Structure Size : 132-315
Rated Power : 2.2-160 kW
Pole Number : 4 - 6 - 8
Protection Class : IP55
Voltage : 380 V
Frequency : 50 Hz
Build Type : B3 - B5 - B3 / B5
Mechanical Structure : Body and covers are cast iron, legs are ductile iron
Cooling Type : IC 411
Insulation Class : A - E - B - F - H
Working Regime : S3- 100-60-40-25%
Ambient temperature : 40 C (Contact us for higher ambient temperatures.)
Motor Protection : Thermistor and motor protection relay for over 250 types (Applicable to smaller types.)
Cable Standard
According to DIN 72551-6 & ISO 6722 B
JIS C 3406, JASO D 611/608, IS 2465,
BS 6862 : PART 1
Cable Features
- Excellent flexibility
- The NESKEB Auto cables is impervious
to water, petrol, diesel, acids, engine and
lubricating oils and grease resistant
- High mechanical strength
- Excellent flame retardant properties
- Excellent mechanical & electrical properties
Standard Packing
Coils 100, 200, 500 and 1000m
Conductor
Flexible Bare Copper Wire
Insulation
Pvc Insulation
Cables Type
FLRY-A and FLRY-B
Color
Blue, Black, Brown, Grey, Orange,
Pink, Red, Violet, White, Green,
Yellow, Yellow / Green, Lining Strip
Color Also and as per Customer
Requirement
Temperature
20�?�°c to 105�?�°c
Application
These cables are used as original equipment's
for wiring automobiles and in the auto harnesses
BRAND : SCHNEIDER MCB
6A - 32A Single Pole Schneider Miniature Circuit Breaker.
Product Specification
No.of poles 1-4 Pole
Rated current 6 to 63 A
Voltage 240-415 V
Breaking Capacity 10 kA
Frequency 50 Hz
Curve Type B and C tripping curves
Brand Schneider
ABB MCB
System pro M compact S200M miniature circuit breakers are current limiting. Theyhave two different tripping mechanisms, the delayed thermal tripping mechanism foroverload protection and the electromechanic tripping mechanism for short circuitprotection. They are available in different characteristics (B,C,D,K,Z), configurations(1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 10 kA at 230/400 V AC) and ratedcurrents (up to 63A). All MCBs of the product range S200M comply with IEC/EN 60898-1 and IEC/EN 609 47-2, allowing the use for residential, commercial and industrialapplications. Bottom-fitting auxiliary contact can be mounted on S200M to save 50%
ALSTOM Reverse Power Relay CCUM 21 High Res
GBCCUM21PF113A
DEFINITE TIME REVERSE POWER RELAY
Technical specification CCUM21PF113A
Relay type CCUM21
CASE SIZE 1.5D S/E
CURRENT RATING 1 AMPS
V.T.SECONDARY 110V AC
FREQUENCY 50 HZ
TORQUE ANGLE(M.T.A) 30 DEG
OPERATING VOLTAGE 24V DC
CONTACTS 2M S/R
TIMING RANGE 2.5 TO 25 SECS
FLAG WITH FLAG
NAME PLATE RFH9072 604
NAME PLATE -1 RZF9151 601
OUTLINE DRAWING MFJ 013
WIRING DIAGRAM MPDZ609.01-1
GBCCUM21PF145J
DEFINITE TIME REVERSE POWER RELAY
Technical specification
Relay model no CCUM21PF145J
Relay type CCUM 21
Case size 1.5D S/E
V.T.Secondary voltage 110 V ac
Frequency 50 Hz
Current 1 amps
Torque angle(M.T.A) 30 Degree
Aux.voltage 110 V ac
Contacts 2 N/O S/R
Flag Yes
Timing range 2.5 to 25 Secs
Name plate VTT RZF9151 601
Name plate RFH9072 604
Outline drawing MFJ 013
Wiring diagram MPDZ 609 - 02-1
ALSTOM Reverse Power Relay CCUM 21 High Res
GBCCUM21PF103A
DEFINITE TIME REVERSE POWER RELAY
Technical Specifications
Model No : CCUM21PF103A
CCUM21
AUX. CURRENT OR VOLTAGE - 24V DC
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1-1/2D VERT. 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
MTA PHASE-CHAR ANGLE - 30 DEGREES
TIME DELAY P/U OR D/O - 2.5 - 25 SECS.
V.T/P.T SECONDARY - 110V AC
External Resistor
Name Plate RFH9072-604
RZF9151-601
Outline Diagram MFJ013
Wiring Diagram MPDZ609-01-1