Please click here to check who's online and chat with them.

Transformer On-Load Tap-Changer Tester

Supplier From China
May-15-21

The on-load tap changer is the only moving part connected with the transformer circuit so more and more attention has been paid to the detection of the on-load tap changer.In the electrical equipment handover and preventive test regulations it is required to check the action sequence of on-load tap changer measure switching time etc.This device is mainly used for measuring the transition waveform transition time transient resistance of transformer on-load tap changer three-phase synchronism etc.

product names On - load tap - changer tester transformer on - load tap - changer tester transformer on - load switch tester

Price and Minimum Quantity

Price: $770 - $15397
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Transformer On-Load Tap-Changer Tester

May-27-21

Transformer On-Load Tap-Changer

$770 - $15.40K
MOQ: Not Specified
 
The on-load tap changer is the only moving part connected with the transformer circuit so more and more attention has been paid to the detection of the on-load tap changer.In the electrical equipment handover and preventive test regulations it is required to check the action sequence of on-load tap changer measure switching time etc.This device is mainly used for measuring the transition waveform transition time transient resistance of transformer on-load tap changer three-phase synchronism etc.
May-11-18
 
GDKF Transformer Load and No Load Tester

Introduction:

It's used to Measure the transformer load and no load current, load and no load loss, short-circuit voltage, short circuit (load) losses and capacity.

Test items:

RMS phase voltage
Average value of three-phase AC voltage
Three-phase current RMS
Percentage of no-load loss and no-load current
Load loss, impedance voltage, and the percentage of short-circuit impedance
Any given temperature, load loss, the percentage impedance voltage and short circuit impedance
Voltage waveform in the percentage of each harmonic component
Current waveform in the percentage of each harmonic component

Technical index:
Current measurement range: 100mA ~ 5A, accuracy class 0.2;
Voltage Range: 10V ~ 650V, accuracy class 0.2;
External transformer can broaden the scope of measurement instruments;
Frequency Range: 40 ~ 65Hz, accuracy class 0.2;
Power Input: AC220V ± 10%

Company Information

Our company has become one of the leading manufacturer of petroleum testing instrument and electrical testing instrument since 2009sâ??.
We have developed sales channels in many countries such as Malaysia,India,Germany,USA,Mexico,Saudi Arabia,South Africa and other countries worldwide. and we have gained great advantage and high reputation in international market.
We are making effort to develop together with customers from both domestic and abroad on the basis of reciprocity.Client,quality and service are our supreme target.

Our Services

Pre-sale Service:
Inquiry will be replied within 24 hours.
Welcome to visit our factory.
Technical datas and operation manual sent for evaluation.
After-sale Service:
Training how to instal the machine, training how to use the machine at our factory;
Engineers available to service machinery overseas at customers' cost;GDKF Transformer Load And No Load Capacity Characteristic Tester
GOLD Member
Mar-01-24

Transformers

$20
MOQ: Not Specified
Supplier From Ludhiana, Punjab, India
 
Transformers,Distribution and Power Transformer,Varivolt
Safety Transformers
Diesel Generators
Industrial Panels
Stabilizers
Energy Saver
Industrial Panels
Dec-02-21

Current Transformer Field Tester

$770 - $15.40K
MOQ: Not Specified
 
Product description

Current transformer field tester was developed with high-end testing technology, large-scale electronic circuit design and accord with national related protocol . It has solved the problem of big working intensity,trival operation while on-site test of current transformer, voltage transformer. Meanwhile the product has a reliable performance,and the function is strong.



Technical index

Test range: 5A5A~25000A5A or 5A1A~5000A1A

Tested current transformer work scope: 1% 120%

Second load 2.5 VA 300VA, COS 0.8 1.0

Be tested current transformer accuracy range 1.0, 0.5, 0.5 S, 0.2 and 0.2 S

Resistance, admittance measurement errors 5.0%

Measurement range R 0.00 ~20.0 Y 0.000mS~100.0 mS

Power consumption 20 VA

Accuracy level 0.05 S level

Shape dimension mm 460 L 375 W 183H

Weight kg 10



Feature

HCCT-H Current Transformer Field Tester with recursive method to measure current transformer error, as well as potential difference method to measure voltage transformer error function, convenient for carrying out calibration work of field metering device.

HCCT-H Current Transformer Field Tester without using Standard Current Transformer, Current Source, Load Box, Double Adjustable Control Box and Primary cable, using extremely simple test connection and operation to realize the current transformer test, greatly reduce work intensity and improve the work efficiency, convenient to carry out current transformer field test work.
GOLD Member
VERIFIED
Jan-27-24
Supplier From Ahmedabad, Gujarat, India
GOLD Member
VERIFIED
Jul-12-24
Supplier From Mumbai, Maharashtra, India
Aug-26-22
 
Product description

The current booster is used on checking current transformer,to be the power source supply once current for current transformer or to be other 50Hz single phase current source device.



Technical index

Temperature

Humidit

Capacity: 20kVA

Specification

Weight: 75Kg

Allow long-term work on the rated current

Allowable overload 1.5 times,30 minutes of continuous work.



Feature

This PSLLQ is make up of input Winding(220V), output winding below 100A and CXRZ.

Output current indicated on the nameplate is defined the rated current that through winding allow to pass.When CX many circles, the rated current its permitted to pass through will inversely decline.

The value which ouput capcity divided by product of output current and each circle voltage was the biggest circle number allowing.



The current booster is designed to provide the primary current power supply for the current transformer when verifying the current transformer or as other 50HZ single-phase power equipment. The current booster for transformer verification is suitable for power departments such as power testing, power measurement, and power maintenance. The current booster is developed and produced according to the industry standard of transformer error testing, and is used as a current transformer to verify the primary current of the current transformer. The output current can be customized according to customer requirements. The lifter is equipped with casters for easy on-site movement.
Jul-01-21

Transformer On-Load

$770 - $15.40K
MOQ: Not Specified
 
The on-load tap changer is the only moving part connected with the transformer circuit so more and more attention has been paid to the detection of the on-load tap changer.In the electrical equipment handover and preventive test regulations it is required to check the action sequence of on-load tap changer measure switching time etc.This device is mainly used for measuring the transition waveform transition time transient resistance of transformer on-load tap changer three-phase synchronism etc.
May-29-21

Transformer Capacity Load No-Load

$770 - $15.40K
MOQ: Not Specified
 
Product Introduction
This product is specially used for measuring the capacity of distribution power transformer measuring the no-load and short-circuit loss of transformer and has the function of harmonic analysis which is convenient for analyzing the quality of on-site power network. The device can automatically check whether the wiring is correct and display the vector diagram of the three-phase current and voltage when testing the three-phase transformer. At the same time necessary correction (such as waveform correction temperature correction unrated voltage correction calibration unrated current correction) is introduced to make the test results more accurate.

Product name Transformer capacity test instrument transformer capacity load tester

Verification Status