mm
XA33C 160 4 2.5*0.8 3.5±0.2 3.7±0.2 110°�20° 68mm190mm
XA33D 160 2 0.8* 0.8 3.5±0.2 3.70±0.2 80°�60° 68mm190mm
XA33E 160 4 0.8*0.8 3.5±0.2 3.7±0.2 60° 68mm190mm
XA33F 160 5 0.8*0.8 3.5±0.2 3.7±0.2 40°�60° 68mm190mm
XA33G 200 3 1.5*1.5 4.6±0.2 3.4±0.2 80°�60° 211mm
XA36H 100 1.4 0.6�0.6 5±0.2 2.1±0.2 40°�60° ���mm
Jan-11-17
 
X-ray digital imaging system (dr - digital radiograph) by imaging, x-ray machine, the x-ray machine synchronous control unit, with the highest detection sensitivity of the high-tech equipment. All digital radiographic testing standard, including welding, casting, corrosion testing standards, including metal, nonmetal and composite materials testing a variety of purposes, such as widely used in aviation, spaceflight, automobile, electric power, petroleum, chemical industry, pharmacy, special inspection, etc. High reliability, long life, low failure rate, high resolution, high resolution detector humanized design software, the interface is simple, easy to operate, according to the test requirements, develop software functions
X-ray real-time imaging cylinder welding seam detection
Scope of application and main technical parameter
1 main application: used in cylinders and all kinds of metal materials internal welding defects, such as blow hole, shrinkage cavity, porosity, crack, weld defects, etc.
2�checked the product size:
Size: 100-800 - mm diameter or less;height 600-2200 - mm or less
3�the x-ray flaw detecti ng closed refrigeration, has forced cooling, the flow protection, temperature protection and self protection tube temperature 40 ?? or less and the capacity to ensure that equipment work continuously.
59 "x-ray real-time imaging system (xsc9b) or varian1313 flat-panel detector.
Jan-05-17
 
X ray tube technology parameters
Testing equipment using x ray tube
Mainly used for application in the heat, pressure vessel, aviation, aerospace, electric power, petroleum, chemical, pipeline, military industry, nuclear industry, shipbuilding, automobile, metallurgy, steel structure, railway, university, luggage and parcel safe industries such as manufacturing, production, quality control links.
specifications Tube Tube Filament The filament spots size
voltage current voltage current
ï¼?KV) ï¼?mA) (V) (A) (mm) (mm)
XA-801 80 1.5 5±0.5 2.1 0.8*0.8 116±1
XA-801A 80 1.5 5±0.5 2.1 0.8*0.8 116±1
XA-1001 100 1.5 5±0.5 2.1 0.8*0.8 116±1
XA-1001A 100 1.5 5±0.5 2.1 0.8*0.8 116±1
XA-1402 140 2.5 5±0.5 4 0.8*0.8 190±2
XA-1402A 140 2.5 5±0.5 4 0.8*0.8 190±2
XA-1602A 160 2.5 5±0.5 4 0.5*0.5 190±2
XA-2003 200 2.5 5±0.2 4 1.5*1.5 211±1
Jan-05-17
 
X ray tube technology parameters
 
Testing equipment using x ray tube
Mainly used for application in the heat, pressure vessel, aviation, aerospace, electric power, petroleum, chemical, pipeline, military industry, nuclear industry, shipbuilding, automobile, metallurgy, steel structure, railway, university, luggage and parcel safe industries such as manufacturing, production, quality control links.
 
mode Tube voltage Tube current spots Filament Thefilame Radiation Angle
voltage ntcurrent
(KVp) (mA) (mm) (V) (A) (°)
XA33A 160 2 0.8* 0.8 5.3 4.4 40°+5°
XA33B 160 4 0.3*0.8 4 3.5±0.2 110°�40°
XA33C 160 4 2.5*0.8 3.5±0.2 3.7±0.2 110°�20°
XA33D 160 2 0.8* 0.8 3.5±0.2 3.70±0.2 80°�60°
XA33E 160 4 0.8*0.8 3.5±0.2 3.7±0.2 60°
XA33F 160 5 0.8*0.8 3.5±0.2 3.7±0.2 40°�60°
XA33G 200 3 1.5*1.5 4.6±0.2 3.4±0.2 80°�60°
XA36H 100 1.4 0.6�0.6 5±0.2 2.1±0.2 40°�60°
May-24-17
 
radiography X-ray Equipment PLX6500 with bucky stand


Features of Digital Chest X Ray Machine PLX6500
1.Close-table graphical color LCD touch screen and wireless
remote control exposure
2.The latest compact high-frequency and high voltage X-ray
generator
3.High frequency high voltage X-ray source and high
frequency inverter power supply
4.Possess multiple automatic protection and fault clue
function

Application of HF radiography X-ray Equipment PLX6500
Multiple function 200mA medical x ray system Used to
photograph patient's head,chest, stomach,lumbar and
extremities
We owned many patents in technique such as ISO, TUV and more
and more machines got CE certifications. In a word, our
company is reliable and invest-worthy.

z
May-24-17
 
ICU patient monitor displaying multi parameter JP2000-07


Application of High Quality Patient Monitor JP2000-07:
For adult,children,inffans,ICU,operation room, emergency
room,each deparrtment;the ambulance,visits, community
hospital.Main monitoring parameters include patient's ECG/
heart rate,respiration,non-invasive blood pressure,oxygen
saturation,pulse rate,body temperature of six parameters.

Features of ICU patient bedside monitor JP2000-07:
1. Size of Screen: 6'TFT Color LCD with resolution of
640*480
2.Waveform display: 4 channel waveform display in screen
with the waveforms of ECG, Respiration, NIBP and SpO2 With
E-manual embedded Can work with portable printer
3. Alarm System: Voice alarming system, Light and sound
alarming
4. Expert Low power cost: 4W. Portable long life Li-ion
battery with smart management of charge and power consume,
can work without AC power longer than 3 hours
5. ECG: 3 channel ST segment analysis. Resist 50Hz AC
disturbance, can work with electrosurgical unit and de-
trembling
6. NIBP: Measure Method: Advanced One-step Method.
7. Can auto identify the measurement of baby child and
adult.
8.Can display the waveform of blood pressure.
9.Can display the result with mmHg/kPa simultaneously in
screen
10. SpO2: Can resist the disturbance of the patient
movement.
11. Can display the chart of previous data of Heart Rate,
VPC, Three Level ST Segment, NIBP, SpO2, Pulse Rate,
Respiration Rate and Temperature in 1-96 hour

z
664 X Ray Parts Instruments Suppliers
Short on time? Let X Ray Parts Instruments sellers contact you.
See what buyers and suppliers are discussing in X Ray Parts Instruments import export community