Model:S256

Name: Cellular 5-CH DC Electric Measuring RTU

The Cellular (GSM/GPRS/3G/4G/NB-IoT) DC Electric Measuring RTU is special designed for remote monitoring 5- channel DC electricity power. Measure each channel voltage, current, active power, active energy. When overload or exceed the pre-set value, then it will alert by SMS, Voice call, Cloud, APP, Wechat, Web Server, SCADA, HMI, DSC immediately.

The Cellular DC Electric Measuring RTU is an industrial class, high reliability, high stability, and programmable Remote Terminal Unit (RTU). It embedded 32-Bit High Performance Microprocessor MCU, integrated special measurement chip and inbuilt industrial Cellular module. It provides 4 digital inputs, 2 relay outputs, 1 ambient sensor input for monitoring onsite temperature and humidity.

Main Features:
1. Can be operated from anywhere, no distance limitation;

2. Quad band 850/900/1800/1900Mhz GSM GPRS Module inside.

3. 3G/4G/NB-IoT Modules are optional;

4. Modular design, can easily upgrade the cellular module if network upgrade;

5. Embedded ARM® Cortex�-M4 32 Bit RISC Core, 168 MHz inside, RTOS system, reliable performance with in-built watchdog;

6. Wide range power supply 12~36VDC with over voltage and phase-reversal protection;

7. Measurement range: voltage: 60V, 100V, 260V, 450V, 500V, current 5A, 20A, 50A.

8. Supports 5-Channel DC power: current, voltage, active power, active energy;

9. 4 digital inputs, compatibles dry and wet contact;

10. 2 relay output (5A/30VDC, 5A/250VAC), compatibles pulse outputs;

11. 1 ambient sensor input for monitoring onsite temperature and humidity;

12. Supports phase loss, phase recovery, voltage overload, current overload detection and alarm;

13. Inbuilt inter-lock logic programmer and powerful timer program function;

14. Resend the data while communication failure and alert to users by SMS;

15. Inbuilt TCP/IP protocol stack, supports cloud, APP and web server applications.

16. Supports Modbus TCP protocol, can integrate to SCADA, HMI, DSC directly.

17. Integrated 1 Industrial 10/100M adaptive Ethernet module inside, supports Modbus TCP;

18. Supports SMS Alert when overload, I/O triggered or recovery, and external power lost or recovery;

19. Provides 1 channel 12~36VDC power source output for external device, saving wiring cost;

20. Up to 10 SMS Alert and dial numbers, can program to receive specified alarm message.
Mar-20-20
 
16-CH Input module W/LED

* Support 16 isolated Input channels.

* Input channel support max. 50Hz counter

* Programmable Host Watchdog Timer for Host Failure Protection.

* Support Modbus and ASCII Format Protocol.
Mar-20-20
 
13 Channels Isolated Digital Output Module

* 13 Isolated Single-Ended output channels

* Open Collector Output (NPN)

* Programmable Host Watchdog Timer For Host Failure Protection.

* Support MODBUS RTU And ASCII Format
May-19-11
 
Product Structure

1. Bypass Cabinet (Optional)

The by-pass cabinet or switching cabinet may employ isolating breaker, vacuum contactor or the combination, depending on the user¡¯s working conditions. The function of by-pass cabinet is to put the motor into operation in industry frequency grid after the WLD-HVF exits, so as to ensure the continuity of user¡¯s production. The switching cabinet is designed to divert the WLD-HVF output to different motors.

2. Transformer Cabinet

Used for installation of Phase-shift transformer, it is dry type transformer with functions of temperature display and over-heat protection, also with insulation grade of H. The secondary multi-winding output provides phase-shift power supply to the power unit. This can greatly improve the current waveform on grid side and reduce the harmonic interference of the equipment to power grid lower of the National Criterion.

3. Power Unit Cabinet

Used for installation of power units, which adopted imported high quality components inside, all power units are installed on the sliding seat, it is very easy to replace.

