1. Follow the specifications:
ASTM D5882 Standard Test Method for Low Strain Integrity Testing of Piles
JGJ106-2003 (China) Technical code for testing of building foundation piles


2. Parameters::
1). Size: 62 * 172 * 225 mm.
2). Weight: 2.0 kg.
3). High-contrast touch screen display.
4). Temperature range:
Operating Range: 0° to 40° C; Storage Range: -20° to 65° C.
5). Powered by internal battery (6 hours duration).

3. Functional:
1). The LPT-E is used for Integrity pile testing and judging defect position
2). Automatic data storage
3). Signal amplification capability
4). Data can be averaged over a variable number of blows.
5). Variable signal amplification over time
6). 24-bit A/D converter
7). Sample size: 4k
8). Sample Frequency: 48kHz, 96 kHz,144 kHz

Price and Minimum Quantity

Price: $1000 - $10000
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Low Strain Dynamic Pile Tester

Jun-23-16
 
1. Follow the specifications:
ASTM D4945 Standard Test Method for High-Strain Dynamic Testing of Piles
JGJ106-2003 (China) Technical code for testing of building foundation piles

2. Physical
(1) Size: 62 *172 * 225 mm
(2) Weight: 1.7 kg
(3) 8 inch and high brightness color LCD touch screen
(4) Temperature range: Operating: 0° to 40° C; Storage: -20° to 65° C
(5) The cables and connectors are suitable for PDA

3. Technical
(1) HPT used for determining the pile bearing capacity and pile integrity.
(2) It can be used for pile driving monitoring and the cast-in-place pile test.
(3) Sampling frequency is Optional of 10 kHz, 20 kHz, 30 kHz and 40 kHz.
(4) Sampling points are optional of 1024, 2048 and 4096. Maximum sampling time is up to 400 ms
(5) Before test the two accelerometers and two strain transducers are self-checked automatically, determine whether the system is in normal state.
(6) Automatically check the static strain deviation of the strain transducer during installation and adjusted to zero before blow.
(7) Test data exported through the external u-disk
(8) During test every blow can be saved automatically
(9) Storage capacity of more than ten thousands blows.
(10) HPT can be used for pile driving monitoring and the cast-in-place pile
(11) HPT data can save as *.X01(used for PDA-W)
(12) The main cable and connecting cable are compatible with the PDA.
(13) Built-in lithium battery can be used more than 5 hours continuously.
(14) PDAR program carry on CASE method analysis.
(15) RCAPWAP program carry on match analysis automatically or manually.
Jun-23-16
 
1. Follow the specifications:
ASTM D4945 Standard Test Method for High-Strain Dynamic Testing of Piles
JGJ106-2003 (China) Technical code for testing of building foundation piles

2. Physical
(1) Size: 62 *172 * 225 mm
(2) Weight: 1.7 kg
(3) 8 inch and high brightness color LCD touch screen
(4) Temperature range: Operating: 0° to 40° C; Storage: -20° to 65° C
(5) The cables and connectors are suitable for PDA

3. Technical
(1) HPT used for determining the pile bearing capacity and pile integrity.
(2) It can be used for pile driving monitoring and the cast-in-place pile test.
(3) Sampling frequency is Optional of 10 kHz, 20 kHz, 30 kHz and 40 kHz.
(4) Sampling points are optional of 1024, 2048 and 4096. Maximum sampling time is up to 400 ms
(5) Before test the two accelerometers and two strain transducers are self-checked automatically, determine whether the system is in normal state.
(6) Automatically check the static strain deviation of the strain transducer during installation and adjusted to zero before blow.
(7) Test data exported through the external u-disk
(8) During test every blow can be saved automatically
(9) Storage capacity of more than ten thousands blows.
(10) HPT can be used for pile driving monitoring and the cast-in-place pile
(11) HPT data can save as *.X01(used for PDA-W)
(12) The main cable and connecting cable are compatible with the PDA.
(13) Built-in lithium battery can be used more than 5 hours continuously.
(14) PDAR program carry on CASE method analysis.
(15) RCAPWAP program carry on match analysis automatically or manually.
Jun-23-16
 
1. Follow the specifications:
ASTM D5882 Standard Test Method for Low Strain Integrity Testing of Piles
JGJ106-2003 (China) Technical code for testing of building foundation piles


2. Parameters::
1). Size: 62 * 172 * 225 mm.
2). Weight: 2.0 kg.
3). High-contrast touch screen display.
4). Temperature range:
Operating Range: 0° to 40° C; Storage Range: -20° to 65° C.
5). Powered by internal battery (6 hours duration).

