NFC 33209 0.6/1 kV Aerial bundled Cable ABC Cable
NFC 33209 0.6/1kV Aerial bundle Cable ABC Cable XLPE Insulated Cable
ABC Cable Application
NFC 33209 0.6/1kV Aerial bundle Cable ABC Cable XLPE Insulated Cable is the overhead insulated cable, used as public lighting wire or testing wire etc.
Aerial bunched cable 0.6/1kV is extensively installed in urban and forest region which provides the safety and reliance for public power distribution network.
ABC Cable Characteristics
Rated Voltage Uo/U (Um) :0.6/1kV (1.2kV)
Temperature Rating: Operation temp.:90 Short Circuit Temp.:250
Minimum Bending Radius:Single core: 13Ã??OD; Multi-core: 6OD(min) while 12OD during installation
ABC Cable Construction
Aerial Bundle Conductor(ABC)
Aerial Bundled Conductors (Phase Core): Circular, Class 2 stranded conductor, round compacted or non-compacted AAC conductor, AAAC conductor, or ACSR.
Aerial Bundled Conductor Messenger or Neutral Core:Circular, Class 2 stranded conductor, round compacted or non-compacted AAAC conductor (All Aluminium Alloy Conductor), AAC conductor(all aluminium conductor); ACSR conductor(Aluminium Conductor Steel Reinforced conductor),
Neutral Core Sizes: 54.6mm2, 70mm2, 95mm2
ABC Conductor Lighting Conductor:Circular, Class 2 stranded conductor, round compacted or non-compacted AAC conductor, AAAC conductor, or ACSR
Aluminium conductors ABC standard as per NF C 32-013, IEC 228 & IEC 228A
LV Aerial Bundled Cable Insulation
Overhead Conductor (ABC) Insulation: Low Density Polyethylene (LDPE), High Density Polyethylene(HDPE), XLPE(cross-linked polyethylene ), Polyvinyl chloride(PVC).
Aerial Bunch Cable Standard
As one of leading ABC Cable suppliers, we produce aerial bunched cables meeting NFC 33029, IEC60228, NF C 32-013ï¼?NFC 32 013, AS/NZS 3560.1,BS 7870-5,ANSI/CEA S-76-474,NTP 370.254 etc
1.Application The NFC33-209 Standard AAAC Conductor Aerial Cable is used for 600V or lower overhead service applications such as power transimission and distribution for street lighting,outdoor lighting,and temporary service for construction. The operating temperatures should not to exceed 75°C for polyethylene(PE) insulated conductors or 90°C for crosslinked polyethylene(XLPE)insulated conductors. 2.Standard : NFC33-209,BS7870,GB/T12527-2008 3.Rated voltage : 1kV,10kV or 11kV 4.Specification Concentric strand Aluminum/ AlloyAAAC wires insulated by PE or XLPE as phase conductor, bare or insulated AAC/AAAC/ACSR/AACSR messenger
http://www.xlpecable.com/zmscable/abc_272_1.html
ABC Cable Aerial Bundle Cable
http://www.xlpecable.com/zmscable/abc_272_1.html
1.Application The NFC33-209 Standard AAAC Conductor Aerial Cable is used for 600V or lower overhead service applications such as power transimission and distribution for street lighting,outdoor lighting,and temporary service for construction. The operating temperatures should not to exceed 75°C for polyethylene(PE) insulated conductors or 90°C for crosslinked polyethylene(XLPE)insulated conductors. 2.Standard : NFC33-209,BS7870,GB/T12527-2008 3.Rated voltage : 1kV,10kV or 11kV 4.Specification Concentric strand Aluminum/ AlloyAAAC wires insulated by PE or XLPE as phase conductor, bare or insulated AAC/AAAC/ACSR/AACSR messenger
http://www.vericable.com/cables/overheadcable/92.htm
1.Application The NFC33-209 Standard AAAC Conductor Aerial Cable is used for 600V or lower overhead service applications such as power transimission and distribution for street lighting,outdoor lighting,and temporary service for construction. The operating temperatures should not to exceed 75°C for polyethylene(PE) insulated conductors or 90°C for crosslinked polyethylene(XLPE)insulated conductors. 2.Standard : NFC33-209,BS7870,GB/T12527-2008 3.Rated voltage : 1kV,10kV or 11kV 4.Specification Concentric strand Aluminum/ AlloyAAAC wires insulated by PE or XLPE as phase conductor, bare or insulated AAC/AAAC/ACSR/AACSR messenger