Ratings
Volts
690 Vac/500 Vdc (IEC)
700 Vac/500 Vdc (UL)
Amps 6-200 A
IR
CT: IEC 90 kA RMS Sym., 40 kA at 500 Vdc,
UL 200 kA RMS Sym., 50 kA at 500 Vdc
ET, EET, FE and FEE: 200 kA RMS Sym.,50 kA at 500 Vdc
Operating class aR
Agency information
Designed and tested to BS88 part 4 and IEC 60269 Part 4
UL Recognized*
CCC for ET, FE, EET, FEE
CE
35FE
40FE
35FE
45FE
50FE
63FE
71FE
80FE
90FE
100FE
500 Vac/dc (UL), 35 to 1600 A North American style bolted tags high speed fuses, for the protection of DC common bus, power converters/rectifiers and reduced rated voltage starters. Ratings Volts 500 Vac (UL) 500 Vdc (35-800 A only) Amps 35-1600 A IR 200 kA RMS Sym. 50 kA at 500 Vdc Agency information UL Recognized, JFHR2, E91958, FWH-_B (35-200 A) and FWH-_A (1000 and 1200 A), JFHR2, E56412 FWH-_A (225-800 A) CSA Class 1422-30, File 53787 (35-1600 A) CE FWH-35B FWH-40B FWH-45B FWH-50B FWH-60B FWH-70B FWH-80B FWH-90B FWH-100B FWH-125B FWH-150B FWH-175B FWH-200B FWH-225A FWH-250A FWH-275A FWH-300A FWH-325A FWH-350A FWH-400A FWH-450A FWH-500A FWH-600A FWH-700A FWH-800A FWH-1000A FWH-1200A FWH-1400A FWH-1600A
Supplier: Ndfeb magnet, magnetic assembly, ferrite magnets, smco, halbach array magnet, surge protection device, gas discharge tube, lightning protection earthing system, spd, gdt, arrester, surge, lightning
Supplier: Consumer electronics, industrial control, and high speed connectivity cables and connectors.
Services: Manufacturer, designing, customization for consumer electronics, industrial control, and high speed connectivity cables and connectors.
Buyer: Consumer electronics, industrial control, and high speed connectivity cables and connectors.
Supplier: Led lights, automotive led lights, led working light,jeep light, led strips,neon lights and other electronic products like switches, connectors,harness, usb car charger,fuses and so on.
Supplier: Steel structures, high voltage & low voltage, cables/accessories, electrical & instrumentation products, industrial pumps, electric motors and accessories, industrial valves, gear drives, vfd drives, soft starters, transmission couplings, ht and lt control panels, mcc panels, fasteners & welding consumables, scaffolding material, chemicals, irrigation spares.
Services: Engineering procurement company/merchant exporter
Supplier: Micro silica (silica fume), silica, fly ash, pozzolano, ggbfs and white cement, other cementatious materials and factory/plants specialized spare parts & equipments, automation & switchgear, drives & transmission spares, instrumentation & pump, pneumatic & hydraulic spares, valves & actuators, mechanical parts, high carbon ferro chrome, foundry pig iron, iron ore concentrate, chromite ore, antimony ore, silicon metal 441 (powder), ferro silicon (fesi), iron ore pellet, copper concentrate
Supplier: Low voltage power cables, mid voltage power cables, control cables, instrumentation and telecommunication cables, optical fiber cables, mine low voltage power cables, mine mid voltage power cables, rail transit communication cables, railway rolling stock cables, cables for use in photovoltaic systems, fireproof cable, low voltage power cables for shipboard and offshore, mid voltage cables for shipboard and offshore, control cables for shipboard and offshore, instrumentation and telecommunication cables for shipboard and offshore compensating extension cables and compensating cables, rubber sheathed cable, charging post cable, connecting cables for equipment, towline cables, high temperature resistant cable,esp power cable, (electrical submersible pump power cable), mining detection cable, logging cable, submarine power cable
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".