3. Functional:
1). The LPT-E is used for Integrity pile testing and judging defect position
2). Automatic data storage
3). Signal amplification capability
4). Data can be averaged over a variable number of blows.
5). Variable signal amplification over time
6). 24-bit A/D converter
7). Sample size: 4k
8). Sample Frequency: 48kHz, 96 kHz,144 kHz
Jun-23-16

Rebar Location System

$1.00K - $10.00K
MOQ: Not Specified
 
Purpose
SYR51+ rebar Location system is used to test rebar diameter, distribution, coating thickness in concrete.
Specification
JGJ/T152-2008
Performance
Longer service life of the Connector Clip: The instrument has long service life because of using Lemo Connector Clip which comes from Swiss and uses for aircraft industry.
Good quality of signal cable: The signal cable has long service life because of its flexible and substance.
High precision and stability: The instrument can locate the steel-bar accurately and quickly.
Longer service life of the sensor: Improve the service life by paste abrasion resistance allowance bottom of the sensor
Single sensor: No-change sensor in test, switching between high and low test range can assure the precision of test data and the test depth.
Display test information real-time: Display the test data directly to avoid man-made errors.
Grid and section scan mode: Instrument can display steel bar distribution and scan steel bar without concrete boundary limited.
Three-wheel steel-bar scan system: The system can assure scan path along line and the precision of test data.
Powerful Windows data process and analysis software: Software can display analysis result by diagram. Test data can be export to word or Excel easily.
Jun-23-16

Steel-Bar Corrosion Tester

$1.00K - $10.00K
MOQ: Not Specified
 
Purpose
The instrument is used to test the degree of steel-bar corrosion in electrochemical method.

Specification
GB50204-2002

Performance
1. Two test mode. The potentiometry and gradient method is used to test steel-bar corrosion which fit for different working field.
2. Permanent reference electrode. Saturated CuSO4 solution is sealed up completely in reference electrode. Field test keeps clean, simple and pollution-free operations.
3. Automatic measure environmental temperature. Instrument design to contain a measure environmental temperature module, it can measure, record and display environmental temperature quickly no thermometers required.
4. Can save test date. Convenient for laborer data management.
5. Display test result intuitively. Display test result used icon mode, The icon color is more dark, the steel-bar corrosion is more serious. User can observe the corrosion degree intuitively.
6. Real USB transmission. Data can be transmitted to computer for future process and analysis.
7. Powerful data process and analysis software in windows. Software can display analysis result by spectrum and isoline. Test data can be export to word or excel easily.

Performance
1. Test range: +/-2000 mV
2. Testing accuracy: +/-1 mV
3. Test point distance: 1~ 99cm setting
4. Applicable environmental:
Temperature: -10? ~ +40?
Dampness:
May-11-12
Supplier From Beijing, China
GOLD Member
May-08-17
 
The primary use of Ammonium Sulphate is as a fertilizer for alkaline soils. In the soil the ammonium ion is released and forms a small amount of acid, lowering the pH balance of the soil, while contributing essential nitrogen for plant growth. The main disadvantage to the use of Ammonium Sulphate is its low nitrogen content relative to Ammonium Nitrate, which elevates transportation costs.
It is also used as an agricultural spray adjuvant for water soluble insecticides, herbicides, and fungicides. There it functions to bind iron and calcium cations that are present in both well water and plant cells. It is particularly effective as an adjuvant for 2,4-D (amine), glyphosate and glufosinate herbicides.
GOLD Member
Dec-27-22
 
Product Features
The purity of the product, calcium and phosphorus ratio appropriate to ensure a higher degree of its biological effects. Phosphorus content greater than 21% of the products, their biological effects better. This unique high-tech companies use technology to make our products crystallization, high purity.
Drying process advanced products, products with low free water under the premise that the product does not lose crystallization of water, avoid the product in the drying process for the loss of water caused by crystallization of biological effects of the reduction.
coarse particles MDCP in the animals stay in the stomach longer and more conducive to the absorption of calcium phosphate, the product produced by micro-particles MDCP form, without any chemical binder.

Specifications
Appearance white powder or granule
Phosphate  21% min
Calcium     15% min
Fluorine    0.18% max
Arsenic    30ppm max
Pb   30ppm max

Source of OriginRock

Packing and Storage
Knitted bags lined polyethylene plastic bags
double packaging, Weighing 25Kg.
Transportation-and harsh rain.
Stored in a cool, ventilated, dry place.
GOLD Member
Dec-27-22
 
Monocalcium Phosphate (MCP) Feed grade

Product Features
The purity of the product, calcium and phosphorus ratio appropriate to ensure a higher degree of its biological effects. Phosphorus content greater than 22% of the products, their biological effects better.
This unique high-tech companies use technology to make our products crystallization, high purity and its harmful impurities significantly below
standards:HG28611997
Drying process advanced products, products with low free water under the premise that the product does not lose crystallization of water, avoid the product in the drying process for the loss of water caused by crystallization of biological effects of the reduction.

Specifications
Appearance white powder or granule
Total P 22%min
Ca 13-18%
F 0.18% max
As 10 ppm max
Pb 10ppm max
Moisture 4%max

Source of OriginRock

Packing and Storage Knitted bags lined polyethylene plastic bags double
packaging, Weighing 25Kg. Transportation-and harsh rain. Stored in a cool, ventilated, dry place

Verification Status