Attribute: Rated input voltage 10mV, 50mV, 75mV, 5V, 50V, 75V, 150V, 200V, 300V, 400V, 500V, 750V, 1000V DC Output signals 0-20mA, 4-20mA DC Accuracy 0.2% Input Impedance (R) approximate zero Responding Time 350ms Linear measuring range 0 - 1.2 times of rated input current
Attribute: Rated input voltage 10mV, 50mV, 75mV, 5V, 50V, 75V, 150V, 200V, 300V, 400V, 500V, 750V, 1000V AC Output signals 0-5V ,0-10V DC Accuracy 0.2% Responding Time 200ms Linear measuring range 0 - 1.2 times of rated input current Over Load Capacity 10mA Static current 6mA Power supply DC 12V, 24V
Function & Feature 1. Isolate the DC voltage input signal from the DC Output signal, which is directly proportional to the input signal. 2. These isolators can be used to prevent earth loops, which occur when a measuring source 3. Excellent temperature characteristic and good working stability. 4. It have an advantage over loop powered units, in that if for any reason the output lead should become disconnected, the input will not be saturated. 5. Fixed in a standard 35mm DIN rail or screwed on the cabinet.
Function & Feature 1. Have microcontroller technology as the core, using the latest algorithms, to achieve precise measurement. 2. Voltage transducer converts an ac voltage input into a load independent output signal. 3. Excellent temperature characteristic and good working stability. 4. The output signal is based on the a root mean square(rms) measurement of the input signal and hence the transducer can be used with distorted waveforms. 5. The unit conforms to IEC 60688. In a addition it meets the insulation requirements of IEC 60255-5, clauses 5, 6 and 8 as well as the high frequency disturbance test of IEC 60255-22 for Class III test voltage.
Function & Feature 1. Isolate the DC voltage input signal from the DC Output signal, which is directly proportional to the input signal. 2. These isolators can be used to prevent earth loops, which occur when a measuring source 3. Excellent temperature characteristic and good working stability. 4. It have an advantage over loop powered units, in that if for any reason the output lead should become disconnected, the input will not be saturated. 5. Fixed in a standard 35mm DIN rail or screwed on the cabinet. Specifications Inputs: System input 0~5V, 0~30V, 0~60V, 0~300V, 0~400V Absorbed power 0.1VA Output: Standard nominal outputs 4~20mA, 0-5V, (others on request) 0-20mA, 5-10V 0-10V Respones time
Function & Feature 1. Have microcontroller technology as the core, using the latest algorithms, to achieve precise measurement. 2. Voltage transducer converts an ac voltage input into a load independent output signal. 3. Excellent temperature characteristic and good working stability. 4. The output signal is based on the a root mean square(rms) measurement of the input signal and hence the transducer can be used with distorted waveforms. 5. The unit conforms to IEC 60688. In a addition it meets the insulation requirements of IEC 60255-5, clauses 5, 6 and 8 as well as the high frequency disturbance test of IEC 60255-22 for Class III test voltage. Specifications Inputs: System voltages 100V,220V, 380V, 450V Absorbed power 0.5VA Frequency range 50Hz, 60Hz Output: Standard nominal outputs 4~20mA, 0-5V, (others on request) 0-20mA, 5-10V 0-10V Ripple
This is a DC voltage and current transducer. The operating principle is Photoelectric Isolation/Treble isolation. It can measure DC voltage and DC current at the same time, and has two channels of standard signal. The input, output and power supply are isolated from each other. It's featured in high accuracy, high isolation, low drift and so on. This product can be used in railway, industry control, and other fields. Rated input: 0~1-500V; 0~0.5-5A Output signal: 0~5V DC (Vz); 0~20mA (Iz); 4~20mA (Iy);0~10V DC (Vd);OC frequency output:(0-5KHz/0-10KHz) optional Power supply: 12V;15V; 24V; optional Accuracy: 0.5% optional Output ripple: 10mV Isolation: 2500V DC Humidity: â?¤95%(no dew) Load resistance: Voltage Output >2kohm; Current Outputâ?¤250ohm Temperature drift: 500/ppm Response time: â?¤200ms Operating temperature:: -10~+60 Quiescent power consumptio:
The one element DC multi-parameter digital transducer is used for measuring DC current, voltage and power parameters.Its inputs are DC current (output of mating transducer) and DC voltage, and its outputs are digital data of the DC current, voltage and power through RS-485 interface. It can be applied to various measuring and controlling systems such as communication, power grid and electrization railway etc. Parameters Part numbers: CE-AD11-34MS3-0.5/0~500V 0~5A Description:Input: 0-500VDC,0-5ADC,Output interface: RS-485.MODBUS protocol,Power supply:24VDC(21~27V),Accuracy:0.5%,Window:none,Case style:S3 Part numbers: CE-AD11B-37MS5-0.5/0~1000V 0~5A Description:Input: 0-1000VDC,0-5ADC,Output interface: RS-485.MODBUS protocol,Power supply:+9~55V,Accuracy:0.5%,Window:none,Case style:S5 Specifications Voltage input: 0~25mA~500V DC (MS3) 0~25mA~1000V DC (MS5) Current input: 0~10mA~5A DC (Output of mating Hall Effect analog current transducer) Output data: DC Voltage, DC Current, DC Power (product of the voltage and current) Accuracy: 0.2% Baud rate: 1200, 2400, 4800, 9600 and 19.2K bps Refresh period: 100 mS Input overload: 2 times of full span (1 second, 10 times) Power supply: +24VDC(MS3) +9~55V(MS5) Static power consumption: £500 mW Operating temperature: 0~50°C Storage temperature: -55~+85°C Isolation voltage: >2500V DC Application: Digital data acquisition Automation system integrator Electrical distribution system Industrial automation engineering Process automation system
