Please click here to check who's online and chat with them.

Vibration Meter

Supplier From China
May-30-08

Vibration meter

Vibration meter series
Used for measuring periodic motion, to check the imbalance and deflecting of moving machinery .
We have the vibration meters with frequency of 0.1 to 10 khz, accuracy less than 5%, ac output 2.0v peak full scale .The operating conditions is 0c~45c/ 0~40c(32f~104f), <90% or =90%rh
Cable and software for rs-232c interface .

Price and Minimum Quantity

Price: Negotiable
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Vibration Meter

Nov-09-10
 
Acceleration 10Hz-1KHz 0.1-400m/ms+  0.3-1312ft/ms+ 
10Hz-10KHz 0.1-400m/ms+  0.3-1312ft/ms+ 
Velocity 10Hz-1K 0.1-400mm/s 0.004-16.0inch
Displacement 10Hz-1KHz 0.001-4.0mm 0.04-160 mil
Accuracy:++5%
Auto power off
RPM(revolution):5-100000r/min
Frequency:0.1 to 10KHz
Metric/imperial conversion
With RS232C interface
Max hold
Operating conditions:0-+45f+(32=¬-104=¬),f-90%RH
Power supply:4x1.5V AAA(UM-4)battery
Battery indicator: low battery indicator
Optional accessories: RS-232C cable & software:
1.USB adaptor for RS-232C
2.Bluetooth interface




Dimensions : 124x62x30mm
Weight: 120g(not including battery)
Nov-10-10
 
Application:
Used for measuring periodic motion, to check the imbalance and deflecting of moving machinery.Is pecifically designed for present measuring various mechanical vibration. So as to prove the data for the quality control, run time and equipment upkeep.
Iuse the high-performance acceleration meter, realize the repetitiveness and accurate measurement.It has the function of testing axle bearing situation.
Specifications:
Acceleration 0.1-200m2/s (10Hz to 1KHz 10Hz to 10KHz )
Velocity : 0.1-200mm/s0. (10Hz to 1KHz)
Displacement: 0.001-2.0mm(10Hz to 1KHz)
Accuracy:·+5¼t
Auto power off
Max hold
Operating conditions:0-+40f¦(32+H-104+H),f_90%RH
Power supply: 4x1.5V AA(UM-3)battery
Battery indicator: low battery indicator



Dimensions : 160x68x32mm
Weight: 181g(not including battery)
Nov-10-10
 
Specifications
Display: 4 digits LCD, backlit
Range: 0~1250 »m/0~50mil
(other ranges can be specified )
Min.radius workpiece: F: Convex 1.5mm/Concave 25mm
N: Convex 3mm/ Concave 50mm
Min. measuring area: 6mm
Min.Sample thickness : 0.3mm
Resolution: 0.1 »m (0~99.9»m);
1 »m (over 100»m)
Accuracy: f+1~3%n or 2.5 »m or 0.1mil
(Whichever is the greater)
Bttery Indicator: Low batter indicator.
PC interface: with RS-232C interface
Power supply: 2x1.5 AAA(UM-4) battery
Operating condition: Temp. 0~50f¦ .
Humidity <95% .

Standard accessories:
Carrying case ...................1 pc.
Operation manual ............ 1 pc.
F probe in built .................1 pc.
NF probe in built...............1 pc.
Calibration foils ..............1set.
Substrate (Iron) ................1 pc.
Substrate (Aluminium)......1 pc.
Optional accessories: RS-232C cable & software:
1.USB adaptor for RS-232C
2.Bluetooth interface




Size: 126x65x35 mm; 5.0x2.6x1.6 inch
Weight: about 81g(not including batteries)
Nov-10-10
 
