Please click here to check who's online and chat with them.

Urodynamic Measuring System

Supplier From India
Dec-17-11

Models

• Urocomp 2000
Uroflow + Cystometry
• Urocomp 2000E
Uroflow + Cystometry + Emg
• Urocomp 2000U
Uroflow + Cystometry + UPP
• Urocomp 2000 EU
uroflow + cystometry + EMG + UPP + Video + Gynaecology study.


1 number.

Price and Minimum Quantity

Price: Negotiable
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Urodynamic Measuring System

GOLD Member
Nov-29-20
 
One Touch Ultra Test Strips are for use with the One Touch Ultra and OneTouch UltraSmart Meters for quantitatively measuring glucose in whole blood. Fast test time of 5 seconds.

OneTouch Ultra Test Strips are for blood glucose testing with the OneTouch Ultra Family of Meters, and the InDuo Systems.

Tiny blood sample (1 microlitre)

End-fill strip automatically draws in blood

Indicator window shows when you have enough blood

Touchable strip

Easy-open flip-top vial for use with the One Touch Ultra brand and InDuo meters only.
May-10-20
 
8''All Infrared Detection Body Temperature Intelligent Fast Face Recognition Android all-in-one machine
Suitable for scenic spot,office,hotel,school,shopping mall,community or any other places require auto face recognition.
Jun-02-20
 
7ich screen
4gb capacity core
200w piexl camera
GOLD Member
Feb-26-25
Supplier From Seongnam-si, Gyeonggi-do, South Korea (Republic Of Korea)
 
The ASL Skin and Hair Mobile Innovation Analysis System is a mobile innovation analysis system by Aram Huvis, designed to assess skin and hair conditions. This portable system combines advanced technology for real-time analysis, making it a convenient solution for personalized skincare and hair care diagnostics. The device aims to provide accurate, on-the-go assessments for both professional and personal use.

Hair Solutionist ASL-202 Measures:
1.Hair Loss Status
2. Scalp Status
3. Hair Density
4. Keratin of Scalp
5. Sensitivity
6. Hair Thickness
7. Hair Pore Status

Video MJPEG Streaming Solution:
- VGA (640 x 480) | 30 FPS Max
- 2 M (1600 x 1200) | 15 FPS Max

Automatic Remote Control Analysis:
- Start | Mode Change Image Capture l Analysis l Result

Multi OS Support:
Android | Mac OS | iOS | Windows

SPECIFICATION:
- Wi-Fi Type : Wireless LAN IEEE 802.11 b/g/n
- OS Support : Android, iOS, Windows, Mac OS
- Image Sensor: 1/4 inch Color CMOS UXGA (2 Mega Pixel)
- Sensor Pixel : Effective pixel : 1,624 X 1,212 Pixel
- Image Capture Size : Wi-Fi Video Streaming VGA (640 X 480)
- Image Frame Rate : VGA (640 X 480) - 30 Frame Max
2 M (1,600 X 1,200) - 15 Frame Max
- LED : Dip LED X8
- Camera Button Function : Start, Mode Change, Image Capture, Analysis, Result
- High Magnification Lens :
1. X 60 - NL
2. X 60 - PL
3. X 200 - NL (Crop)
4. X 200 - PL (Crop)
- Focusing : Fixed Type
- Battery : Type: Li-ION / Typical Capacity: 1,150 mAh
- Normal Voltage: 3.7 V
- DC IN Adaptor: 5V DC / 2A
- Out Dimension: 69(W) X 100(H) X 22(D )mm (API-100)
- Weight: About 100 g (with Battery)
- Cradle : Stand
Aug-25-22
 
Product description
Partial discharge inspection instrument is a digital partial discharge charged detection instrument designed by our company based on years of experience in partial discharge measurement. It adopts two emerging technologies, ultra high frequency (UHF) measurement and ultrasonic (US) measurement. This system uses modern electronic and computer integrated technology to realize signal amplification, filtering, data acquisition, data processing, partial discharge parameter calculation, map drawing, and automatic generation of test reports, thereby completing the intelligent measurement and analysis of partial discharge. This device adopts handheld design and Wince system development; the device is lightweight, convenient to carry, fast to measure, and easy to use on the spot; it has friendly interface, simple operation, and high refresh rate; and the device has complete functions, strong anti-interference ability, and accurate measurement. This instrument has no damage to the power equipment to be tested during the testing process, and has no impact on the operation of the equipment. According to the maps obtained by the multiple detection modes of the UHF and US methods, the diagnostic analysis of the detection of insulation defects or hidden dangers of power equipment can be performed to clearly determine the operating status of the power equipment.



