Please click here to check who's online and chat with them.

Hg Calibration Lamp

Supplier From India
Apr-26-25

Hg Calibration Lamp

Useful for E/M by Zeeman effect

Price and Minimum Quantity

Price: Negotiable
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Hg Calibration Lamp

GOLD Member
Apr-26-25
 
Hydrogen Lamp

With power supply 410.2, 434, 486.1, 656.3mm Calibrated lines.
GOLD Member
Apr-18-25
 
SALIENT FEATURES:

1. Full wavelength scanning (190-1100nm) covers UV, Vis. near IR.


2. Fully sealed structure, all optical mirrors are equipped with SiO2 protective film to avoid stray light caused by dust and corrosive gas.


3. Core components reduce the stray light and improve the stability and reliability.


4. Double beam optical system with precision vertical-type dual optical path and dual detector.


5. Grating of high performance greatly reduces the stray light and improves the stability and reliability of device.� 


6. 10 inches large touch screen, built-in 32GB memory.


7. Powerful data analysis system with internal computer could realize multi functions independently. Like establishing calibration curve, photometric measurement, quantitative measurement, spectral scanning, dynamics, DNA/Protein test, multi-wavelength analysis and data printing.


8.� � W Lamp / D2 Lamp can monitor of usage hours.


9. Data can export in Pendrive directly


10. Convenient data storage and printing function. LUV Series can be directly connected to the printer HP DESKJET 2723 for A4 paper data and graph printing.


11. Automatic power ON self test and system positioning function could inspect and calibrate the deviation before every use.� 


12. All test data and analysis report can be exported to USB disk directly.


13. Graphs support 3D display,


14. PC software follows GLP & GMP standards, user management, logging, data tracking, etc. mostly as per 21CFR Part 11.



 

Specifications:



MODEL
LUV2000T� � � � � � � � � � � � � � � LUV2100T


Bandwidth
1.0nm� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 1.0, 2.0, 4.0,5.0 nm (variable)


Make
LABMAN


Optical System
Double beam


Wavelength Range
190-1100nm


Wavelength Accuracy
� � � � � � � � � � � � � � � � � � � � � � � � � � � � � +0.1nm(D2 656.1nm),+0.3 nm full range


Wavelength Repeatability
+0.1nm


Photometric Range
� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 0-200%T. -0.3-3.0A, 0-9999C


Photometric Accuracy
+0.2T(0-100%T), +0.002Abs(0-0.5Abs),+0.004Abs(0.5-1.0Abs )


Photometric Repeatability
<0.05%6T(0-100%6T), 0.001Abs(0-0.5Abs), 0.002Abs(0.5-1.0Abs)


Stability
+0.0004A/h @ 500nm


Stray Light
0.03%T @ 220 nm, 360 nm


Cell Holder
10mm each, Sample & Reference Cuvette Holder


Focal Length
10mm


Light Source
Tungsten Lamp & Deuterium lamp


Resolution
0.1nm


Display
Touchscreen 10-inches (800 x 480) HD TFT


Memory
32GB


Detector
Silicon Photodiode


Control Mode
Stand-alone system/PC software


Baseline flatness
+0.0008A/h


Data Output
USB


Power Supply
Adaptor, Using AC 220V,50/60Hz


Dimension (L x W x H
VERIFIED
Jun-16-21
 
Box dimension - 1000mm x 750mm x 750mm
Box Material - Stainless steel 304 L box with mirror finish inside brushed finished outside
Acid resistant
Box panel/window Openable Front window with polycarbonate an extra coating for chemical and scratch resistance One

Feed through electrical single phase 220 V - 16 A
Attainable purity < 100ppm H2O and < 500ppm O2 at complete pressure range.
O2 = 20 l , H2O = 960 g
Filtration HEPA : particles
Glove Ports - Glove ports, 220mm diameter and should be O ring sealed
Gloves Materials
Gloves Piercan USA make Neoprene, or Butyl
Dust filter - 0.3 micron Dust filter. HEPA Filter
0.3 micron HEPA, H13 or H14
Gas Purifier - Molecular sieves, Activated Carbon, Charcoal chamber with high efficient O2 ,H2O adsorbent One each

Shelves - Height Adjustable, Acrylic Stainless Steel shelves
Three/ Yes
Box Pressure Control -+15 mbar to -15mbar. Automatic pressure control. Yes
Box Lamp -One front mounted fluorescent lamp one inside
Yes
Antechamber Type Cylindrical, 300 mm diameter, Length 600mm (inside dimensions) Material stainless steel, thickness 2.5mm Inside surface brushed finish Sliding tray stainless steel Doors SS thickness 10mm Door lock easy to operate, spindle lock Pressure gauge, monometer: analog display Vacuum/ Refill process.