4. Control Cabinet

Used for installation of low voltage control components, there are controller, PLC, UPS, Electric siren, DC 24V power supply, Control Power Source Switch, Wiring Terminals, Touch Screen, Operation Button etc.

The equipment adopted fiber optical communications, which has a very good EMI restraining performance; The transformer, control cabinet and all power units, are built in temperature protection, so it will be maintenance free.

Technical Features

Voltage source High-high frequency inverter, it can realize No-step speed regulation, which makes the typical motors into intelligent motors.
Low harmonics input and high power factor, the typical value for power factor is 0.95 through whole speed regulation, even more higher, no need for power factor compensation.
WLD-HVF output few harmonics, the motor does not generate extra heat and noise.
Modularized design of power units, interchangeable and easy to produce and repair, the equipment can find any fault exactly based on advanced diagnostic procedures in MPU.
The inverter still can operate even the faults for part of power units exists, if there are faults happen for inverter, the system can switch to power frequency through bypass function.
Applicable to all kinds of power grid at home and abroad and suitable for typical high voltage motor.
Colorful touch screen, easy to operate and maintenance.
Able to realize remote control, DCS operation and communications with Host, and support all kinds of communications interfaces such as CAN, Profibus, Modbus, RS232, RS485 etc.
Applied latest components, master control chip adopted TI¡¯s DSP F28335 and ALTERA¡¯s FPGA of EP3C to realize powerful processing capacity; Sampling adopted AD¡¯s AD7606 with 16 bit to ensure control accuracy of the system.
The switchgear can satisfy safety requirements, and the pressure-relief channel of high voltage switch can ensure safe use of operators.
Technical Parameters

Series No
Parameters
Value

1
HVF Capacity(KVA)
250~8750kVA

2
Power of adaptive motor(KW)
200~7000KW

3
Input Frequency(Hz)
45~65Hz

4
Harmonics contents injected to power grid
<3%

5
Rated input voltage(KV)
3KV/6KV/10KV ¡À10%

6
Input power factor
>0.95%(>20% of rated load)

7
Efficiency
>96%(under a rated load)

8
Output frequency(Hz)
0.5~120Hz

9
Precision of output frequency
0.01Hz

10
Rated output current(A)
36~600A

11
Overload capability
120%(1min), 150%(3s), 200%(Immediate protection)

12
Control mode
V/F control or Vector control

13
Analog input
0~10V/4~20mA

14
Analog output
0~10V/4~20mA Optional (2 channels)

15
Boolean input/output
Communications/Default point (expandable)

16
Acc & Dec time (S)
0.1~3000s

17
Altitude
<1000m

18
Protection grade
IP40

19
Cooling mode
Forced air cooling

20
Operation environment temperature
0~400C

21
Noise
<70DB

22
Communication with host
CAN, Profibus, Modbus, RS232, RS485 etc


Service

1. Perfect quality and service system

The company complies with ISO9001:2008 strictly to carry out production, process etc.

2. Pre-sale Service

Investigate and Survey onsite; Provide Feasibility study report; Assist in equipment specification selection; Analyse estimated energy saving effect etc

3. In-sale Service

Provide onsite installation and debugging training, Operator training, design paper&corresponding program, energy saving estimation and measuring etc

4. After-sale Service

The 24-hour timely and all-round service is available for all WLD-HVF users; Providing lifetime maintenance, onsite fault diagnosis, remote diagnosis etc.


Wooden case (Fumigation).
May-17-11
 
Product Structure

1. Bypass Cabinet (Optional)

The by-pass cabinet or switching cabinet may employ isolating breaker, vacuum contactor or the combination, depending on the user¡¯s working conditions. The function of by-pass cabinet is to put the motor into operation in industry frequency grid after the WLD-HVF exits, so as to ensure the continuity of user¡¯s production. The switching cabinet is designed to divert the WLD-HVF output to different motors.

