Bio safety Cabinet Class II Type A 2,Recirculates 70% of HEPA filtered air and rest 30% air exhausted through optional exhaust system. Fitted with Microprocessor LCD display controller with facility to display air velocity across work table.
Features
30% air exhaust
70% air recirculation
HEPA OR ULPA -filtered exhaust air in Type A2 cabinet may be recirculated into the room or exhausted to the outdoors through a canopy exhaust connection.
HEPA OR ULPA -filtered downflow air is a portion of mixed downflow and inflow air from a common plenum.
Negative Pressure air surrounding all biological contaminated ducts and plenums.
Negative pressure surrounds the work area with double wall plenums for protection.
Air drawn through pre-filter is made to pass through highly effective HEPA OR ULPA (High Efficiency Particular Air) filters. The prefilter fitted extends the life of HEPA OR ULPA filter drastically. Fitted with HEPA OR ULPA Filter made from water resistant, fire retardant, imported micro fine glass fibre media; conforms to EU â?? 14 Grade, with an efficiency rating better than 99.999% for 0.3 �¼.These filters are designed to accommodate higher air flow volume.
Prefilter are made from Non-Woven Synthetic with HDPE mesh and Al expanded mesh on air leaving side; conforms to EU â?? 4 / G-4 Grade, with an efficiency of down to 10 micron. These filters can be cleaned by compressed air & also washable.
Mounted on heavy tubular stand with lockable castors.
Aerodynamic airflow grills maintain safety and prevent blockage
U.V and fluorescent interlock available
Ergonomic and comfortable 10 degrees sloped front window for comfortable head and elbow rest position, thus reducing fatigue.
The sash is counterbalanced for smooth and lightweight operation with the standard opening of 200mm �±10 mm for easier access to work zone and enhanced user safety.
Class II Biosafety Cabinet Protection
High velocity air forced through HEPA OR ULPA filters.
Filtered air is thrown in the chamber through jet nozzles with a high velocity which in turn disperse particulate matter on all surface.
The lower portion of the Air showers suck the contaminated air and allow it to pass to blower supply plenum through pre-filter installed at the base.
This process is a continuous process in which air is continuously filtered and recirculated inside the chamber without any exchange with the external environment.
Upper & front cover
Removable upper and front cover simplifies filter, blower and front control panel replacements and maintenance easier.
Material of construction
Working Table is made up of Stainless Steel (SS-304). External Cabinet is fabricated of CRC sheet duly powder coated
Front Window/Sash
Front Sash consists of a toughened transparent glass for a clear inside view. In addition it serves optimum resistance and protection from harmful UV rays, protects user from exposure to har
Supplier: Tempered glass, laminated glass, mirror, acid etched glass, fritted glass, float glass, reflective glass, low e glass, patterned glass, glass bottle, glass jar, glassware, glass tube, glass cup