Please click here to check who's online and chat with them.

Find Verified Residual Current Circuit Breaker (Id Rcd ) Suppliers, Manufacturers and Wholesalers

Jun-21-24
 
Specifications ID Residual Current Circuit Breaker
Rating up to 100 A
Breaking capacity up to 6 k A
Model No: ID
Rated Current: 16, 25, 40, 63, 80, 100 A
Sensitivity : 10, 30, 100, 300, 500 m A
Rated Voltage: 230 VAC(2 P), 400 VAC(4 P)
No. Of Pole: 2 P, 4 P
Type: Type AC and Type A
Breaking Capacity: 6000 A
GOLD Member
Jun-17-25

Eaton Kd3350 Series 3 Industrial Circuit Breaker, NEW

$1.44K - $1.56K / Box (FOB)
MOQ: 1  Boxes
Supplier From Doral, United States
 
brand new Eaton KD3350 Series 3 Industrial Circuit Breaker with 3 poles and a rating of 350A at 600V. It is a premium quality product from a reputable brand and is designed for use in industrial automation and motion control applications. The breaker is compatible with the Automate controller platform and is perfect for use in PLC processors
Jan-30-11
Supplier From Lauf-A-D-Pegnitz, Germany
 
It can happen very quickly: Thoughtlessly touching a currentcarrying cable; a faulty connecting cable; or a device fault. Happy are those who have protected their electrical system with the right RCCB. In the event of damage, it is activated within a fraction of a second, breaks the circuit and thus possibly saves lives. In this way, everyday exposure to current gets considerably safer.

For new installations and extensive renovations of commercial and private electrical systems, the use of RCCBs is mandatory according to VDE 0100-410 since June 2007 anyway. This also refers to all outdoor electrical systems and electric circuits.

Our product range offers you the right RCCB solution for every field of application because - in addition to devices of type A (sensitive to pulsating currents) and type B (sensitive to universal current) for the German market - we can also deliver devices of type AC (sensitive to alternating current - not approved for Germany) for export.
Sep-30-20
Supplier From Delhi, New Delhi, India
 
Brands : Schnieder, Abb, Legrand, L&T, C&S, Chint, HPL, Hager, Havells, etc
Current Rating : 6A to 125A
No Of Poles : 2P, 4P
Voltage Rating : 230 - 240 VAC, 230 VAC, 240 - 415 VAC, 400 - 415 VAC , 415 V
Breaking Capacity : 6KA to 10KA
Sensitivity (mA) : 30 mA to 500mA
Buy RCCB online from India at wholesale rates. If you have been looking for Schneider, ABB, L&T, Siemens, Chint, havells, HPL, Hager etc RCCB dealers, your search ends here as you can get the best RCCB distributors in countries such as USA, UK, Australia, Sweden, Africa, Middleeast, Europe, Asia etc. You can purchase RCCB of the finest quality and rest assured to get the best in terms of both durability and performance. If you are bothered about the prices, you can be totally sure to get the best rates as brings you genuine Products.
May-23-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A (can be extended to 125A)
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current : A/AC
5331 Residual Current Circuit Breaker (Id Rcd ) Suppliers
Short on time? Let Residual Current Circuit Breaker (Id Rcd ) sellers contact you.
May-23-19
 
Standard: IEC/EN61008-1 GB/T16916.1
Release Type of Leakage Protection: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current: A/AC
May-23-19
 
Standard: IEC/EN61008-1 GB/T16916.1
Release Type of Leakage Protection: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current: A/AC
May-23-19
 
Standard: IEC/EN61008-1 GB/T16916.1
Release Type of Leakage Protection: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current In: 16-63A (can be extended to 125A)
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current: A/AC
May-23-19
 
Standard: IEC/EN61008-1 GB/T16916.1
Release Type of Leakage Protection: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current: A/AC
Sep-02-06
 
Circuit breaker
Dec-02-16
Supplier From Wenzhou, Zhejiang Sheng, China
 
We manufacture and export Residual Circuit Breaker Nylon Body to our customers from Wenzhou, Zhejiang, China. NFIN series Residual current circuit breaker (without over-current protection) is suitable for the line of AC 50/60Hz,voltage 240V(2pole)/415V(4pole),rated current up to 63A.When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, RCCB will cut off the power rapidly to protect human safety and prevent the accident due to the current leakage.
It can be used as infrequent changeover of the line in normal situation. RCCB is applicable to industrial area, commercial area, tall building and civil house.
It complies with standard IEC/EN61008.1 and GB16916.1
Jun-28-13
 