2. Transformer Cabinet

Used for installation of Phase-shift transformer, it is dry type transformer with functions of temperature display and over-heat protection, also with insulation grade of H. The secondary multi-winding output provides phase-shift power supply to the power unit. This can greatly improve the current waveform on grid side and reduce the harmonic interference of the equipment to power grid lower of the National Criterion.

3. Power Unit Cabinet

Used for installation of power units, which adopted imported high quality components inside, all power units are installed on the sliding seat, it is very easy to replace.

4. Control Cabinet

Used for installation of low voltage control components, there are controller, PLC, UPS, Electric siren, DC 24V power supply, Control Power Source Switch, Wiring Terminals, Touch Screen, Operation Button etc.

The equipment adopted fiber optical communications, which has a very good EMI restraining performance; The transformer, control cabinet and all power units, are built in temperature protection, so it will be maintenance free.

Technical Features

Voltage source High-high frequency inverter, it can realize No-step speed regulation, which makes the typical motors into intelligent motors.
Low harmonics input and high power factor, the typical value for power factor is 0.95 through whole speed regulation, even more higher, no need for power factor compensation.
WLD-HVF output few harmonics, the motor does not generate extra heat and noise.
Modularized design of power units, interchangeable and easy to produce and repair, the equipment can find any fault exactly based on advanced diagnostic procedures in MPU.
The inverter still can operate even the faults for part of power units exists, if there are faults happen for inverter, the system can switch to power frequency through bypass function.
Applicable to all kinds of power grid at home and abroad and suitable for typical high voltage motor.
Colorful touch screen, easy to operate and maintenance.
Able to realize remote control, DCS operation and communications with Host, and support all kinds of communications interfaces such as CAN, Profibus, Modbus, RS232, RS485 etc.
Applied latest components, master control chip adopted TI¡¯s DSP F28335 and ALTERA¡¯s FPGA of EP3C to realize powerful processing capacity; Sampling adopted AD¡¯s AD7606 with 16 bit to ensure control accuracy of the system.
The switchgear can satisfy safety requirements, and the pressure-relief channel of high voltage switch can ensure safe use of operators.
Technical Parameters

Series No
Parameters
Value

1
HVF Capacity(KVA)
250~8750kVA

2
Power of adaptive motor(KW)
200~7000KW

3
Input Frequency(Hz)
45~65Hz

4
Harmonics contents injected to power grid
<3%

5
Rated input voltage(KV)
3KV/6KV/10KV ¡À10%

6
Input power factor
>0.95%(>20% of rated load)

7
Efficiency
>96%(under a rated load)

8
Output frequency(Hz)
0.5~120Hz

9
Precision of output frequency
0.01Hz

10
Rated output current(A)
36~600A

11
Overload capability
120%(1min), 150%(3s), 200%(Immediate protection)

12
Control mode
V/F control or Vector control

13
Analog input
0~10V/4~20mA

14
Analog output
0~10V/4~20mA Optional (2 channels)

15
Boolean input/output
Communications/Default point (expandable)

16
Acc & Dec time (S)
0.1~3000s

17
Altitude
<1000m

18
Protection grade
IP40

19
Cooling mode
Forced air cooling

20
Operation environment temperature
0~400C

21
Noise
<70DB

22
Communication with host
CAN, Profibus, Modbus, RS232, RS485 etc


Service

1. Perfect quality and service system

The company complies with ISO9001:2008 strictly to carry out production, process etc.

2. Pre-sale Service

Investigate and Survey onsite; Provide Feasibility study report; Assist in equipment specification selection; Analyse estimated energy saving effect etc

3. In-sale Service

Provide onsite installation and debugging training, Operator training, design paper&corresponding program, energy saving estimation and measuring etc

4. After-sale Service

The 24-hour timely and all-round service is available for all WLD-HVF users; Providing lifetime maintenance, onsite fault diagnosis, remote diagnosis etc.


