Automatic transfer switch is one of adopted international ATSE technology developed by our company. It is suitable for power supply system with rated insulating voltage is AC800V, rated working voltage is AC240/415V, and below DC250V, and AC 50Hz/60Hz, rated working current is 16A-3200A of two-path. The transfer switch and the matching intellect display, they are main used for high building, the post and communication, coal mining, shipping, military facilities industrial assembly line etc the situation of need the interruption power supply.
Generator Load Transfer Switch ATS for Diesel Generators
Radin Electric provides ATS design, engineering, and full after sales support for a wide range of automatic transfer switch applications. We offer onsite electrical audits to assist in determining the correct product and installation to meet your exact needs and requirements.
RDQ3NM Series Advantages:
1. There is a reliable mechanical interlock device and electric interlock protection between two MCCB, completely avoid the possibility of two MCCB closed at same time;
2. Intelligentized controller adopt the single chip microcomputer (SCM) as the control core, simple hardware, strong functions, easy extension, high reliability;
3. Intelligent controller circuit layout design adopt power sampling separate with SCM control, from the hardware to overcome the electromagnetic interference;
4. With short circuit, over load protection functions, over-volt & under-volt,phase missing auto transfer function and intelligent alarm function;
5. Auto transfer data by external setting freely, with operation motor protect function;
6. Signal connecting cable have passed FLUKE instrument channel test, anti near crosstalk,attenuation crosstalk and back wave loss, can meet the test criteria for permanent link;
7. The ATS controller installation method provide customer with highly autonomy, ( split installation only need simply connect the attached RJ45 signal cable to the corresponding terminal port);
Radin Electric provides ATS design engineering and full after sales support for a wide range of automatic transfer switch applications. We offer onsite electrical audits to assist in determining the correct product and installation to meet your exact needs and requirements.
a. Control power voltage AC 230V
b. Auto Transfer Auto transfer auto recovery auto transfer no auto recovery power grid generator
c. Manual transfer Manual main power manual backup power manual OFF
d. Isolation lock Off position have isolation function also can padlock locked
e. Generator control Generator start and stop
f. Fire linkage With passove fire linkage signal to switch OFF the device with one set passive NO feedback contact.
g. Display mode Mechanical indication device ON/OFF status operating mode
LED device ON/OFF status power status
LCD device ON/OFF status power status data setting
h. Setting mode Key press operation Chinese/English display interface can set the working mode low voltage value over voltage value delay time auto transfer mode etc.
i. Power monitoring ABC three phase over voltage (240 290v adjustable)
ABC three phase low voltage (150 200v adjustable)
ABC three phase missing monitor
j. Delay time Transfer delay (0 300s adjustable)
Recovery delay (0 300s adjustable)
Generator start stop delay (0 300s adjustable)
k. Mounting mode Integated mounting
Controller Type
A Basic type single phase monitor
B. Standard type threee phase monitor fire fighting generator control
C Intelligent type three phase monitor fire fighting generator control LCD display
D Intelligent type three phase monitor fire fighting generator control split LCD display
Load Change Over Switch ATS Power Switch for Generators
Radin Electric provides ATS design, engineering, and full after sales support for a wide range of automatic transfer switch applications. We offer onsite electrical audits to assist in determining the correct product and installation to meet your exact needs and requirements.
RDS2 series Auto changeover switch mainly used for distribution or electromotor network under 50Hz, rated voltage 380V, rated DC voltage 220V, and rated current 16A to 3200A, change over between main power and backup power, mutual work as backup power system and city power and Generator power. At the same time, it can act as disconnector for the un-frequency ON and OFF circuit or lines.
Such product are widely used in the power transmission and distribution system and atomization system of important site which power off is not allowed, such as fire-fighting, hospital, bank, high buildings etc.
RDS2 Auto Transfer Switch Equipment (ATSE), is integrate the switch and logical control together, no need extra controller, is an electromechanical integration auto transfer switch, with voltage monitoring, frequency monitoring, communication port, electrical and mechanical interlock functions etc., can achieve auto control, remote motor control and emergency manual control.
Operation is achieve by logical control board with various logical commands to managing the motor, gear-box running, motor with spring energy storage, instant release accelerating mechanism, quickly open and close the circuit or make quick transferring, through visible status to make sure the safety isolation, greatly improved the every electrical and mechanical performance.
RDS2 ATS integral designed with metal case, compact and strong.
RDS2 ATS, the control part is with metal cover, switch part with DMC case, have strong dielectric performance, protection performance and reliable operation safety.
The switch suitable for auto transfer between main power and backup power system or two load equipment's auto transfer and safe isolation etc.