Features
Used in production site to measure surface roughness of various machinery-processed parts, calculate corresponding parameters according to selected measuring conditions and clearly display all measurement parameters.
Specifications
Displayª 4 digits, 10 mm LCD, with blue backlight
Parameters: Ra, Rz
Display Range
Ra: 0.05-10.00um/1.000-400.0uinch
Rz: 0.020-100.0um/0.780-4000uinch
Accuracy: Not more than 10%
Fluctuation of display value: Not more than 6%
Sensor :
Test Principle: Inductance type
Radius of Probe Pin: 10um
Material of Probe Pin: Diamond
Measurement Force of Probe: 16mN(1.6gf)
Probe Angle: 90fp
Vertical Radius of Guiding Head: 48mm
Maximum driving stroke: 17.5mm/0.7inch
Cutoff length (l): 0.25mm / 0.8mm / 2.5mm optional
Evaluation length: 1~5 cut off optional
Driving speed:
sampling length = 0.25mm Vt=0.135mm/s
sampling length = 0.8mm Vt=0.5mm/s
sampling length = 2.5mm Vt=1mm/s
returning Vt=1mm/s
Resolution : 0.001¬ªm if reading ·+10¬ªm
0.01¬ªm if 10¬ªmf_reading·+100¬ªm
0.1¬ªm if reading fª100¬ªm
Power Li-ion battery: rechargeable
Operating conditions: Temp. 0-50f¦
Humidity <80%

Attachment:
Standard Sensor RP-100
Groove Stylus SRP-110
curvature Probe SRP-120
Extension Rod SER-150
Mesurement Stand SRS-1
Standard Sample Plate SSP-180
Cable and Software for RS-232/USB)
Bluetooth interface



Size·ª140x57x48 mm (5.5x2.2x1.9 inch)
Weight: about 420 g
Nov-10-10
 
Features
This instrument is compatible with four standards of site to measure surface roughness of various machinery-processed parts, calculate corresponding and clearly display all measurement parameters.
When measuring the roughness of a surface, the sensor is placed on the surface and then uniformly slides along the surface by driving the mechanism by the sharp built-in probe. This roughness causes displacement of the probe which results in change of inductive amount of induction coils so as to generate
Specifications
Display·ª 4 digits, 10 mm LCD, with blue backlight
Parameters: Ra, Rz, Rq, Rt
Measuring Range
Ra, Rq: 0.005-16.00um/0.020-629.9uinch
Rz,Rt: 0.020-160.0um/0.078-6299uinch
Accuracy: f_f+10%
Fluctuation of display value: Not more than 6%
Sensor :
Test Principle: Inductance type
Radius of Probe Pin: 5um
Material of Probe Pin: Diamond
Dynamo-measurement of Probe: 4mN(0.4gf)
Probe Angle: 90fp
Vertical Radius of Guiding Head: 48mm
Maximum driving stroke: 17.5mm/0.7inch
Cutoff length (l): 0.25mm / 0.8mm / 2.5mm optional
Evaluation length: 5l
Driving speed:
sampling length = 0.25mm Vt=0.135mm/s
sampling length = 0.8mm Vt=0.5mm/s
sampling length = 2.5mm Vt=1mm/s
returning Vt=1mm/s
Profile digital filter
Filtered Profile: RC
Filtered Profile: PC-RC
Filtered Profile: Gauss
Non-Filtered Profile: D-P
Resolution : .001¬ªm if reading ·+10¬ªm
0.01¬ªm if 10¬ªmf_reading·+100¬ªm
0.1¬ªm if reading fª100¬ªm
Evaluation length : 5 cut-off
Power Li-ion battery: rechargeable
Operating conditions: Temp. 0~50f¦
Humidity <80%
Attachment:
Standard Sensor RP-100
Groove Stylus SRP-110
curvature Probe SRP-120
Extension Rod SER-150
Mesurement Stand SRS-1
Standard Sample Plate SSP-180
Cable and Software for RS-232/USB)
Bluetooth interface




Size·ª140x57x48 mm (5.5x2.2x1.9 inch)
Weight: about 420 g
May-28-08
Supplier From Guangzhou, Guangdong, China
Jul-26-16
 
Applications:
*Measture the cast iron thickness,aluminum thickness,quartz glass thickness,PVC thickness,PE thickness,red copper thickness etc.

Details:
Case Material: Aluminum Alloy
Operating Principle: Ultrasonic
Measuring Range (metric / Imperial):0.75~400 mm ( 45 # steel, Depend on Probe )
Sound Velocity: 500~9,990 m/s
Resolution:0.01 mm / 0.1 mm
Accuracy: � (0.5%n + 0.05)

For more details,please do not hesitate to contact us.Thank you!
Oct-31-19
Buyer From Chittagong, Chittagong, Bangladesh
Apr-13-20
Supplier From Qingdao, Shandong, China

Verification Status