Tita-Prosthesis Piston Type Loop (Piston)

Supplier From India
May-01-25

Tita-prosthesis Piston type Loop (PISTON)

Both Pistons consists of a flat band loop and shaft, used for Stapedioplasty surgery. These prosthesis are connected between â??Long Processâ?? of Incus and the Footplate. In Malleus Stapedioplasty, the piston requires to be bent at the neck and this titanium loop easily facilitates this requirement which is not possible in the commonly used Teflon piston.

Design Benefits
Only one Piston is required for a Stapedioplasty surgery as the length can be cut as per requirement.
Malleable enough to facilitate bending at the neck for Malleus Stapedioplasty.
Stable design provides maximum sound output.
Offers best possible length selection.
Easy loop introduction.
Low risk of osteo-necrosis.
Tita-PTFE Piston can be easily cut due to PTFE shaft.
Tita Piston is MRI Compatible.
Both Pistons can be trimmed by using Osseous Cutter

Price and Minimum Quantity

Price: $00 - $00 / Box (EXW)
MOQ: Not Specified
Product Grade: ASTM F136

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Tita-Prosthesis Piston Type Loop (Piston)

Jun-21-20
Supplier From New Delhi, Delhi, India
 
ISO 9001:2015 & ISO 13485:2016 Certified CE Approved.
Complete Nebulizer Kit Included For Effecative Medication Delivery.
Heavy Motor For Longer continuous usage.
Easy to Clean & Light Weight.
One-Button Operation.
Easy carry handel.
GOLD Member
May-17-21
 
Technique Parameter

Oxygen flow rate .. 1L-5L
Oxygen concentration .. 93% + 3%
Rated voltage / Power .. AC220+V 22V ,50Hz + 1Hz
Material .. Plastic
Oxygen concentration .. 0.5-3L/min + 90%
Flow fluctuation .. 0.7L/min
Atomization amount .. + 0.2ml/min
environment temperature .. 5-40
humidity range .. 80%
Atmospheric pressure range .86kpa -- 106kpa
Size .. L448*W245*H492
Weight .. 14.5g


1. Headset type components (optional)
2. Nasal tube assembly (optional)
3. Atomizer assembly
GOLD Member
May-16-21
 
Technique Parameter

Oxygen flow rate .. 1L-5L
Oxygen concentration .. 93% + 3%
Rated voltage / Power .. AC220V + 22V ,50Hz + 1Hz
Material .. Plastic
Oxygen concentration .. 0.5-3L/min 90%
Flow fluctuation .. 0.7L/min
Atomization amount .. 0.2ml/min
environment temperature .. 5-40
humidity range .. 80%
Atmospheric pressure range .. 86kpa -- 106kpa
Size .. L448*W245*H492
Weight .. 14.5g

1. Headset type components (optional)
2. Nasal tube assembly (optional)
3. Atomizer assembly
May-01-25
 
Super Tita-PTFE Vario Piston type Loop

Super Titanium is a kind of material which can be bent and twisted but it always returns to its original shape. Unique flat loop design of Super Titanium material provides self crimping (elastic properties) attachment to Incus and also provides uniform attachment of loop around total periphery of Incus which reduces the risk of compressive necrosis. A superelastic property of loop reduces the surgical process time and crimping difficulties.

Design Benefits
More elastic titanium material for self crimping effect.
Elastic self crimping loop shortens the time of surgery.
Stable design provides maximum sound output.
Reduced risk of osteo-necrosis.
Super Titanium Piston is MRI Compatible.
Super Tita-PTFE Piston can be easily cut due to PTFE shaft.
Simplified loop introduction to Incus by easy downward movement.
Both Pistons can be trimmed by using Osseous Cutter.
May-01-25
 
Tita-PTFE Vario Piston type Loop

Both Pistons consists of a flat band loop and shaft, used for Stapedioplasty surgery. These prosthesis are connected between â??Long Processâ?? of Incus and the Footplate. In Malleus Stapedioplasty, the piston requires to be bent at the neck and this titanium loop easily facilitates this requirement which is not possible in the commonly used Teflon piston.

