Please click here to check who's online and chat with them.

Find Verified Modbus Rtu To Fieldbus Ff Built In Module Suppliers, Manufacturers and Wholesalers

Sep-09-11
Supplier From Shenzhen, Guangdong, China
 
Remote Monitoring your assets in anywhere and anytime!
An Innovative GPRS RTU to reduce your management costs!
GSM GPRS RTU Telemetry Data Logger
GSM GPRS RTU Telemetry Data Logger M2M
GPRS Terminal with RS485
GPRS Telemetry with SCADA
GPRS Data Logger with Modbus RTU protocol
GPRS Controller with Modbus RTU protocol

GSM GPRS RTU Telemetry Data Logger S240 equipped Siemens MC55i quad-band GSM Module inside, is a low cost, M2M, data logger, universal GSM GPRS Engine which can transmit and receive analog, digital and pulse counter data, PLC, Varity metering equipments to any device connected to the GSM/GPRS network such as mobile phones, Web Sites, monitoring center, control room, SCADA, etc.

The features and functions of GSM GPRS RTU Telemetry Data Logger S240:
1) Quad-band Siemens MC55i GPRS Module and High-density performance line ARM 32-bit MCU inside;
2) Direct connection to the GSM GPRS Network;
3) Transparent Serial Data Tunneling using low cost SMS/GPRS network;
4) Remote Configuration by SMS Messages or GPRS;
5) Upload data via GPRS or SMS on Schedule or event occurs;
6) Supports Dynamic Domain name or Static IP address;
7) Supports SMS, GPRS UDP and TCP protocols;
8) Supports Modbus RTU protocols;
9) 1USB Port, 1 RS232 Serial Port, and 1 RS485 Serial Port;
10) 6 Opto-isolated digital inputs can be programmed to NC/NO/Edge/Level type by switch, Passive Contact Type and Active Contact (3~24VDC) type can be programmed by DIP switch, DIN1 and DIN2 are Completely isolated. when alarm occurs can send Alarm Messages by SMS or GPRS or auto dial the preset phone numbers;
11) 6 digital inputs can be used as Pulse Counters;
12) 4 Digital Relay Outputs can be programmed as dial to switch on/off with free communication fee, alarm-linkage and Schedule to action, also can be send SMS to switch on/off;
13) 10 Analog Inputs. (12 bit resolution, 0-5V or 0-20mA);
14) 2 Thermometer Inputs for DS18B20, measures temperatures from -55¡ãC to +125¡ãC. Fahrenheit equivalent is -67¡ãF to +257¡ãF, ¡À0.5¡ãC accuracy from -10¡ãC to +85¡ãC, Thermometer resolution is programmable from 9 to 12 bits;
15) 4 Power Source Outputs for external device, like Thermometer or transducer, 3 with 3.3V/400mA, another with 12VDC/750mA;
16) Supports 1 SMS Center Number and 1 IP address or 1 Dynamic Domain name;
17) User friendly PC Programming Interface, it can remotely program the terminals as well as to upload the data from the terminals by SMS or GPRS, all of the Current Value or status of the terminal can be display directly, and also will display the SMS Command details while you programming it;
18) More Protocols can be updated by user through USB Port with the updated firmware;
19) Power supply 9V to 24V(Recommend 12VDC);
20) Size: 168mm*113mm*32.3mm.


Standard packing list of GSM GPRS RTU Telemetry Data Logger S240:
1X Mainframe
1X AC/DC adaptor
1X User Manual(CD)
1X GSM ANT
PC Configurator is free charge in the CD
With internal back up battery.
Oct-31-19
 
NCS Series of Intelligent Transmitters are digital, intelligent, network-based, merged with advanced, reliable and stable sensor technology, to be designed as a new generation of Fieldbus Intelligent Transmitter.



NCS Series of Intelligent Transmitter have been designed with high precision and high reliability, high stability. The pressure, temperature, currents and other physical quantities are displayed on LCD module. Zero drift, range settings and many other functions, are realized by the magnetism bar operation. The interoperability between different systems and equipments are realized by the Equipment Description Document, which is compatible to a variety of device management software, and adapting to harsh electromagnetic environment. NCS Series of Intelligent Transmitter have been used in inflammable and explosive places according to Intrinsically Safety Design.

