Please click here to check who's online and chat with them.

O2-A3 Semiconductor Oxygen Sensor (O2 Sensor)

Supplier From China
Nov-27-18

O2-A3 Oxygen Sensor O2 Sensor Description
Alphasense Oxygen sensors use capillary flow control.

Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications.

Standard galavanic sensors use lead for greatest reliability but fixed lifetime.

O2-A3 Oxygen Sensorsize:
20mm diameter, the industry standard size for portable gas detectors

O2-A3 Oxygen Sensor O2 Sensor Specifications
* Output: 60 to 85 μA @ 22'C, 20.9% O2
* Response time t90 : < 15 (s) from 20.9% to 0% O2
* Operating life: > 36 months
* Temperature range : -30 to 55 'C
* Pressure range : 80 to 120 kPa
* Humidity range : 5 to 95 % rh continuous
* Height : 17.4 mm (including foam ring)
* Weight: < 16 g

Price and Minimum Quantity

Price: $1
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: O2-A3 Semiconductor Oxygen Sensor (O2 Sensor)

GOLD Member
Mar-28-23
 
Our most advanced intelligent spot detectors, multi-criteria/multi-sensor devices use multiple sensors to detect various conditions in an environment sensing a wider range of fires with greater accuracy.

Features & Benefits:

Multi-Criteria/Multi-Sensor smoke detection
Unique ability to detect major elements of a fire
Highest nuisance alarm immunity
Advanced algorithms interpret and respond to multiple inputs
Dec-01-17
Supplier From Shenzhen, Guangdong, China
 
O2-M2 Oxygen Sensor Description
Alphasense Oxygen sensors use capillary flow control.

Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications.

Standard galavanic sensors use lead for greatest reliability but fixed lifetime.

Specifications
* Output: 80 to 120 uA @ 20.9% O2
* Response time t90: < 15 (s) from 20.9% to 0% O2


* Linearity: 0.6 % O2 deviation @ 10% O2
* Operating life: > 24 months
*Temperature range: -30 to 55 'C
* Pressure range: 80 to 120 kPa
* Humidity range: 5 to 95 % rh continuous
* Diameter: 20.0 mm (including label)
* Heigh: 17.4 mm (including foam ring)
* Weight: < 16g
GOLD Member
Jan-20-23
Supplier From Dhaka, Dhaka, Bangladesh
 
Honeywell BW Solo is a easy to service single-gas detector with BLE connectivity that provides real-time visibility into the status and safety of hazardous-area workers, helping companies respond faster, more knowingly and decisively to safety incidents. The first single-gas detector with the 1 Series sensor for CO, H2S and O2

Features & Benefits:
User-friendly operation,
Easy-to-read display for multiple languages,
Lightweight convenience,
Ease of maintenance,
Serviceability,
The new 1-Series sensor for enhanced reliability,
Connected Bluetooth Low Energy (BLE) capabilities.
Feb-27-17

O2S-Fr-T5 Oxygen Sensors

$1
MOQ: Not Specified
Supplier From Shenzhen, Guangdong, China
 
Features
* oxygen pressure range 2 mbar - 3bar
* zirconium dioxide (zro2 ) sensing elements
* non-consumption technology
* integral heating element
* no need for temperature stabilisation
* no reference gas required
* high accuracy
* linear output signal
* operates with external interface boards

Specifications
Heater voltage:
Porous cap (15mm): 4.35v dc +/- 0.1v dc (1.85a)
Stand by: 2v dc (0.85a)
Pump resistance @ 700'C: < 6kOhm
Permissible gas temperature: -100 to 250C
Gas flow rate: 0 to 10 m/s
Repetitive permissible acceleration: 5 g
Incidental permissible acceleration: 30 g
Feb-27-17
Supplier From Shenzhen, Guangdong, China
 
O2-a2 oxygen sensor

Performance
Output î¼a @ 20.9% o2 80 to 120
Response time t90 (s) from 20.9% to 0% o2 < 15
Zero current î¼a in n2 < 2.5
Linearity % o2 deviation @ 10% o2 0.6

Lifetime
Output drift % change in output @ 3 months < 1
Operating life months until 85% original output of 20.9% o2 > 24

Environmental
Humidity sensitivity % o2 change: 0% to 95% rh @ 40â?? < 0.7
Co sensitivity % (change o2 reading) / % co2 @ 5% co2 0.1
Pressure sensitivity (% change of output)/(% change of pressure) @ 20kpa < 0.1

Key specifications
Temperature range â?? -30 to 55
Pressure range kpa 80 to 120
Humidity range % rh non-condensing (0 to 99% rh short term) 5 to 95
Storage period months @ 3 to 20â?? (store in sealed pot, open circuit) 6
Load resistor î© (recommended) 47 to 100
Diameter mm (including label) 20.0
Height mm (including foam ring) 17.4
Weight g < 16

-
Mar-26-04
 
Thank you for purchasing and using our company's ultrasonic oxygen concentration / flow sensor.

