Please click here to check who's online and chat with them.

Harness Probe Pogo Pin Chz136-H(8.4)

Supplier From China
Mar-08-22

Harness Probe Pogo Pin CHZ136-H(8.4) for the Tests of Automotive Industry

Harness probes are mainly used directly or for the tests of automotive industry. Parts of them are also applied to communication electronics, medical equipment, equipment automation, etc. The standard and requirements for them are high compared with other test probes. Harness probes can be divided into screw-thread harness probes, harness switch probes, non-screw-thread harness probes, position-limited harness probes and high-current harness probes, etc.

The CHZ136 harness probe we will introduce here is 1.36 mm in diameter and 33.4 mm in total length. Its barrel is made of brass plated with gold and nickel. The plunger is made of nickel-plated beryllium copper, which is softer but less magnetic than the alternative SK4. The spring inside is made of music wire plated with gold and nickel.

This probe can withstand up to the current 3 Amps. Its typical maximum contact resistance is 50 milliohms. It is suggested the plunger be pressed at a distance of 4.3 mm at most when this probe works, although the plunger can move as far as 6.4 mm. Otherwise, the spring inside the barrel will probably be damaged under constant pressure. When the plunger is pressed at a distance of 4.3 mm, its loaded force is about 113 gf, namely 4 ounces or so. Furthermore, the force fluctuates in a range due to the tolerance.

Technical Specifications
Recommended
Current Rating:   3 Amps, continuous
Contact Resistance: 50 milliohms
Full Stroke: 6.4 mm
Rated Stroke: 4.3 mm
Spring Force: 113 ±33 gf (4 oz) @ load 4.3 mm

Materials (plated)
Barrel: Brass, Au on Ni Plated
Plunger: BeCu, Ni Plated
Spring: SW-A/B, Au on Ni Plated

Company Information
Centalic Technology Development Ltd. was founded in 1980. Specializing in R&D, manufacture, sales and technical service, Centalic is one of the earliest high-tech enterprises which concentrates on large-scale production of various test probes and precision metal parts, and has a professional manufacturing base owning complete production lines and test equipment.

Our products include semiconductor test probes, in-circuit test probes, radio frequency probes, harness probes, battery contact probes, switching probes, big-current probes, spring probes, universal complex test probes, wafer probes, and so on. They are widely applied to the tests of various electronic products, such as in-circuit tests of semiconductor components, chips, PCB and other electronic peripherals.

Welcome to browse our website and download any catalogs of our products. If you need a complete set of product manual, please feel free to contact us. Many products are not uploaded due to a huge range. If you can't find what you need, please feel free to contact us.
�?� 
Notice:
Stock: standard product. As usual, they are in stock.
Express: DHL, FedEx, UPS, etc.
Payment: T/T, PayPal

Price and Minimum Quantity

Price: $0.1 - $50
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Harness Probe Pogo Pin Chz136-H(8.4)

GOLD Member
Nov-29-20
 
Warranty: 2 years
After-sale Service: Online technical support
Material: metal
Shelf Life:2 years
Instrument classification:Class II
Safety standard: none
Application: Cardiology
GOLD Member
May-16-21
Supplier From Saint-Paul, France
 
FINGERTIP PULSE OXIMETER

Parameters:

Two parameters:SPO2, Pulse Rate.



Waveforms:

SpO2 Waveform.



Features:

1 COLOR OLED display, four direction adjustable.

2 SpO2 and pulse monitoring, and Waveform display.

3 With menu operation.

4 With beep and alarm.

5 Low-power consumption, continuously work for 50 hours.

6 Small in size, light in weight, and convenient to carry.

7 Low voltage alarm display, Auto power-off.

8 Runs on standard AAA batteries.

Detailed descriptions of product functions:

SPO2:

1 Measurement range: 70%-99%

2 Accuracy: �±2% on the stage of 70%-99%, unspecified(<70%) for SPO2

3 Resolution: �±1%

4 Low perfusion: <0.4%

PR:

1 Measurement: range:30BPM-240BPM

2 Accuracy: �±1BPM or �±1%(the larger one)

3 Power: two AAA 1.5V alkaline batteries

4 Power consumption: below 30mA

5 Automatic power-off: the product shuts down automatically after no signal for 8 seconds
GOLD Member
Apr-04-21

Io2-Oximeter

$5.80 - $8.50
MOQ: 50000  Pieces
Sample Available
 
Pulse Oximeter is a non-invasive device intended for the spot-check of oxygen saturation of arterial hemoglobin (SpO2) and the pulse rate of adult and pediatric patients in home and hospital environments (including clinical use in internist/surgery, anesthesia, intensive care ect.). This device is not intended for continuous monitoring.

Major Features
1)value display
2)Pulse rate value display, bar graph display
3)Pulse waveform display
4)PI value display
5)The display mode can be changed
6)Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage
7)Pulse sound indication and over limit indication
GOLD Member
Jan-31-21
Supplier From Hyderabad, Telangana, India
GOLD Member
Aug-16-22
 
Elbow Joint Splint (AJY-S12)

It is used for elbow joint fixation for tendon, soft tissue, and nerve injury in the elbow joint in time for postoperative fixation of the joint.

448*260*3.2mm


LOW TEMPERATURE THERMOPLASTIC SHEET

Product features:
Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature.
It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability.

Scope of application:
1. Fixation after reduction of fractures and joint dislocations
2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries
3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor
metastasis or after debridement
4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed
5. Fixation after burns and other plastic surgery operations
6. Production and application of rehabilitation braces and orthoses
7. Posture placement and fixation during radiotherapy
GOLD Member
Aug-16-22
 
Achilles tendon dorsal splint (AJY-S11)

It is used for dorsal fixation after Achilles tendon injury, topological fixation of supporting foot.

442*247*3.2mm


LOW TEMPERATURE THERMOPLASTIC SHEET

Product features:
Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature.
It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability.

Scope of application:
1. Fixation after reduction of fractures and joint dislocations
2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries
3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor
metastasis or after debridement
4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed
5. Fixation after burns and other plastic surgery operations
6. Production and application of rehabilitation braces and orthoses
7. Posture placement and fixation during radiotherapy
GOLD Member
Aug-16-22
 
Thumb plate (tubular type) AJY-S03

For the first metacarpophalangeal joint, thumb phalanx, metacarpal fracture and wrist dislocation fixation.

210*145*3.2mm


LOW TEMPERATURE THERMOPLASTIC SHEET

Product features:
Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature.
It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability.

Scope of application:
1. Fixation after reduction of fractures and joint dislocations
2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries
3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor
metastasis or after debridement
4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed
5. Fixation after burns and other plastic surgery operations
6. Production and application of rehabilitation braces and orthoses
7. Posture placement and fixation during radiotherapy
GOLD Member
Aug-16-22
 
Hand function position fixed splint (AJY-S09)

It is used for the fixation of stable fractures of the hand and wrist, the fixation of neuromuscular and tendon injuries, and the fixation of functional positions after orthopaedic surgery.
Prevent deformity caused by bone and joint disease in thumb-to-finger and palm-to-hand positions shape.

337*170*3.2mm


LOW TEMPERATURE THERMOPLASTIC SHEET

Product features:
Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature.
It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability.

Scope of application:
1. Fixation after reduction of fractures and joint dislocations
2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries
3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor
metastasis or after debridement
4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed
5. Fixation after burns and other plastic surgery operations
6. Production and application of rehabilitation braces and orthoses
7. Posture placement and fixation during radiotherapy

Verification Status