Please click here to check who's online and chat with them.

Peak Load & Displacement Indicator

Supplier From India
Mar-14-19

To configure the machine, connect the power supply. Now press TARE key(K4) and with the TARE key(K4) pressed power on the Machine (switch connected to the Main Load Vs Displacement PCB). It shows Now use the INCREMENT key(K2) & SHIFT key(K3) to enter the Password given to you & then press the ENTER key(K1). If your Password is wrong it will display Sorry

Price and Minimum Quantity

Price: $137
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Peak Load & Displacement Indicator

May-10-19
 
Technical characteristics:
Safe load indicator JL-3000 uses industrial grade 5.7 inch LCD screen;
 Full patch design, waterproof, dust-proof, anti-vibration, small size and easy to disassemble;
 The casing is made of high-pressure cast aluminum material, beautiful, and the protection level is strong;
 Large-scale digital, analog CMOS integrated circuits, low power consumption; strong anti-interference ability, high reliability;
 The system has automatic fault detection function, which can automatically determine the fault location;
 The host adopts the touch button, long service life and high reliability;
 The system uses the latest modular integrated chip. Software can adjust the gain, the hardware without potentiometer, to solve the drift problem caused by the temperature change of the potentiometer, thus ensuring the stability of the dataï¼?
 With password setting to prevent parameter wrong settingï¼?
 With sound and light alarm functionï¼?
 Automatic compensation for sensors, 'temperature drift' and 'null drift'ï¼?
 With black box function, convenient to inquire any time.
VERIFIED
Dec-21-13
Buyer From Vadodara, Gujarat, India
May-14-04
Supplier From Jaipur, Rajasthan, India
Feb-24-09
 
Glass tube rotameters

Thermacol packing.
Feb-24-09
 
Flowtech instrument services provides a range of glass tube/acrylic body rotameters. These rotameters are used for the measurement of fluid/gas flow rate through pipelines. Following are some of the technical features of these rotameterthe rotameter has linear scale accuracy with 10:1 rangeability. It has face height 500 mm and two tone powder coating and low cost with fastest delivery.The rotameter operates on variable cross section area of the glass tube [metering tube]. Various constructional features of this rotameter are: the device has a unique design to withstand tough quality conditions. This metering tube is shielded from all sides with clear front and rear visibility. Gland packing construction provides tension free tube installation and perfect stoppage of leaking. The tube and float are easily interchangeable. Various options are available for construction and materials of construction of wetted parts for a wide range of applications. Flowtech instruments services offers these from 15 nb to 80 nb and flange between 2.5 lph to 2000 lph of water and 0.1 to 200 nm3/hr of air.

Thermacol packing.
May-25-20
 
A12E indicator for small scale such as bench scale, platform scale
Feb-18-25
 
Temperature gauge WTZ-280 0-100â??
Our company mainly serves thermal power plants, hydroelectric power plants, metal mines, coal mines, steel plants, cement plants, petroleum, chemical, natural gas industry. All along, our company serves for many domestic large-scale construction projects to provide a lot of supporting services with first-class quality product, preferential and thoughtful service. We have set a good image and credibility to our customers. We hope to cooperate with domestic and foreign partners in the related areas.

Yoyik can offer many spare parts for power plants as below:

#DF-Temperature gauge WTZ-280 0-100â??-DF
LVDT Sensor ZD-3000TDB
BENTLY Preamplifier 330180-91-05
thermal resistance WZP2-430(K)
pressure switch BH-003025-003
Speed sensor A5S0DS0M1415B50-5M
LVDT Converter DET300A
Limit switch (feedback box) ALS-200M2
pressure switch types 403212-SGLGY7
LVDT Sensor 3000TDGN-100-01-01
Coal flow sensor XD-TH-2
Speed sensor ZS-04-075-3000
Digital LED Indicator Voltmeter 20-380VAC, Ammeter 100A, for mounting in the hole fi 22mm, red color and with current-carrying transformer
Bolt electric heating rod ZJ-22-42
Speed increase relay IL100-03-T
pt rh thermocouple TE-404
LOAD CELL 1000KG TYPE S MFG. STC-1000-07
Position feedback transmitter JNJVS4300-250
Bolt electric heating rod ZJ-20-43
Overvoltage signal relay RXM4LB2BD
Eddy Current Sensor PR6422/105-011
temperature sensor pt100 3 wire WZPK2-343
AC Voltage transducer S3-VD-3-15A40
magnetic displacement transducer TD-1 100MM
PROXIMITY SENSOR ZS-05
Eddy Current Sensor PR6423/003-020
Camera probe assembly EIIS-2-CP
rpm pickup sensor CS-1 L100
thermocouple WRKK2-2804K
GES6000 excitation system supporting display screen GES6000
Eddy Current Sensor PR6422/104-110
Fuse RT 18-32 [1A,2A,6A,10A]
Power module DF2000/01
BREAKER AUXILIARY SWITCH CONTACTS FK10-II-50
LVDT Sensor 7000XS-4097
sensor SDJ-SC-2H
CT BDCTAD-01
Temperature gauge WTZ-280 0-100

ZYR-DFYL-2025-2-18
Aug-16-07
 
Pwm charging
Direct, boost and float auto-charging modes.
Optimized control for intelligent adjustment of control parameters based on actual charging / discharging rates.
Led indication of system working status.
Temperature compensation, high precision digital temperature transducer.
Over-load and short circuit protections.
Rated charging current: 20a, 30a, 40a
System voltage: 12v, 12/24v, 48a


As the same above
Oct-13-10
 
PTC thermistors current protector, also called PTC thermistor resettable fuses, protect load against over-current, overload, short circuit. No need for replacement, resume protective function after a short cooling-down time.
Ceramic PTC (positive temperature coefficient) thermistors are used instead of conventional fuses to protect load, such as motors, transformers, or electronic circuit, against overcurrent for circuit protection. PTC thermistor protector not only respond to inadmissibly high currents but also if a preset temperature limit is exceeded. PTC thermistor over-current protector limits the power dissipation of the whole circuit by increasing their resistance and thus reducing the current to a harmless residual value. In contrast to conventional fuses, PTC thermistor resettable fuses do not have to be replaced after elimination of the fault but resume their protective function immediately after a short cooling-down time.
PTC Thermistor Over-current Protector Application

It applies in the over-current overload and short circuit protection of transformers, battery charger, switches, switch power supply, adaptor, meter, instrumentation, apparatus, electronic coils, control panels, air conditioner, automotive electron, etc.

Operating Principle of PTC Thermistor for Overload Over-current Protection

The operating principle is as indicated in the following. When a circuit is in the normal status, the current through PTC is lower than the rated current and PTC thermistor protector is in the normal state with small resistance value, which will not affect the normal operation of the protected circuit. In case of some fault in the circuit and the current is greater than the rated current, the PTC thermistor protector will become hot quickly and present a high resistance state, which sets the circuit relatively "off" to protect the circuit from damage. After the fault is removed, PTC thermistor protector will automatically restore its low resistance state and the circuit will resume normal operation.

Normally, when PTC thermistor is used as an overcurrent protection component, it is preferred to select maximum operating current, maximum operating voltage and proper specifications. Furthermore such factors should be taken into consideration as the dimensions of the components, rated zero-power resistance, operating temperature range, etc.

Verification Status