1, please carefully read the instructions and fully understand the contents of the sensor after operation and maintenance. Improper use may cause damage to the sensor. (no violent impact and falling ground)
2, without the consent of the company, it is strictly prohibited to alter the structure and components of the sensor without authorization. The company is not responsible for any personal safety incidents or sensor abnormalities caused by unauthorized alterations.
3, the specifications and instruction contents of this sensor may be changed due to the technical improvement of the product.
4, this instruction manual must be handed to the actual user of the sensor and stored in it, and placed at any time where the actual user of the sensor can access it.
5, the company has the right to interpret the instructions for the sensor.

2ã??technical parameter
Measurement parameters measuring method range Resolution accuracy

O2 Ultrasonic 20.5%-95.6% 0.1% �±1.8%FS 5-45â??
Note: the range can be customized according to customer requirements.

Sample gas requirements Water removal (no condensation); dust filtration (
Dec-02-16
Supplier From Shenzhen, Guangdong, China
 
Features
* oxygen pressure range 2 mbar - 3bar
* zirconium dioxide (zro2 ) sensing elements
* non-consumption technology
* integral heating element
* no need for temperature stabilisation
* no reference gas required
* high accuracy
* linear output signal
* operates with external interface boards
* pcb mountable

Specifications
Heater supply*
Porous lid cap 4vdc +/- 0.1vdc (1.7a)
Stand by 1.65vdc (0.7a)
Full porous cap 4.35v dc +/- 0.1v dc (1.85a)
Stand by 2v dc (0.85a)
Dec-02-16
Supplier From Shenzhen, Guangdong, China
 
Features
* oxygen pressure range 2 mbar - 3bar
* zirconium dioxide (zro2 ) sensing elements
* non-consumption technology
* integral heating element
* no need for temperature stabilisation
* no reference gas required
* high accuracy
* linear output signal
* operates with external interface boards
* 80mm, 220mm and 400mm probes available

Specifications
Heater supply*
Porous lid cap 4v dc +/- 0.1v dc (1.7a)
Stand by 1.65v dc (0.7a)
Full porous cap 4.35v dc +/- 0.1v dc (1.85a)
Stand by 2v dc (0.85a)
Jun-02-17
Supplier From Shenzhen, Nanshan, China
 
Zirconia O2 Sensors
Probe Series - Short Housing

The Probe Range of zirconium dioxide oxygen sensors are available in three lengths. Suitable for aggressive and polluted applications such as boiler exhausts. Longer probes are an ideal solution for thicker walled, insulated flue pipes.

FEATURES
* Zirconium dioxide (ZrO2) sensing elements
* Long life, non-depleting technology
* Integral heating element
* High accuracy
* Requires an external interface board to operate

BENEFITS
* No reference gas required
* No need for temperature stabilisation
* Compact enclosure

TECHNICAL SPECIFICATIONS
Heater voltage
Operating (standard response) 4V DC ± 0.1V DC (1.7A)
Standby 1.65V DC (0.7A)
Operating (fast response) 4.35V DC ± 0.1V DC (1.85A)
Standby 2V DC (0.85A)
Pump impedance at 700'C < 6kΩ
Permissible gas temperature -100'C to +250'C
Gas flow rate 0 ~ 10 m/s
Repetitive permissible acceleration 5g
Incidental permissible acceleration 30g

OUTPUT VALUES
Oxygen pressure range 2mbar ~ 3bar max
Accuracy 5mbar max
Internal operational temperature 700'C
Response time (10 - 90% step)
Standard response sensor < 15s
Fast response sensor < 4s
Warm up time (prior to sensor operation) 60s
Warm up time (from standby) 20s
Output stabilisation time ~ 180s

Verification Status