The Fieldbus Technology is used in NCS-TT105 Intelligent Temperature Transmitter, which is a new generation of Fieldbus Intelligent Temperature Transmitter, also an indispensable field device in control processing. It is integrated with a variety of functional modules, to realize not only the general testing functions, also the complicated control strategy.



Digital technology is applied in NCS-TT105, which has been used in a wide range of thermal resistance and thermocouple sensors. It has a wide measuring range. Because of the simple interface between the field and control room, the costs of installation, operation and maintenance are reduced a lot.



NCS-TT105 Series of Intelligent Temperature Transmitters, complied with FF Protocol, have been widely used in petroleum, chemical, metallurgy, electricity, cement,etc.



Thermo resistance additional parameters as follows:



Parameter

Function Description

COMP_WIRE1

Linearization compensation for thermo resistance 1 selecting 2-wire or 3-wire.

Unit is fixed as Ω.

COMP_WIRE2

Linearization compensation for thermo resistance 2 selecting 2-wire or 3-wire.

Unit is fixed as Ω.

SENSOR_CONNECTION

It can be used to connect sensor with 2-wire or 3-wire.

0: 2-wire

1: 3-wire
Oct-17-17

Modbus To Hart Gateway

$199
MOQ: Not Specified
 
1.Modbus-RTU protocol to HART protocol
2.Support 6 device variables and 4 dynamic variables
3.Support Modbus communication parameters dynamic configuration
4.Support HART multipoint mode
5.Support 375/475 communicator
Apr-15-20
Supplier From Chongqing, China
 
BJ-192/193 series especially developed for indication and supervision of the three-phase circuit, replaces an analogical display meter, reducing installation manpower and optimizing the used one of spaces in the panel.

Ideal for protection of single phase and three-phase networks, it is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.



Features:




·Class 0.5(192 series)/0.5S(193 series) electrical parameter measurement
·Current measuring .../5 or .../1 A
·Measurement function cover:
Current, Voltage, total three-phase power, power factor, frequency
·RS-485 MODBUS-RTU Communications
·Expandable input / output modules (1 modules)
·ITF Technology: galvanic insulation protection inputs outputs
·Large character LED Screen display
·Optional various install sizes
Apr-15-20

193I 0-5A Digital Ac Ammeter With Rs-485

$20 - $30
MOQ: Not Specified
Supplier From Chongqing, China
 
BJ-192/193 series especially developed for indication and supervision of the three-phase circuit, replaces an analogical display meter, reducing installation manpower and optimizing the used one of spaces in the panel.



Ideal for protection of single phase and three-phase networks, it is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.





Features





·Class 0.5(192 series)/0.5S(193 series) electrical parameter measurement

·Current measuring .../5 or .../1 A

·Measurement function cover:

Current, Voltage, total three-phase power, power factor, frequency

·RS-485 MODBUS-RTU Communications

·Expandable input / output modules (1 modules)

·ITF Technology: galvanic insulation protection inputs outputs

·Large character LED Screen display

·Optional various install sizes
1013 Modbus Rtu To Fieldbus Ff Built In Module Suppliers
Short on time? Let Modbus Rtu To Fieldbus Ff Built In Module sellers contact you.
Apr-15-20
Supplier From Chongqing, China
 
Especially developed for indication and supervision of the low-medium voltage three phase electrical network measurement also can be used in DC circuit. It can replaces other analogical panel meter reducing installation manpower and optimizing the used one of spaces in the panel.





Features:





·Class 0.5(192 series)/0.5S(193 series) electrical parameter measurement

·Current measuring .../5 or .../1 A

·Measurement function cover:

Current, Voltage, total three-phase power, power factor, frequency

·RS-485 MODBUS-RTU Communications

·Expandable input / output modules (1 modules)

·ITF Technology: galvanic insulation protection inputs outputs

·Large character LED Screen display

·Optional various install sizes
Jun-19-14
 
Features:
> > 8 channel 4~20ma signal acquisition, channel to channel is isolated
> > testing accuracy> 0.05%
> > rs485/232 output, can programme the accuracy of module
> > input/output/power supply three-port isolation: 3000vdc
> > wide power supply: 8~50vdc
> > high reliability, programming convenience, easy to install.
> > users can set module address, baud rate.
> > support modbus rtu communication protocal

