Programmable Temperature and Humidity Test Chambers
3-Layers Temp Humi Test Chamber
Temperature Humidity Test Chamber
Temperature and Humidity Test Chambers provides an economical and space-saving solution for a variety of testing requirements. It can simulate different climatic conditions, such as heat-endurance, cold-endurance, dryness-endurance, and humidity-endurance, which defines the performance of material. By testing the product under different climatic conditions to see whether its performance can meet the intended requirements. It is widely applied in the industries of electron, electrical equipment, vehicle, metal, food, chemistry, building materials, luggage, adhesion tape, printing, packaging, and other product components and materials.
The programmer includes a temperature alarm as just one part of Grande's Three-tiered over-temperature protection system. A thermal fuse and a user-set independent limit are also included. In addition, a specimen power terminal allows the user to safely operate powered equipment inside or with the chamber.
Corresponding Standard of the Temperature and Humidity Test Chamber:
1.GB11158 high-temperature testing condition
2.GB10589-89 low-temperature testing condition
3.GB10592-89 high-low-temperature testing condition
4.GB/T10586-89 hu midity testing condition
5.GB/T2423.1-2001 low-temperature testing condition
6.GB/T2423.2-2001 high-temperature testing condition
7.GB/T2423.3-93 humidity testing condition
8.GB/T2423.4-93 alternating temperature testing machine
9.GB/T2423.22-2001 temperature testing method
10.IEC60068-2-1.1990 low-temperature testing method
11.IEC60068-2-2.1974 high-temperature testing method
12.GJB150.3 high-temperature test
13.GJB150.4 low-temperture test
14.GJB150.9 humidity test
Grande Expertise in Humidity Control
Controlling humidity in a small environmental chamber can be especially challenging. Grande expertise in humidity control brings intelligent design that is carefully integrated into the Criterion chambers. The humidity subsystems are designed for reliability, convenience, and performance:
An external steam generator allows expanded range and is easy to maintain.
A separate de-humidification coil improves low humidity control and range.
Wet-bulb humidity sensor is a �??primary measurement method�?? for accuracy. It is also economical, easy to maintain, and reliable because it has no risk of failure due to over-saturation. (Read why analog is preferred over digital.)
Direct water supply connection is standard, with options for water filtering and recirculating water tank.
Features
High performance and quiet operation (65 dBa)
Space-saving footprint, designed for flush installation to wall
Stainless steel exterior