Specification
Strength/ Size
Packing Size
Packed In
Filariasis Kit
Includes One test
Strip, Desiccant and
Dropper
50 Strip
Test Per
Pack
50
Box Pack
Product Details: Number of Reactions(Preps)/Kit : 10T Brand : CTK BioTech Result Time (Rapid Kits) : 15 min Sample Type : Blood Test Type : Rapid Test CAT No : AR0151C Use of conserved antigens allows pan-filaria tests to be applicable Simple procedure provides alternative to diagnosis by blood smear Use serum, plasma or whole blood No restrictions on time of day for sample collection Each kit contains: Individually sealed foil pouches containing: One cassette device One desiccant Plastic droppers Sample diluent (1 bottle, 5 mL) One package insert (instruction for use)
COVID-19 Rapid Test Kit IgG + IgM (Colloidal Gold) comes in packs of 40 tests and contains: GCMS manufactures COVID-19 antigen test kit, the GENEDIA W COVID-19 Ag which is listed on the EU common list, also with GMP and ISO certifications. GENEDIA W COVID-19 Ag is unaffected based on the in-silicon analysis of the mutations in the nucleocapsid (N gene) of Omicron viruses. Letter of statement is available upon your request. To get over COVID-19 pandemic, especially the recent Omicron breakout, currently we are doing big promotions for three kinds of COVID-19 Ag kit. All are in stock and available right away. 1. Nasopharyngeal 2. Nasal 3. Saliva Price and Minumum Quantity Price FOB in USD: negotiable 0.8 to 1.8Minimum Order Qty: None Pieces Production Capacity: 3,000,000/monthPackaging: 20 Tests/kit, 30 Kits/box, 12 Boxes/pallet Sample: Available. Sample Cost Born By Supplier Product Model And Origin Brand: GENEDIAModel: 643G-S (Saliva) Seller Code: Genedia w covid 19 agHS Code: 3002.15 Standards: Ce Competitive Advantages Allow wider testing with fast test time (10 minutes) All necessary materials provided / no equipment needed Sensitivity: 93.33%, specificity: 100% Free sample. no moq. price is negotiable. customized packing. Other Details 20 tests / kit 24 months from the date of manufacture 2 ~ 30c(35.6 ~ 86f) available for room temperature deliver In stock. fast delivery. 1 x Instructions for Use Manual 40 x Test Cassettes 1 x Buffer 40 x Dropper
Covid-19 Self Test Kit We are the authorized first vendor of ADTech! KFDA CE approved, FDA Pending Price : Negotiable Pre-Clinical Test Report Accuracy - In total samples 93.3% (14/15) - In positive samples 91.7% (11/12) 1. Pre-Clinical Test summary 1) Pre-clinical test is fulfilled by Domestic large clinical laboratory with ADTech COVID-19 IgM/IgG RAPID KIT 2) Tests are made by total 15 samples with 12 positive and 3 negative samples 3) Clinical Laboratory tested the sample with Immunofluorescence Analysis 2. Pre-clinical test result 1) Samples were tested by ADTech COVID-19 IgM/IgG RAPID KIT 2) Test result by ADTechs RAPID KIT - 4 negatives and 11 positives results in 15 samples 3) Comparison between Immunofluorescence analysis and ADTechs RAPID KIT - 14 test results are same(including negative and positive results) - 1 samples test result are different(Positive Negative by ADTech
For in vitro qualitative detect of Covid-19 antigen in nasal(NS) swab specimens directly from individuals who are suspected of COVID-19 by their healthcare provider within the first 5 days of the onset of the symptoms. This test is only provided for use by clinical laboratories or to healthcare workers for point-of-care testing, and not for at home testing. 1.Easy to collect samples simple operation without professional equipment. 2.The test results are available in 15 minutes, and the test results are clearly visible. 3.Convenient transportation and low price, higher accuracy. 4.Suitable for large-scale rapid screening. Shelf life: 24 Months Test Result time: 10 Mins Packing: 25 Pieces per Box
The Typhoid IgG/IgM Rapid Test is a lateral flow immunoassay for the simultaneous detection and differentiation of anti-Salmonella typhi (S. typhi)G and IgM in human serum or plasma. It is intended to be used as a screening test and as an aid in the diagnosis of infection with S. typhi. Any reactive specimen with the Typhoid IgG/IgM 2.0 Rapid Test must be confirmed with alternative testing method(s).
The Cytomegalovirus Rapid Test is a rapid qualitative lateral flow test designed for the quantitive detection of Cytomegalovirus (CMV) in human serum/plasma samples. Cytomegalovirus is a herpes virus and a leading biological factor causing congenital abnormalities and complications among those who receive massive blood transfusions and immunosuppressive therapy. About half of the number of pregnant women who contract a primary infection, spread the disease to their fetus. When acquired in-utero, the infection may cause mental retardation, blindness, and/or deafness. Serological tests for detecting the presence of antibody to CMV can provide valuable information regarding the history of previous infection, diagnosis or active or recent infection, as well as in screening blood for transfusions in newborns and immuno-compromised recipients. The Cytomegalovirus Rapid Test Device (Serum/Plasma) has been designed to detect CMV through visual interpretation of color development in the internal strip. The membrane was immobilized with antigens of CMV on the test region. During the test, the specimen is allowed to react with colored recombinant mouse anti-human IgM latex conjugates, which were precoated on the sample pad of the test. The mixture then moves on the membrane by a capillary action, and interact with reagents on the membrane. If there were enough CMV antibodies in specimens, a colored band will from at the test region of the membrane. Presence of this colored band indicates a positive result, while its absence indicates a negative result. Appearance of a colored band at the control region serves as a procedural control. This indicates that proper volume of specimen has been added and membrane wicking has occurred.