Fire Alarm Control Panel Conventional

Supplier From China
Mar-28-19

AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC
(resistive), 2.0 amps @ 30 VAC (resistive).

Price and Minimum Quantity

Price: $100
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Fire Alarm Control Panel Conventional

Mar-28-19
 
"AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Mar-28-19
 
AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC
(resistive), 2.0 amps @ 30 VAC (resistive).
Dec-26-17
 
2zone MINI Conventional Fire Alarm Control Panel Fire Alarm Host/Master Panel /Slave Panel

Product Features

1. 2 conventional input zones.
2. 1 notification appliance circuits (NAC) with built-in synchronization forANSI 3.41and Gentex.

3. The panel comes with a 2 amp power supply.
4.Dedicated alarm and trouble relays.
5.1 RS485 can be able to connect the other panel.
6. Housed in a 205mm W x 258mm H x 81mm D metal enclosure.
7. Enclosure supports two 12V, 4Ah backup batteries.
8.The panel can be used independently or connect by RS 485.
Specifications

Primary AC 120VAC 50/60 Hz Power supply rating
240VAC 50/60 Hz
Power supply rating 2 Amps @ 24VDC
Maximum Battery Charging Current 0.98 Amps @ 26VDC
Initiating Device Circuits 2 Zones Alarm Zone 2
Normal Initiating Operating Voltage 23VDC, Maximum 26VDC, regulated
Normal Quiescent Current (normal status)
Nov-28-16
 
1. General

Conventional Fire Alarm Control Panel with four Zones
2. Specifications



Two Style B (Class B) Initiating Device Circuits (IDCs).
All zones accept two-wire smoke detectors and any normally-open contact devices.
One built-in Fire Fighting Ouput.
24-volt operation.
Resettable four-wire smoke detector power 500 mA.
Non-resettable power 500 mA.
One-man walk-test programmable for silent or audible test.
Disable/Enable control per IDC.
Reverse polarity protection.


3. Packaging and shipping

Conventional Fire Alarm Control Panel with four Zones
1 pc/carton box;carton M:43*17*51cm
Oct-20-16
 
The 4001 non-addressable control and indicating equipment forms the central part of a fire detection and alarm
System. The 2-wire 4001 is compatible with numens non-addressable devices
The 4001 comes standard with features that allows flexibility and expandability. Default configuration programming
Facilitates out-of-box installation and rapid commissioning.
2, 4, 8, or 16 detection zones
Up to 32 non-addressable devices per alarm zone circuit
Configurable non-latching alarm zones, alarm dependency (zone coincidence detection), and output delay timer
3 access levels
Single-person test mode
Day/night mode
Manual activation of audio/visual alarm devices
Supervised auxiliary dc 24 v output
2 independently programmable non-addressable a/v alarm output circuits
2 programmable fire alarm relay outputs
Fault relay output
3 voltage-free inputs for remote reset, evacuation start/stop, and day/night mode
Supports up to 7 repeater panels
Dec-07-10
 
Power Supply: AC 240V 50/60Hz
Stand-by Battery: DC24V Sealed Maintenance-Free Lead-Acid Battery
Charging Voltage: DC26.4V Below 450mA Trickle Charging
Circuit Voltage: DC24V Short Circuit Voltage 5V below 32mA
Loop Resistance: Below 50+ back and forth
Detector Installation: No limit in the number of differential detector & constant-temperature detectors used; smoke detectors or electronic differential detectors; each ciruit can connect to a maximum of 16 smoke detectors (monitoring current for detectors: DC24V 40¦A)
Terminal Resistor: 10k+
Number of indicators: 1 time the number of panel circuits
Number of Local Alarm: 1 time the number of panel circuits.


Number of circuit & Dimension:
1L/2L/4L/5L/8L (330x280x120mm)
12L/16L(400x300x120mm)
24L(495x300x120mm).
Mar-28-19
 
AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC
(resistive), 2.0 amps @ 30 VAC (resistive).
Aug-23-16
 
The 6001 analogue addressable control and indicating equipment forms the central part of a fire detection and alarm

System. The fully networkable 2-wire 6001 is compatible with numens addressable devices and can also be

Connected to non-addressable devices when used with addressable input modules.

Default configuration programming facilitates out-of-box installation and rapid commissioning. A powerful and versatile

Cause-and-effect pc-based programming tool enables rapid customization with software for sites that require

Special operating features.

The 6001 comes standard with features that allows flexibility and expandability.

Single loop or 2-loop options available
Single loop, expandable to 2-loops available
Networkable, up to 4 control panels
Up to 125 addressable devices per loop
Automatic device detection on start-up
Automatic device type-code verification
2 independently programmable non-addressable a/v alarm output circuits
2 programmable fire alarm relay outputs
Fault relay output
Backlit lcd display providing 4 rows of 40 characters
16 zone fire alarm led indicators
3000 event history log
Mar-28-19
 
AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC
(resistive), 2.0 amps @ 30 VAC (resistive).

Verification Status