Regeneration Below 5% loss Complete automated or manual operation with foot switch Yes
Sensors Solid state oxygen sensor with 0- 1000 ppm & Solid state moisture sensor with 0-500 ppm Auto purge PLC controlled via system control panel.
PLC Program Logi Control with integrated control with external display unit 10 One Yes
Vacuum Pump 740 mm HG with fittings (Optional) High Vacuum Pump: Oil sealed vacuum pump â?? 150 lpm,Vacuum level : 5x10ï?­2mbar
Type rotary vane pump, dual stage, Oil mist filter, Oil recirculation, Automatic gas ballast control, 10 m3/h Optional facility for automatically turning off the vacuum pump when the antechamber is not in use
One
Recirculation Pump Optional Re circulating purified gases pro rata basis 20m3/
per hour
Service Support - Efficient service facilities with trained engineers at your place
warranty
One years comprehensive onsite warranty.
VERIFIED
Jun-16-21
 
Box dimension 1000mm x 750mm x 750mm
Box Material Stainless steel 304 L box with mirror finish inside brushed finished outside
Acid resistant
Box panel/window Openable Front window with polycarbonate an extra coating for chemical and scratch resistance One

Feed through electrical single phase 220 V - 16 A
Attainable purity < 100ppm H2O and < 500ppm O2 at complete pressure range.
O2 = 20 l , H2O = 960 g Yes
Filtration HEPA : particles Yes
Glove Ports Glove ports, 220mm diameter and should be O ring sealed
Gloves Materials Gloves Piercan USA make Neoprene, or Butyl
Dust filter 0.3 micron Dust filter.HEPA Filter 0.3 micron HEPA, H13 or H14
Gas Purifier Molecular sieves, Activated Carbon, Charcoal chamber with high efficient O2 ,H2O adsorbent
Shelves Height Adjustable, Acrylic Stainless Steel shelves
Box Pressure Control +15 mbar to -15mbar. Automatic pressure control.
Box Lamp One front mounted fluorescent lamp one inside
Antechamber Type Cylindrical, 300 mm diameter, Length 600mm (inside dimensions) Material stainless steel, thickness 2.5mm Inside surface brushed finish Sliding tray stainless steel Doors SS thickness 10mm Door lock easy to operate, spindle lock Pressure gauge, monometer: analog display Vacuum/ Refill process.
Regeneration Below 5% loss Complete automated or manual operation with foot switch Yes
Sensors Solid state oxygen sensor with 0- 1000 ppm & Solid state moisture sensor with 0-500 ppm Auto purge PLC controlled via system control panel. Yes One Each
PLC Program Logi Control with integrated control with external display unit 10â?? One Yes
Vacuum Pump 740 mm HG with fittings (Optional) High Vacuum Pump: Oil sealed vacuum pump â?? 150 lpm,Vacuum level : 5x10 2mbar Type rotary vane pump, dual stage, Oil mist filter, Oil recirculation, Automatic gas ballast control, 10 m3/h Optional facility for automatically turning off the vacuum pump when the antechamber is not in use One
2Recirculation Pump Optional Re circulating purified gases pro rata basis 20m3/
per hour
Service Support Efficient service facilities with trained engineers at your place
warranty One years comprehensive onsite warranty.
Jan-15-09
 
Main specifications:
1. Test speed: 300 tests/hour
2. Assay types: end-point assay, rate assay, fixed-point assay
3. Cuvette: 120 reaction bottles; optical length:6mm
4. Sample tray: 60 non-fixed positions for various samples
5. Reagent tray: 45 positions for reagent bottles
6. Assay items: 45 items once time
7. Cuvette: 120 reaction bottles; light path length: 6mm
8. Compatible reagent: supports different reagents from different countries
9. Total reaction volume: 180ul minimum
10. Sample volume: 2 to 50 micro liters
11. Reagent volume: r1 25ul-300ul; r2 10ul-150ul
12. Reaction time: about 10 minutes
13. Wavelength: 340, 405, 510, 546, 578, 630, 660, 700nm
14. Quality control: 6 types per test item
15. Calibration methods: linear and non-linear
16. Wavelength: 340, 405, 510, 546, 578, 600, 660, 700...
17. System function: 24 hour non-stop working,
Support stat tests; 2-wavelength photometer
18. Lamp: 12v35w, 8 photodiodes.

Verification Status