Functions s a DC insulation and AC coupling device(decoupler), RE is used for preventing the flow of the CP current up to a predetermined voltage threshold, while passing any induced AC current. For voltage that attempts to exceed the threshold, the device instantly switches to the shorted mode, providing over-voltage protection.
This stray current is normally caused by AC fault current or lightning current and other interference. The standard threshold voltage is -2V / +2V. The threshold voltage is absolute or peak, When the voltage is switched at this scope, it is the sum of the DC and the peak AC voltage across the terminals of the device. This results in a very low ,and safe, clamping voltage across the terminals.
Applications:
1. Decouple gradient control mats (grounding mats) from pipelines.
2. Over-voltage protection of equipment from AC faults, lightning, and switching transients (e.g. insulated joints).
3. Decoupling dissimilar metals that must otherwise be AC bonded for safety.
4. AC grounding and DC isolation of electrical equipment integral to a cathodically protected system.
5. Mitigation of induced AC voltage.
Capability:
1. Blocking voltage or threshold voltage;
2. DC leakage current for a given blocking voltage;
3. AC fault current rating;
4. Lightning surge current rating;
5. Steady-state AC current rating.
Supplier: Cathodic protection products, pipeline fittings, pipeline set-on weights, pipeline solid decoupler, pipeline warning tape, pipeline casing insulator
Supplier: Main products are stainless steel, stainless steel tank, fermentation tank, storage tanks, tank of extraction, enzymatic hydrolysis tank, cosmetic box, emulsifying tank, extraction tank, drying tower, multifunctional mixing tank, reaction tank and other clean cabinet electric heating equipment, provide the concentration of extraction, separation, solvent recovery and so on chinese native .microbial fermentation engineering, such as bacterial culture, liquid fermentation, solid fermentation, non standard fine biochemical equipment design, production, installation, automatic cip;aseptic pipeline, process cleaning equipment, plc automatic remote control, etc.
Supplier: Cable ties, terminal blocks, circuit breaker, panels meter, proximity switch, solid state relay.
Supplier: Pressure transmitter, transducer, pressure indicator, linear transducer, linear potentiometer, lvdt transducer, displacement transducer, linear scale, melt pressure transducer, solid state relay, pid controller, proximity sensor, load cell, thermocouple, signal conditioner, hot runner temperature controller (hrtc panel), modular controller, digital panel meter, thyristor power regulator, hmi, force transducer, ac drive, servo drive, power regulator, single ended bending beam, power analyzer, synchronization meter, data logger, recorder, signal transducer, temperature and humidity transducer