Sterile infusion set for single use
Model: infusion set: GB8368 IS-V
infusion set: GB8368 IS-NV
Product structure: plastic protector for spike, spike, air-inlet, soft tube, drip chamber, flow regulator, fluid filter, and injection site for adding fluid drugâ?¦etc.
Product instruction: The products are made by medical polymer materials. Sterilized by EO gas; sterile, non-toxic, pyrogen free. The products are made by medical soft materials surface is sound and transparent.
Technical indication: in accordance with GB8368 and ISO8536-4.
Scope for use: The products are used for intravenous gravity infusion.
Automatic calibration
Audible and visible alarms
Three working mode: rate/time/volume
With ultrasonic sensor for drop-counting
Lcd, night operable
English or other language display
Specifications
Drop detector: outside caliper rotary detector. (patented technology)
Control way:
Drop counting and adjusting the delivery rate automatically
Pump type: peristaltic finger
Applicable iv sets:
Compatible with iv sets of any standard (including lucifugal iv sets)
Accuracy:
ín25drop/min: ía2%,
>25drop/min: ía3% (with the drop counting control mode)
ía5% (with the rate control mode after the correct calibration)
Delivery rate range:
1í½400drop/min(1drop/min step)
1.0ml/hí½1200ml/h (1.0ml/hí½99.9ml/h, 0.1ml/h step; >99.9ml/h, 1ml/h step)
Delivery time range: 1miní½1999min (1 min step)
Volume limit range: 0í½9999ml (1 ml step)
Total volume range: 1í½9999ml (1 ml step)
Rapid injection: 600ml/h
Bolus: bolus rate 10-1200ml/hr, bolus volume: max of 100ml
Kvo rate:
When the delivery rate ín10ml/h, kvo is 1ml/h. Otherwise kvo is 3ml/h.
Alarms:
Air-in-line, infusion complete when limited volume has been set, empty container, occlusion, door is open, waiting time over, no drop been detected, operational errors, low battery, other device failures.
Power supply:
Ac power supply: ac 100 to 240vía10%ú¼50/60hzú+
Internal li battery: 11.1v, 2000mah. 6 hours of continuous operation on a new fully charged battery with the rate of 20 drops/min.
Power consumption: ín25va
Safety level: classó±, type cf
Operating conditions: ambient temperature: 5 to 40íµíírelative humidity: 20 to 90%
Storage conditions: ambient temperature: -10 to 55íµíírelative humidity: 10 to 90%
Accessories: ac power line, operational manual
Dimensions: 130mm(l)íß 200mm(w) íß 230mm(h)
Net weight: approximately. 2.0kg
3.5 inch LCD screen for clear vision within 5 meters
Different types of indicator
One-button night mode design for patientâ??s more comfortable rest at night
User friendly numeric setting key
Pull & Push hook design for easier door open and close
Anti-slip pump base support
Finger-tip peristaltic pump with down-stream free-flow protect
Infusion
Blood Transfusion Sets
Blood Donor Sets
Disposable Syringe
Insuline Syringe
IV Cannula
Safety IV Cannula
IV Cannula Fixator
Scalp Vein Set
Measured Volume Burette Set
Extension Tube
IV Flow Regulator
Three Way Stopcock
Three Way Stopcock With Extension Tube
Pressure Monitoring Line
Luen Lock
Injection Stopper
CVP Manometer
Strong airvent spike with bacteria barrier at inlet, flexible drip chamber, disc filter in drip chamber,kink resistant tubing, strong roller clamp, latex bulb or y-site. Luer slip or male rotator.
The cyject brand represents high quality, as all products are manufactured under strict quality guidelines to conform to the highest of international standards. Our international sales office operates from south africa, and exports are coordinated professionally, to supply goods direct from our factories in china, turkey & india.
Should you require samples, we would be pleased to send you samples of our products.
Features for FA3 Series:
Can display and preset the speed rate and volume
Can display the infused volume
Speed rate unit: ml/h
With Bolus rate(Purge rate) function
Occlusion alarm pressure is selectable
Automaticlly recognize the syringe type - 10ml,20ml,30ml,50/60ml
Possess temporarily clear up alarm function and recover set time alarm function
Whenever speed rate more than 0.1ml/h,after the preset volume alarms, it turns to KVO speed rate automaticly.
Display the accumulative infused volume
Clear up the accumulative infused volume
Internal battery embedded.
Specifications
Controls:
Drop counting and adjusting the delivery rate automatically
Pump type: peristaltic finger
Applicable iv sets:
Various iv sets(including lucifugal iv sets)
Accuracy:
25drop/min:2%, >25drop/min:3% (used in the drop counting control way)
5% (used in the volumetric control way with the correct calibration)
Delivery rate range:
1½400drop/min(1drop/min step)
1.0ml/h½1200ml/h (1.0ml/h½99.9ml/h, 0.1ml/h step; >99.9ml/h, 1ml/h step)
Delivery time range: 1min½1999min (1 min step)
Volume limit range: 0½9999ml (1 ml step)
Total volume range: 1½9999ml (1 ml step)
Purge rate: 600ml/h
Kvo rate:
When the delivery rate 10ml/h, kvo is 1ml/h. Otherwise kvo is 3ml/h.
Alarms:
Air-in-line, infusion complete(a volume limit has been set), empty container, occlusion, door open, over time, no drop sensor, operation error, low battery and other device failures.
Power source:
Ac power supply: ac 100 to 240v10%ú¼50/60hzú+
Internal li battery: 11.5v, 2000mah. Battery life with continuous operation is approx. 8 hours (when using a new, full charged battery and running at 20drop/min with any standard of iv set).
Power consumption: 25va
Shock protection: classó, type bf
Generic name Three-layer co-extrusion infusion film
Standard YBB00102005-2015 Q/321281GSB67-2020 EP(3.1.6) USP USP
Specification 200 m(thickness)*500m(length)
Features The main polypropylene material is blended and modified with styrene elastomers and polyolefin materials, suitable for packaging various formulations