Function & Feature 1. Isolate the DC voltage input signal from the DC Output signal, which is directly proportional to the input signal. 2. These isolators can be used to prevent earth loops, which occur when a measuring source 3. Excellent temperature characteristic and good working stability. 4. It have an advantage over loop powered units, in that if for any reason the output lead should become disconnected, the input will not be saturated. 5. Fixed in a standard 35mm DIN rail or screwed on the cabinet. 6. Ultra-thin dimension, suitable for limited space, the control cabinet.
Function & Feature 1. Isolate the DC voltage input signal from the DC Output signal, which is directly proportional to the input signal. 2. These isolators can be used to prevent earth loops, which occur when a measuring source 3. Excellent temperature characteristic and good working stability. 4. It have an advantage over loop powered units, in that if for any reason the output lead should become disconnected, the input will not be saturated. 5. Fixed in a standard 35mm DIN rail or screwed on the cabinet. 6. Ultra-thin dimension, suitable for limited space, the control cabinet. Specifications Inputs: System input 0~5V, 0~30V, 0~60V, 0~300V, 0~400V Absorbed power 0.1VA Output: Standard nominal outputs 4~20mA, 0-5V, (others on request) 0-20mA, 5-10V 0-10V Respones time
Current transducer, voltage transducer, power transducer, frequency transducer, offside alarm transducer, insulator, current sensor, voltage sensor..
Type includes:Silicon Piezoresistive Pressure Sensor,Capsule Pressure Transducer,Pt, Ps Transducer,Pt, Ps Transducer,Intelligent Transducer,Wireless pressure sensor Performance: Silicon Piezoresistive Pressure Sensor: Measurement Range: 0~36MPa; Tolerance:±3‰; Temperature Range:?55~?230? Different structure single or multi sensors can be applied to measure pressure of different gas or liquid; Output voltage signal or power current signal or digital signal;Size can reach F19mm Capsule Pressure Transducer Mainly used on the engines, measuring Pv, Ps, Pt, altitude etc. Pressure range: 0~36MPa, accuracy: ±1.5%; Temperature range: ?55~?220?; Major types: inductor, differential transformer, potentiometer etc. Pt, Ps Transducer Flow speed is held to be zero in the Pt cavity at the pitot front end. Therefore, the pressure measured is Pt. Ps can be measured by the side orifices. Pt-Ps=Pd. Altitude Transducer Measuring flight altitude, transforming the absolute pressure to a voltage output Intelligent Transducer? Sensing Pt & Ps, receiving resistance single of the temperature, and AOA voltage single from AOA Transducer. After error correction, it calculates the flight air data per the air data equation and supplies the results to other systems. Altitude & Velocity Transducer Used on aircrafts, measuring altitude, velocity and acceleration. Input is Pt, Ps, Pd and output is DC voltage, in proprtion with input signals. Ps is a dual-channel independent signal. Acceleration DC voltage signal in X, Y, Z axes and temperature signal are available. AWP Wireless pressure sensor Characters: 1.Low power consumption, long standby time 2.wide pressure measurement range10kPa~10MPa 3.Adjustable sampling rate(10min~12h) 4.Zigbee wireless communication protocol 5.long distance transmission 6.Full Metal Package with the IP65/67 Protection class 7.Good appearance
For the Mosquito killer Led Bulb Light, is a 900 lumen bulb that doubles as an insect killer. The light features a blue UV LED which attracts insects into a Mosquito Killer grid.And the Mosquito Killer grid uses only 1W of electricity, while the light itself uses a meager 9W – and both can be used independently.They are used at home and outdoor. A brush is provided to clean off insects once the bulb switched-off.Compare to other traditional mosquito killer, this bulb has no chemicals, no sprays and hence no fumes to our life. 2nd generation 2-in-1 LED LIGHT Bulb Plus LED Mosquito Killer Bulb Wattage: 10W Blue UV light Lumen: 900-1000lm Color Temperature (CCT): 6500K Input Voltage: AC 90-130V & 220v-240V With CE and ROHS Operation: Step1: Switch it on,both lighting +killing are on. Step2: Switch on again,light off,only killing on. Step3: Switch on again,killing off,only light on. Step4: Switch off, both off.
