Advantages:
1.Excellent Chemical Resistance: The PFA pipette tips exhibit remarkable chemical stability, resisting corrosion from harsh chemicals like acids, bases, and organic solvents. This ensures consistent performance and accuracy in demanding laboratory environments.
2.Wide Temperature Range: These pipette tips can withstand a broad temperature range from -200�°C to 260�°C, making them suitable for both low- and high-temperature applications.
3.High Precision and Accuracy: The PFA pipette tips offer precise and accurate dispensing of liquids, ensuring consistent and reliable results in laboratory experiments.
4.Low Background Values: With low metal element content (such as lead and uranium) of less than 0.01ppb, these pipette tips are suitable for high-sensitivity analytical techniques like ICP-MS and trace analysis.
5.Customizable Options: The pipette tips are available in different sizes and can be customized to fit various pipette models, meeting the specific needs of different laboratories.
Durable and Reusable: The excellent stability of PFA material allows these pipette tips to be used repeatedly over a long period, reducing the need for frequent replacements and saving costs.
6.Easy to Clean: The smooth surface and precise manufacturing of these pipette tips ensure easy cleaning and minimal residue, maintaining the accuracy and reliability of the tips.
7.Transparent and Easy to Observe: The transparent design allows users to easily observe the liquid level inside the pipette tip, making it convenient for accurate dispensing.

In summary, the PFA pipette tips from Nanjing Binzhenghong Instrument Co., Ltd. are an excellent choice for laboratories requiring high chemical resistance, precision, and accuracy in liquid handling applications.

Price and Minimum Quantity

Price: $9
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier

More Items Similiar to: Chemically Inert Pfa Tips

GOLD Member
Oct-14-24
Supplier From North York, Ontario, Canada
 
Silicone Fluid is used mainly as an intermediate for the production of a wide variety of products in the chemicals and industries. Fluid is intended for use in a variety of medical applications including; lubricant for plastic or rubber devices and instruments, inert protective coating and water repellent film on the skin, and a hydrophobic surface on glass and ceramic substrates.
Silicone Fluid 350

WC Code: 19-122-01
Sales Specifications

Appearance: Liquid
Visc Cstks (cSt): 332.5- 367.5
HCL PPM (ppm): 0 - 5
WGT Loss (%): 0.5 Max.
REF Index @25C: 1.4013- 1.4053
Spec Gravity (g/cm): 0.965- 0.973
D4: < 1000 ppm
D5: < 100 ppm
Packing

441 lb drum, 4 drums per pallet
Silicone Fluid 1000

WC Code: 19-122-02
Sales Specifications

Appearance: Liquid
Visc Cstks (cSt): 950.0 - 1050.0
HCL PPM (ppm): 0 - 5
WGT Loss (%): 0.5 Max.
REF Index @25C: 1.4013-1.4053
Spec Gravity (g/cm): 0.967- 0.975
PPM Silanol (ppm): 0.0 = 600.0
D4: < 1000 ppm
D5: < 100 ppm
Packing

441 lb drum, 4 drums per pallet
VERIFIED
Aug-10-23

Diapharm Valve

MOQ: Not Specified
Supplier From Ernakulam, Kerala, India
 
Areas where highly corrosive materials are used in the chemical process and plants. Industries where the critical application like food, pharma and fine chemicals.
To control environment pollution.
FEATURE
Best quality in class with excellent performance.
Excellent corrosion resistance to the chemicals.
Maintenance Free/Long Service life cycle/Easy Installable,
ensuring cost reduction in production and maintenance.
QUALITY CONTROL
High Voltage electric spark test-all lined components.
Standard Hydraulic Test (15 kg/cm') of Body and seat (10 kg/cm')
Virgin lining materials used-FEP/PFA.
Size: 15 NB to 150 NB
LINNING
Thickness
Spark Test
Type
Service
Temp.
: 3.0 to 3.5mm Mini. Over all wetted parts.
: 15k.v.D.C.
: Teflon FEP/PFA
: Teflon (FEP) Max-160C
: Teflon (PFA) Max-205C
VERIFIED
Aug-10-23

Plug Valve

MOQ: Not Specified
Supplier From Ernakulam, Kerala, India
 
Areas where highly corrosive materials are used in the chemical process and plants.
Industries where the critical application like food, pharma and fine chemicals.
To control environment pollution.
FEATURE
Best quality in class with excellent performance.
Excellent corrosion resistance to the chemicals.
Maintenance Free/Long Service life cycle/Easy Installable, ensuring cost reduction in production and maintenance.
QUALITY CONTROL
High Voltage electric spark test-all lined components.
Standard Hydraulic Test (15 kg/cm') of Body and seat (10 kg/cm³)
Virgin lining materials used-FEP/PFA.
Size: 25 NB to 150 NB
LINNING
Thickness
Spark Test
Type
Service
Temp.
: 3.0 to 3.5 mm Mini. Over all wetted parts.
: 15k.v.D.C.
: Teflon FEP/PFA
: Teflon (FEP) Max-160'C
: Teflon (PFA) Max-205'C
VERIFIED
Aug-10-23

Butterfly-Valve

MOQ: Not Specified
Supplier From Ernakulam, Kerala, India
 
Areas where highly corrosive materials are used in the chemical process and plants. Industries where the critical application like food, pharma and fine chemicals. To control environment pollution. FEATURE Best quality in class with excellent performance. Excellent corrosion resistance to the chemicals.