Product Description
Residual current circuit breaker RCCB
Rated current: 25A, 32A, 40A,50A,63A,80A,100A
Rated sensitivity: 10mA, 30mA, 100mA,300mA
Product Feature
Feature (EBS6R Residual current circuit breaker )
1. Electro-magnetic release, voltage independent
2. High ability of withstanding short circuit current
Connection ( EBS6R RCCB )
Type of terminal: Lug type and pin type
Cables up to 35mm2
Product Specification/Models
Model: EBS6R RCCB ( Residual current circuit breaker )
Standard: IEC61008-1
Rated current In (A): 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A
Rated voltage Ue (V): 2 poles: 230VAC
4 poles: 230/400VAC
Poles: 2P, 4P

Standard export carton
Jul-30-18
Supplier From Yueqing, Zhejiang, China
 
5SM1 type Residual Current Device RCD is applying to the circuit breaker of AC/50/60Hz,220-250VAC single phase,415v three-phase and below it for industrial and mining enterprise,commercial building,and family,etc.To mainly prevent electric life and personal casualty accident caused by personal electric shock or leakage of electrified wiring.The RCCB is a currented-operated,fast leakage protector of electromagnetic type,which can break off fault circuit rapidly in order to avoid accident.The RCCB is in accordance with the standard of VDE0664,CEE27,BS4293 and IEC61008.
GOLD Member
Sep-03-10
Supplier From Mumbai, Maharashtra, India
Dec-02-16
Supplier From Wenzhou, Zhejiang Sheng, China
 
Main Specification
Trademark:CNHUNG/OEM
Poles:2P/4P
Rated current(A): 25,40, 63
Rated Voltage(V):AC230 / 400V
Frequency:50 / 60Hz
Rated residual action current(mA):30, 100, 300

-
VERIFIED
Jun-05-21

Terasaki Air Circuit Breaker

$1.39K
MOQ: Not Specified
Supplier From Anand, Gujarat, India
 
TERASAKI TEMPOWER ACB
TYPES: AT06, AT16, AT12, AT20, AT25, AT32, AT40.

TERASAKI TEMPOWER ACB
Type AGR-11B,21B,22B,31B Overcurrent Protective Device)
Types: AR208S, AR212S, AR216S, AR220S, AR325S, AR332S, AR440S, AR440SB, AR212H
AR216H, AR220H, AR316H, AR320H, AR325H, AR332H, AR420H, AR440H.
VERIFIED
Jun-05-21

Abb Vaccum Circuit Breaker

$2.78K
MOQ: Not Specified
Supplier From Anand, Gujarat, India
 
VACCUM CIRCUIT BREAKER
ALL TYPE OF ABB VACCUM CIRCUIT BREAKER
VD4 12.12.25 , VD4 12.12.40, VD4 07.12.25.... MANY MORE
11 KV , 33KV .
VD4Medium voltage vacuum circuit-breaker12 kV - 1250...4000 A - 63 kA36/40.5 kV - 630...3150 A - 16...40 kAMedium Voltage Products
The VD4 are a synthesis of the renownedtechnology in designing and constructing vacuuminterrupters embedded in resin poles, and ofexcellency in design, engineering and productionof medium voltage circuit-breakers.Embedding the interrupter in resin makes thecircuit-breaker poles particularly sturdy andprotects the interrupter against shocks, accumula-tion of dust and humidity.The vacuum interrupter houses the contacts andmakes up the interrupting chamber.
Jul-28-18
Supplier From Yueqing, Zhejiang, China
 
L7 2P 20A current circuit breaker is mainly used in AC50/60Hz single pole230V or two,three,four pole 400V voltage for overload and short-circuit protection as well as for infrequent on-and-off switching electric equipment and lighting circuit under normal conditional.

The product is suitable for industry,business,building,residence,etc.

It's conformity with GB10963,IEC60898 standards.
VERIFIED
Jun-05-21

L&t Air Circuit Breaker

$2.78K
MOQ: Not Specified
Supplier From Anand, Gujarat, India
 
BRAND:L&T LARSEN & TOUBRO
AIR CIRCUIT BREAKER C -POWER
ALL TYPE EDO AND MDO AVAILABLE.
Dec-16-05
 
Circuit breaker

The circuit breaker mainly serves for protecting the circuits of ac 50 hz, 230vof single pole,
230v/400v of two poles and 400v of three or four poles from overload or short-circuit, and also for unfrequent making and breaking electrical apparatus and lighting circuit.



Packed in export cartons
5331 Residual Current Circuit Breaker (Id Rcd ) Suppliers
Short on time? Let Residual Current Circuit Breaker (Id Rcd ) sellers contact you.
Explore Residual Current Circuit Breaker (Id Rcd ) related import export discussions