An Earth Leakage circuit breaker (ELCB) (now referred to as residual current circuit breaker-RCCB) is a safety device used in electrical installation with high earth impedance to prevent shock. High Quality circuit breaker (ELCB’S) Manufacturer and Exporters provides Automatic models as well as manual models ELCB’s.
Earth leakage circuit breaker
The elcb is micro controller based with shock guard which continuously displays all the parameters and with inbuilt seven segment display and indicates the reason for tripping.
brand new Eaton KD3350 Series 3 Industrial Circuit Breaker with 3 poles and a rating of 350A at 600V. It is a premium quality product from a reputable brand and is designed for use in industrial automation and motion control applications. The breaker is compatible with the Automate controller platform and is perfect for use in PLC processors
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity (Icn): 6kA
Leakage protection trip type: Electronic /Electromagnetic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life : 4000 Times
Type of residual current: A/AC
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity( Icn): 6kA
Release Type of Leakage Protection: Electronic
Rated working current In: 6-40A
Rated working voltage (Ue): AC 230V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life :4000 Times
Residual current type: A/AC
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity (Icn): 6kA
Leakage protection trip type: Electronic /Electromagnetic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Type of residual current : A/AC
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N/3P+N
Rated short circuit breaking capacity (Icn): 6kA
Leakage protection trip type: Electronic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Type of residual current: A/AC
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity (Icn): 4.5kA
Release Type of Leakage Protection: Electronic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Residual current type: A/AC
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity (Icn): 10kA
Release Type of Leakage Protection: Electronic /Electromagnetic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Residual current type: A/AC