Maintenance Free/Long Service life cycle/Easy Installable, ensuring cost reduction in production and maintenance. QUALITY CONTROL High Voltage electric spark test-all lined components.

Standard Hydraulic Test (15 kg/cm3) of Body and seat (10 kg/cm3) Virgin lining materials used-FEP/PFA. Size: 40 NB to 350 NB LINNING Thickness: Spark Test : 3.0 to 3.5 mm Mini. Over all wetted parts. 15k.v.D.C. Teflon FEP/PFA Type

Service :

Temp. : Teflon (FEP) Max-160�°C Teflon (PFA) Max-205�°C
VERIFIED
Aug-10-23

Ball-Valve

MOQ: Not Specified
Supplier From Ernakulam, Kerala, India
 
Areas where highly corrosive materials are used
in the chemical process and plants.
Industries where the critical application like food,
pharma and fine chemicals.
To control environment pollution.
FEATURE
Best quality in class with excellent performance.
Excellent corrosion resistance to the chemicals.
Maintenance Free / Long Service life cycle / Easy
Installable,
ensuring cost reduction in production and
maintenance.
QUALITY CONTROL
High Voltage electric spark test - all lined
components.
Standard Hydraulic Test (15 kg/cm\') of Body and
seat (10 kg/cm�³)
Virgin lining materials used-FEP/PFA.
Size: 15 NB to 200 NB
LINNING
Thickness :3.0 to 3.5 mm Mini. Over all wetted parts.
Spark Test :15k.v.D.C.
Type
Service
:Teflon�® FEP/PFA
:Teflon (FEP) Max-160�°C
Temp. :Teflon (PFA) Max-205�°C
VERIFIED
Aug-10-23

Ball-Check-Valve

MOQ: Not Specified
Supplier From Ernakulam, Kerala, India
 
Areas where highly corrosive materials are used in the chemical process and plants. Industries where the critical application like food, pharma and fine chemicals.
To control environment pollution.
FEATURE
Best quality in class with excellent performance.
Excellent corrosion resistance to the chemicals.
Maintenance Free/Long Service life cycle / Easy Installable,
ensuring cost reduction in production and maintenance.
QUALITY CONTROL
High Voltage electric spark test-all lined components.
Standard Hydraulic Test (15 kg/cm\') of Body and seat (10 kg/cm�³)
Virgin lining materials used-FEP/PFA.
Size: 15 NB to 150 NB
LINNING
Thickness
Spark Test
Type
Service
Temp.
: 3.0 to 3.5mm Mini. Over all wetted parts.
: 15k.v.D.C.
: Teflon FEP/PFA
: Teflon (FEP) Max-160 C
: Teflon (PFA) Max-205 C
Jun-12-24
 
The PFA pipette tips offered by Nanjing Binzhenghong Instrument Co., Ltd. possess numerous advantages that make them an excellent choice for various applications. Here are some of the key benefits:
Advantages:
1.Excellent Chemical Resistance: The PFA pipette tips exhibit remarkable chemical stability, resisting corrosion from harsh chemicals like acids, bases, and organic solvents. This ensures consistent performance and accuracy in demanding laboratory environments.
2.Wide Temperature Range: These pipette tips can withstand a broad temperature range from -200°C to 260°C, making them suitable for both low- and high-temperature applications.
3.High Precision and Accuracy: The PFA pipette tips offer precise and accurate dispensing of liquids, ensuring consistent and reliable results in laboratory experiments.
4.Low Background Values: With low metal element content (such as lead and uranium) of less than 0.01ppb, these pipette tips are suitable for high-sensitivity analytical techniques like ICP-MS and trace analysis.
5.Customizable Options: The pipette tips are available in different sizes and can be customized to fit various pipette models, meeting the specific needs of different laboratories.
Durable and Reusable: The excellent stability of PFA material allows these pipette tips to be used repeatedly over a long period, reducing the need for frequent replacements and saving costs.
6.Easy to Clean: The smooth surface and precise manufacturing of these pipette tips ensure easy cleaning and minimal residue, maintaining the accuracy and reliability of the tips.
7.Transparent and Easy to Observe: The transparent design allows users to easily observe the liquid level inside the pipette tip, making it convenient for accurate dispensing.

In summary, the PFA pipette tips from Nanjing Binzhenghong Instrument Co., Ltd. are an excellent choice for laboratories requiring high chemical resistance, precision, and accuracy in liquid handling applications.
Apr-01-20

All Teflon Cartridge Filter. Pfa Filter

$50
MOQ: Not Specified
Supplier From Hangzhou, Zhejiang, China
 
PFA filters using expanded PTFE membranes
and PFA core and cage, will meet all kinds of critical
filtration requirement in the most aggressive
environments.The filters have great corrosion
resistance and durability in highly corrosive acids,
bases and organic environment. Ideally suited for
corrosive chemicals and gases filtration in the
semiconductor industry. Its advanced fluid dynamics
design provide enhanced lateral flow across, through
and out of the membrane, which allows the high
permeability property of the membrane to be fully
utilized, result to improve flow rates and extend
service life over conventional filters.
Apr-17-25
 
An ergonomic handle hook design for easy grip in the palm.
Unique design for the tip eject button.
A clear reading window.
The pipete can be half autoclaved at 121 C.
A tip one made of durable chemical materials,
with excellent chemical corrosion resistance.
Ease of calibration and maintenance.
Availability for high temperature and high pressure.
disinfection of part of the device.