Technical index

Host parameters

Number of interfaces

2 interfaces 1 UHF interface 1 US interface

Sampling accuracy

12bit

Way of synchronization

Internal synchronization,External synchronization,

Light synchronization

UHF parameters

Measurement frequency range

300MHz-1.5GHz


Output method

Output with SMA head

Receiving method

Receive with antenna

Transfer method

Coaxial cable

Sensitivity

70dB

Mean sensitivity

50dB

Dynamic Range

80dB

Hardware

Display screen

4.3 TFT true color LCD screen

Resolution

480 272
VERIFIED
May-03-19

Onetouch Select Plus Simple

$10
MOQ: Not Specified
Supplier From New Delhi, Delhi, India
 
The OneTouch® Selectâ?¢ Plus Blood Glucose Monitoring System is intended to be used for the quantitative measurement of glucose (sugar) in fresh capillary whole blood samples drawn from the fingertip.

The system is intended to be used by a single patient and should not be shared. The OneTouch® Selectâ?¢ Plus Blood Glucose Monitoring System is intended for self-testing outside the body (in vitro diagnostic use) by people with diabetes at home and with their healthcare professionals in a clinical setting as an aid to monitor the effectiveness of diabetes control.

The OneTouch® Selectâ?¢ Plus Blood Glucose Monitoring System is not to be used for the diagnosis of or screening of diabetes or for neonatal use. The system is intended to be used by a single patient and should not be shared.

Test Principle

Glucose in the blood sample mixes with the enzyme Glucose Oxidase (see page 130) in the test strip and a small electric current is produced.

The strength of this current changes with the amount of glucose in the blood sample. Your meter measures the current, calculates your blood glucose level, displays the blood glucose result, and stores it in its memory. Use only OneTouch® Selectâ?¢ Plus Control Solutions and Test Strips with the OneTouch® Selectâ?¢ Plus Meter.
Nov-28-17
Supplier From Shenzhen, Guangdong, China
 
The Herpes Simplex Virus Rapid Test is a rapid qualitative lateral flow test designed for the quantitive detection of IgG antibodies to Herpes Simplex Virus (HSV) in human serum/plasma samples.

HSV-1 is usually associated with infection in oropharyngeal area and eyes, while HSV-2 causes mostly genital and neonatal infections (5, 6), however, the tissue specificity is not absolute (7). HSV-2 can be isolated occasionally from the oropharynx and 5-10% of primary genital infections may be caused by HSV-1. Infants infected with HSV appear normal at birth, but almost invariably develop symptoms during the newborn period (5, 8, 9). Neonatal HSV infection may remain localized or become disseminated. Localized infection may involve one or a combination of sites. These are skin, eyes, mouth or the central nervous system. Disseminated infection is manifested by pneumonitis, hepatitis, disseminated intravascular coagulopathy and encephalitis. Of the infants with neonatal HSV, about one half of those surviving will develop severe neurological or ocular sequelae. A number of serological procedures have been developed to detect antibodies to HSV. These include complement fixation, indirect immunofluorescent antibody, plaque neutralization, and ELISA (6, 8, 10). Antibody of the IgG class is produced during the first 2-3 weeks of infection with HSV and exists only transiently in most patients. Serologic procedures, which measure the presence of IgG antibodies, help discriminate between primary and recurrent infections, since IgG antibodies is rarely found in recurrent infections. High affinity IgG antibodies to HSV, if present in a sample, may interfere with the detection of IgG specific antibody (9). High affinity IgG antibody may preferentially bind to HSV-1 antigen leading to false negative IgG results. Also, rheumatoid factor, if present, along with antigen specific IgG, may bind to IgG causing false positive IgG results. Both problems can be eliminated by deactivating IgG in the sample before testing for IgG.
Apr-30-21
Supplier From Hong Kong
VERIFIED
Dec-27-19
 
Bayer Contour Plus Strips 50 Count

The Bayer Contour plus test strips are used with the Bayer Contour plus blood glucose monitoring system for the quantitative measurement of glucose (sugar) in fresh capillary whole blood samples drawn from the fingertips

Verification Status