The switch has beautiful appearance, novelty, small size, complete functions, is the best choose among the similar products.
RDS2 series product have passed the EMC test.
Radin Electric  provides ATS design, engineering, and full after sales support for a wide range of automatic transfer switch applications. We offer onsite electrical audits to assist in determining the correct product and installation to meet your exact needs and requirements.
Technical Specification
Model RDQ3-63
Working Voltage AC150-265V Â 50/60Hz
Operation Mode Auto and Manual
Transfer Mode Auto Transfer with Auto Recovery
Transfer time delay 0.2s Fixed / 0~30s adjustable
Rated Current 6A to 63A Â 3P and 4P
About ATS
RDQ3-63 is CB type dual power transfer switch,mainly apply to the two power systems with neutral line earthed and rated current below 63A, rated voltage 230V,50/60Hz, transfer between two power source when one power source fault,to ensure the power supply reliable and safety.
Product Structure
RDQ3-63 Series ATS usage category AC-33IB,electrical appliance grade CB class,its structure comprise with two MCB and accessories,mechanical interlock transmission mechanism,automatic controller,motor operation mechanism etc.Meanwhile the MCB inside the ATS have its original over load and short circuit protection function,can also used as ON/OFF and protection of the main circuit.
Load Change Over Switch ATS Power Switch for Generators
Radin Electric provides ATS design, engineering, and full after sales support for a wide range of automatic transfer switch applications. We offer onsite electrical audits to assist in determining the correct product and installation to meet your exact needs and requirements.
RDS2 series Auto changeover switch mainly used for distribution or electromotor network under 50Hz, rated voltage 380V, rated DC voltage 220V, and rated current 16A to 3200A, change over between main power and backup power, mutual work as backup power system and city power and Generator power. At the same time, it can act as disconnector for the un-frequency ON and OFF circuit or lines.
Such product are widely used in the power transmission and distribution system and atomization system of important site which power off is not allowed, such as fire-fighting, hospital, bank, high buildings etc.
RDS2 Auto Transfer Switch Equipment (ATSE), is integrate the switch and logical control together, no need extra controller, is an electromechanical integration auto transfer switch, with voltage monitoring, frequency monitoring, communication port, electrical and mechanical interlock functions etc., can achieve auto control, remote motor control and emergency manual control.
Operation is achieve by logical control board with various logical commands to managing the motor, gear-box running, motor with spring energy storage, instant release accelerating mechanism, quickly open and close the circuit or make quick transferring, through visible status to make sure the safety isolation, greatly improved the every electrical and mechanical performance.
RDS2 ATS integral designed with metal case, compact and strong.
RDS2 ATS, the control part is with metal cover, switch part with DMC case, have strong dielectric performance, protection performance and reliable operation safety.
The switch suitable for auto transfer between main power and backup power system or two load equipment's auto transfer and safe isolation etc.
The switch has beautiful appearance, novelty, small size, complete functions, is the best choose among the similar products.
RDS2 series product have passed the EMC test.
RDQ3NX-A/B/C/D series ATS is our company introduced to the market on 2009, effectively solved the problems of MCB type ATS 's insufficient functions, poor reliability, un-convenient replacement etc., this product have three patent certificates ( Invention patent, Utility models patent, Appearance patent), C/D series is a new type introduced to market on 2010, this product have complete functions, concept innovation, is a unique product among the similar products.
Product Structure
RDQ3-63-A/B/C/D series ATS comprised with two MCB and accessories, mechanical interlock system, intelligent controller etc. Product have A, B,C,D four type control construction, A type is basic type ( Only provide with auto change auto recovery, phase missing protect, auto/manual control), B type is intelligent type( including the A type functions and have Generator start, fire linkage, time delay functions), C and D type is improved type, increased three phase voltage monitoring function on A and B type. This ATS series circuit breaker keeps the original breaker's overload and short circuit protection function.
RDQ3NX Series Advantages:
1. Product with modularized design, executive unit, transmission mechanism, control circuit completely independent, easy for replacement.
2. Mechanical transmission device adopt gear transmission, completely eliminate the possibility of closing at same time;
3. Compact appearance, it is one of the smallest product on the market;
4. The control circuit layout adopt working power and sampling power separate with single chip control, to overcome the electromagnetic interference from the hardware construction;
5. Working power voltage range: AC200-400V;
6. Less power consumption, max. peak power loss 4.8W, only 20% of other similar products;
7. Product have complete functions, with generator start, fire linkage, ON delay functions etc.;
8. Modularized design, good components interchange performance, easy installation;
9. Can use various executive circuit breaker;