Design Benefits
Only one Piston is required for a Stapedioplasty surgery as the length can be cut as per requirement.
Malleable enough to facilitate bending at the neck for Malleus Stapedioplasty.
Stable design provides maximum sound output.
Offers best possible length selection.
Easy loop introduction.
Low risk of osteo-necrosis.
Tita-PTFE Piston can be easily cut due to PTFE shaft.
Tita Piston is MRI Compatible.
Both Pistons can be trimmed by using Osseous Cutter.
GOLD Member
Apr-02-22

510S Ventilator

$12.00K - $13.00K
MOQ: 100  Pieces
Sample Available
 
Tidal Volume 0-2000ml
Venlitation Modes A/C-V with Sigh, A/C-P
Patient Type Adult, Child, Infant (3.5)
Apnea back-up ventilation Manual breath
Inspiration flow Max.90 /min
Flow trigger 2-30 L/min
One Battery run time Minimum 4.5 hours
Product Size 168mm* 156mm * 300mm Weight: 8kg
HS code 9031809090
GOLD Member
Jan-23-24

Zimmer M/l 12/14 Taper Hip Prosthesis Femoral

$700 - $900
MOQ: 10  Pieces
Sample Available
 
The Zimmer M/L Taper Hip Prosthesis is a product line from Zimmer Biomet, a company that specializes in orthopedic implants and devices. The M/L Taper Hip Prosthesis is used in hip replacement surgeries and consists of a femoral stem that is implanted into the patient's femur.

The "M/L 12/14 Taper" designation likely refers to the taper of the femoral stem, with 12/14 indicating the taper size. The "Standard Offset" specification suggests a standard offset design for the femoral stem. The offset refers to the distance between the center of the femoral head and the center of the femoral stem. Standard offset is a common configuration, but there are also variations such as high offset or low offset stems to accommodate different patient anatomies.

Key features and considerations for the Zimmer M/L Taper Hip Prosthesis may include:

Material: The femoral stem is typically made of biocompatible materials such as titanium or cobalt-chromium alloy.

Taper Design: The taper design facilitates the connection between the femoral stem and the femoral head component.

Modularity: Some hip prostheses, including those with taper connections, offer modularity, allowing surgeons to choose different head sizes and neck lengths to optimize patient fit.

Surgical Technique: Implantation involves removing the damaged part of the hip joint and replacing it with the prosthetic components.

Range of Motion: The design aims to provide stability, durability, and a suitable range of motion for the patient.
GOLD Member
Jan-25-24

Ev3 Spiderfx

$100 - $190
MOQ: 10  Boxes
Sample Available
 
The "SpiderFX" may refer to a specific type of embolic protection device used during carotid artery stenting procedures. Embolic protection devices are designed to capture and remove debris released during the stenting process to prevent it from traveling to the brain, reducing the risk of stroke.
GOLD Member
Jan-23-24

Ethicon 8702H 7 0 Prolene

$1.00K - $1.60K
MOQ: 1  Boxes
Sample Available
 
The Ethicon 8702H is a specific type of suture produced by Ethicon, a subsidiary of Johnson & Johnson and a leading manufacturer of surgical sutures and other medical devices. The product you mentioned, "7-0 Prolene Suture," refers to a specific size and type of suture.

Here are some key details about the Ethicon 8702H 7-0 Prolene Suture:

Suture Material: Prolene is the brand name for a synthetic, non-absorbable monofilament suture material made of polypropylene. Monofilament sutures like Prolene are smooth and reduce tissue drag, making them suitable for various surgical applications.

Size: The "7-0" designation indicates the size of the suture. In this case, it is a very fine suture. Suture sizes are denoted numerically, with smaller numbers indicating larger sizes.

Color: The "blue" in "blue monofilament" indicates the color of the suture. Suture colors are used to enhance visibility during surgery.

Non-Absorbable: Prolene sutures are non-absorbable, meaning they do not break down or dissolve over time. This characteristic makes them suitable for applications where long-term tissue support is required.

Indications: Prolene sutures are commonly used in various surgical procedures, including cardiovascular, ophthalmic, and plastic surgery. The choice of suture material and size depends on the specific requirements of the surgical procedure.