Wooden case (Fumigation).
986 Modbus To Profibus Dp Built In Module Suppliers
Short on time? Let Modbus To Profibus Dp Built In Module sellers contact you.
Dec-08-20
 
Battery Monitoring Module BMS100 can be used in various industrial automation measurement and control systems. It can measure 4-20mA and 0-5V transducer signal of pressure, temperature,current,etc.It can measure server room battery management and voltage of each battery in each group.

1.Acquisition 2/4 channels of analog input 4 ï½? 20mA, 0 ï½? 5V, optional;
2.Adopt 12-bit AD acquisition processing, high accuracy measurement;
3.Standard Modbus-RTU protocol;
4.RS-485 (RS-422 optional) communication interface with ESD protection circuit;
5.Wide working voltage DC9 ï½? 36V, with anti-reverse protection function ;
6.Using industrial-grade chip, built-in watchdog, and has perfect anti-lightning and anti-interference measures to ensure reliability;
7.Configurable maximum and minimum value of analog input, intelligent conversion of actual value, convenient for various analog measurement requirements;
8.Can measure 12 single battery voltages,several battery group and 1 total voltage;
9.It has 3 precision gears for different voltage ranges to improve the voltage measurement accuracy;
10.With LED light to indicate working status, easy to install and debug on site.
Oct-29-20

Gear Hob M1-M40 / Dp120-Dp0,7

$150 - $15.00K
MOQ: Not Specified
 
Module : 0,1 - 40
DP : 120 - 0,7
PA : 14.30 - 15 - 17.30 - 20 - 22.30 - 25 - 27 - 30 - 45

Delivery from stock.

Express shipping via TNT.
Jul-04-07
Supplier From Delhi, Delhi, India
Aug-08-08
Supplier From Ningbo, Zhejiang, China
Dec-08-20
 
The Cellular Electricity Power IoT RTU is a powerful smart meter used for power internet of things solution, is special using for remote monitoring 100~400VAC of 3-Phase electricity power distribution safety and measurement, can measuring the 3-phase 3-wire, 3-phase 4-wire distribution power voltage, current, factor, watts, frequency, apparent power, active power, reactive power, active energy, reactive energy. Also, it provides Dual SIM, 2 digital inputs, 2 relay outputs, 1 ambient sensor input for monitoring onsite temperature and humidity, also 1 RS485 for extend I/O to monitoring oil level and temperature or read meters.

1. Can be operated from anywhere, no distance limitation;

2. Quad band 850/900/1800/1900Mhz GSM GPRS Module inside.

3. 3G/4G/NB-IoT Modules are optional, LCD Display is optional;

4. Modular design, can easily upgrade the cellular module if network upgrade;

5. Embedded ARM�® Cortexâ?¢-M4 32 Bit RISC Core, 168 MHz inside, RTOS system, reliable performance with anti-jamming and in-built watchdog;

6. High isolate voltage, current and voltage input signal isolated by accuracy transformer, afford arrive DC2500V;

7. Working Voltage: 60~500VAC or 70~800VDC;

8. 3-phase 3 wires or 4 wires power parameter measurement, include voltage, current, factor, watts, frequency, apparent power, active power, reactive power, active energy, reactive energy, phase loss;

9. Measurement range: AC100~400VAC, currant range: 5A, other range should use CT;

10. 2 digital inputs, compatibles dry and wet contact, 2 relay output (5A/30VDC, 5A/250VAC), compatibles pulse outputs;

11. 1 ambient sensor input for monitoring onsite temperature and humidity ;

12. 1 RS485 port, supports Modbus RTU Master and Slave, can be used to extend I/O ports or meters;

13. Provides 1 channel DC power source output for external device, saving wiring cost;

14. Each parameter can setup threshold, when exceed or recovery will alarm immediately;

15. Can monitoring phase loss, when occurs will alarm immediately.

16. Inbuilt inter-lock logic programmer and powerful timer program function.

17. Resend the data while communication failure and alert to users by SMS;

18. Inbuilt TCP/IP protocol stack, supports cloud, APP and web server applications;

19. Supports Modbus TCP, Modbus RTU protocol and transparent transmission, can be used as master and slaves, can integrate to SCADA, HMI, DSC directly;

20. Supports USB setting, reading, records inquiry and firmware upgrade;
Apr-15-20
Supplier From Chongqing, China
 
BJ194E-9S4, with its four direct access keys and LED displays, helps you use all the parameters in 3P3W or 3P4W LV installation.