Ultrasonic Transducers Name Method Eg, UCE-6845D-20LA PZT8 UCE mean our company logol. 68 is stand for the dimetions of radiation head, 45 is stand for the dimetions of the piezoelectric ceramic,PZT8 is mean the material of piezoelectric ceramic,PZT8 is yellow ceramic,PZT4 is black. Ultrasonic Transducers is one of main products of at UCE ultrasonic,which used the piezoelectric effort to realize transduction between electric and sound energy,also named as BLT transducer,ultrasonic transducer normally used in ultrasonic cleaning industry,high power ultrasonic etc.
Electropneumatic transducer Input electrical current:4-20ma, 0-10v Output pressure:20-100kpa Et-500 is electropneumatic transducer equipment, it can decrease supply pressure to produce output pressre which is effectively proportional to input electric signal. Supply pressure range:125kpaí½1000kpa.With bulk augmenter supply big flow (20.4 m3/h). Features: Flow rate: 7.6m3/h when supply pressure is 175kpa 20.0m3/h when supply pressure is 700kpa Min/max. Supply pressure: Minimum-3psig(21kpa) above maximum output Maximum-100psig(700kpa) Sensitivity:
PTC thermistors, winding protection relays, voltage & current relays, transducers, alarm annunciators, voltage current power transducers, digital multi function meters.
"FAMAGA Group OHG, the global supplier of industrial equipment and spare parts, is glad to provide encoders by Transducers SENECA: We supply a complete range of the manufacturerâ??s catalog, including the following items: SENECA T201 SENECA Z109REG2 SENECA Z-SG SENECA �¢201 SENECA T201DC SENECA T201DCH100 SENECA K121 SENECA 1K-RS65-03 SENECA T201DCH300-LP SENECA T201DCH300 SENECA T201DCH100-LP SENECA Z-SG-L SENECA Z-10-D-IN SENECA Z170REG-1 SENECA S105TCS-3 SENECA Z-PC-DINAL2 SENECA Z-PC-DINAL2-17.5 Our company is also pleased to offer products of other brands: Bei Sensors IBH Softec Schmersal BALLUFF Pepperl+Fuchs Bernstein Di-Soric Elobau Univer Eltra Aventics FESTO Camozzi Euchner END-Armaturen TAMAGAWA SENECA Airtac Murrelektronik Azbil Yamatake FRANKE-Filter Endress+Hauser IFM Ipf Electronic Kieback & Peter MD Micro Detectors Bihl Wiedemann ANDERSON-NEGELE KITAGAWA Georg Schlegel Metal Work Kipp Allen-Bradley Netter Vibration Kuebler / K�¼bler RAFI LINDY 4B Braime SOUTHCO ELGO Electronic FAG RECO Pilz AIRTEC Pneumatic COMITRONIC-BTI L�¼tze Hydac Barksdale Keyence AirCom Pneumatic Garlock Mac Valves MAHLE (Filtration Group) Riegler Baumer Elreha Sick Siko FAMAGA Group OHG is a family-owned company with many years of experience in the supply of components and spare parts for industrial enterprises around the world. Our mission is to provide fair prices, reducing the cost of production for our customers. A significant network of suppliers around the world allows us to supply any equipment, which client needs on favorable terms. Therefore, the list of equipment we provide is tenfold greater than the catalog presented on this site. You are welcome to check the full catalog on our website."