These parameters can be centralized on a PC or PLC through an RS 235 link using MODBUS protocol. The casing is designed so that the installer can easily fit the meter to the door of a cabinet.

Applications

1. Metering of distribution feeders, transformers, generators, capacitor banks and motors
2. Medium and low voltage systems
3. Commercial, industrial, utility



Features






1.Class 0.2 or 0.5 power and energy
2.Current measuring .../5 or .../1 A
3.Option RS-232 Modbus/RTU Communications
4.Expandable input / output modules (up to 3 modules)
5.ITF Technology: galvanic insulation protection inputs outputs
6.Universal series power supply
Nov-07-14
 
Built-in shuttle knop to adjust output frequency easily
Built-in rs-485 communication interface
Support modbus and shihlin communication protocol
Built-in proportion linkage control function to support multi inverters connection
Maximum 650hz frequency output enable to support special and high-speed motors.
Support din rail mount
The resolution of frequency setting: digital 0.01hz ; analog 1/1000
The accuracy of output frequency: 0.01%
Multi-function input/output terminals
Support 2 analog setting types. 0-10v and 4-20ma
May-19-18

M120T Scada System Modem

$1
MOQ: Not Specified
Supplier From Shenzhen, Guangdong, China
 
Name:Modbus TCP Ethernet Remote IO Module (4DI+4DO+RJ45+RS485)

Introduction:

The M120T Ethernet Remote I/O module provides 4 optical-isolated digital inputs, supports 1~300KHz high speed pulse counter, 4 isolated 12bits analog inputs, supports 0~5V,0~10V,4~20mA,0~20mA analog signal, 4 digital outputs, supports 1~300Khz high speed pulse output or relay outputs, 2 channel 12bits analog outputs, supports 0~10VDC signal output.

The M120T Ethernet Remote I/O Module is an industrial class, isolated designed, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, Integrated 1 Industrial 10/100M adaptive Ethernet module inside. It provides multi I/O, supports standard Modbus TCP, can be intergraded into SCADA, OPC server, and other automation systems.

he M120T Ethernet Remote I/O module provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements.

Features:

1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;

2. Wide range power supply 12 ~ 36VDC with over voltage and phase-reversal protection;

3. Embedded Web server for configuration and management;

4. Integrated 10/100M adaptive Ethernet module, supports Modbus TCP protocol;

5. 4 optical isolated digital input, supports 1~300KHz high speed pulse counter;

6. 4 digital output or relay output, supports 1~300KHz high speed pulse output;

7. 4 isolated analog input, 12-bit resolution, supports 0~20mA,4~20mA,0-5VDC,0-10VDC;

8. 2 analog output, 12-bit resolution, supports 0-10VDC

8. High sampling frequency and special filtering strategy to ensure reliability;

9. 1 RS485 Serial port, supports Modbus RTU/ASCII Master, can extend I/O modules;

10.Supports register mapping function and extend I/O inquiry strategy;

11. Provides 1 channel 12`36VDC power source output for external device, saving wiring cost;

12. LED instructions work status, with reset button to reset, easy on-site installation and commissioning;

13. Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;

14. Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.
Jul-10-14
 
Ferent flow signal;
6. Inside have three counters, which can separately show positive cumulation, reverse cumulation and d-value
Flow direction forward / reversed
Electrodes material 316l / hastelloy c2, b4/tantalum/titanium/platinoiridita/others
Liner material rubber /ptfe/pfa pfa ptfe
Electrodes type standard
Qty of electrodes 2 pairs ( one pair for measuring, one pair for grounding) 1 pair( for measuring)
Measuring tube material 304 stainless steel
Flange material carbon steel/304 stainless steel 304 stainless steel 304 stainless steel
Installation type wafer/flange tri-clamp/screw flange/plug-in
Protection level ip65/p68 ( remote version)
Power 220vac ± 20% 60hz / 24 vdc
Signal output 4~20ma
Communication hart / modbus/ profibus
Electrical connection 2* m20 * 1.5
Explosive-proof exdemib ii bt3~t6
Construction type compact / remote
Operation environment environment temperature: -25 ° c~ + 60 ° c; relative humility: 5% ~90%

Wooden box
Mar-20-20
 
EDAM-9053A
12 DI (Dry/Wet contact) and 4 DO channels Digital I/O module

* Support Modbus/TCP,TCP/IP,UDP,ICMP,ARP

* Ethernet 10/100 Based-T Communication

* Support 4 Isolated digital output channels (NPN).

* Provide Pulsed/delay Output Mode

* Support 12 Isolated digital Input Channels

* Provide Counter/ Frequency Inputs Mode

* Support Dry/ Wet Contact Inputs

* Fully Photo-Isolation 3750Vrms

* Status LED indicator
Mar-20-20
 
EDAM-9050
12 DI and 6 DO channels Digital I/O Module

* Support Modbus/TCP,TCP/IP, UDP, ICMP, ARP

* Ethernet 10/100 Based-T Communication

* Support 6 Isolated digital output channels (NPN).

* Provide Pulsed/delay Output Mode

* Support 12 Isolated digital Input Channels

* Provide Counter/ Frequency Inputs Mode

* Support Dry Contact Inputs

* Fully Photo-Isolation 3750Vrms

* Status LED indicator
Mar-20-20
 
EDAM-9015
Ethernet-Based 7-ch RTD Input Module

* Support PT100,PT1000, Balco 500,NI604, NI1000 RTD Types

* Support Protocol Modbus/TCP, TCP/IP, UDP, ICMP, ARP

* Ethernet 10/100 Based-T Communication

* Support Isolated Input Channels

* Fully Photo-Isolation 3750Vrms

* Wide Supply Voltages (10-30V)

* Bulit-in TVS/ESD Protection

* Bulit-out Auto Detection
Mar-26-20
Supplier From New Taipei, Taiwan
 
EDAM-8066D
8-ch Photo-MOS relay Output module with LED display

1. 8-Channels Isolated Output

2. Normal Open PhotoMOS Relay Output

3. Typical applications:

* High-speed inspection machines

* Telephone equipment

* Data communication equipment

4. Programmable Host Watchdog Timer For Host Failure Protection.

5. Support MODBUS RTU And ASCII Format Protocol.
Mar-26-20
Supplier From New Taipei, Taiwan
 
EDAM-8024
4 analog output and 4 digital input channels module

* 4 isolation analog output channel .

* 14 bits Analog Resolution

* Programmable voltage/current range with slew rate.

* 4 channels isolation digital input

* 3000 Vrms isolation voltage for A/O channel

* Programmable power-on value and safe value

* Programmable host watchdog timer for host failure protection.

* Support ASCII format and Modbus-RTU protocol
Mar-20-20
 
EDAM-9051
12 DI, 2 DO and 2 Counter channels Digital I/O Module

* Support Modbus/TCP,TCP/IP,UDP,ICMP,ARP

* Ethernet 10/100 Based-T Communication

* Support 2 Isolated digital output channels (NPN).

* Provide Pulsed/delay Output Mode

* Support 12 Isolated digital Input Channels

* 2 counter (4.5 KHz) input channels

* Support Dry Contact Inputs

* Fully Photo-Isolation 3750Vrms

* Status LED indicatorr
986 Modbus To Profibus Dp Built In Module Suppliers
Short on time? Let Modbus To Profibus Dp Built In Module sellers contact you.
Explore Modbus To Profibus Dp Built In Module related import export discussions