Applications
> > temperature signal testing/monitoring/cintrol
> > rs232/485 industrial automation control system
> > industial field signal isolation
> > process monitoring & control
> > test sensors signal
> > laboratory data acquisition
> > medical machine monitoring
> > 4~20ma signal acquisition

Dimensions:123*70*30mm
Oct-25-13

Rtu

MOQ: Not Specified
Supplier From Haidian, Beijing, China
 
Overview
The super32-l is a series of compact rtu that brings advanced automation capabilities and open programming to applications requiring small i/o points. It is built on a high performance 32-bit processor with embedded real-time operating system to meet all monitoring and control requirements. A broad array of communication ports and extensive protocol library provide broad network compatibility. Super32-l also offers an open programming environment that supports all iec61131-3 languages. A rich library provides numerous pre-engineered function blocks, which project engineers find invaluable.

Features
High performance 32-bit cpu with embedded real-time operating system (rtos)compact design with up to 25 i/o points and 4 communication ports extensive communication protocols such as modbus rtu/ascii/tcp, dnp3 open programming environment that supports all iec61131-3 languages including ld, fbd, il, st and sfc built-in watchdog timer helps to protect your application from erroneous outputs
All the terminal blocks are isolated from the main control circuit.


Carton
Oct-25-13
Supplier From Haidian, Beijing, China
 
Overview
The super32-l is a series of compact rtu that brings advanced automation capabilities and open programming to applications requiring small i/o points. It is built on a high performance 32-bit processor with embedded real-time operating system to meet all monitoring and control requirements. A broad array of communication ports and extensive protocol library provide broad network compatibility. Super32-l also offers an open programming environment that supports all iec61131-3 languages. A rich library provides numerous pre-engineered function blocks, which project engineers find invaluable.

Features
High performance 32-bit cpu with embedded real-time operating system (rtos)compact design with up to 25 i/o points and 4 communication ports extensive communication protocols such as modbus rtu/ascii/tcp, dnp3 open programming environment that supports all iec61131-3 languages including ld, fbd, il, st and sfc built-in watchdog timer helps to protect your application from erroneous outputs
All the terminal blocks are isolated from the main control circuit.


Carton
Nov-21-20
 
1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;
2. Wide range power supply 12 ~ 36VDC with over voltage and phase-reversal protection;
3. Management and configuration via LAN connection configuration software for easy operation and maintenance;
4. Integrated 10/100M adaptive Ethernet module, supports Modbus TCP protocol;
5. 16 digital output or relay output, supports 10Hz~300KHz high speed pulse output;
6. High sampling frequency and special filtering strategy to ensure reliability;
7. 1 RS485 Serial port, supports Modbus RTU/ASCII Master, can extend I/O modules;
8. Supports register mapping function and extend I/O inquiry strategy;
9.Provides 1 channel 12~36VDC power source output for external device, saving wiring cost;
10.LED instructions work status, with reset button to reset, easy on-site installation and commissioning;
11.Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;
12.Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.
Nov-25-20
 
The Dual Simcard Cellular IoT Modbus RTU is design for working in the harsh industrial application environment, converting Modbus TCP/RTU to SMS and cloud platform. widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system, BTS monitoring, remote data acquisition, telemetrically systems, automatically control system. It can be used as a remote switch, remote I/O, remote smart PLC, timer switches. Supports SMS,GPRS,3G, 4G Lte Cellular Networks.Compatible Modbus TCP and MQTT IoT Protocols and can intergrate to the KPIIOT IoT Cloud Platform and OPC, SCADA and MES systems.
Oct-25-13
Supplier From Haidian, Beijing, China
 
S an independent local controller or act as a remote substation for a scada system.
Features
Monitor rod pump operation and periodically collect dynamometer, pressure, temperature and fluid level data.
An advanced algorithm used to control the rod pump operating at the optimized condition to improve energy efficiency.
Open iec1131-3 programming environment for users to develop their specific application.
With an embedded rf module, the e5302 can communicate with wireless dynamometer sensor, wireless pressure transmitter, wireless temperature transmitter to build up a cost-effective wireless data acquisition system.
Provide three serial communication ports and one ethernet port. It can be connected to many communication devices including ap, radio, and gprs dtu.
Support industrial standard modbus rtu and e4100 protocols.
Remote controlled by central computer system.


Carton
Oct-25-13
Supplier From Haidian, Beijing, China
 
Monitor rod pump operation and periodically collect dynamometer, pressure, temperature and fluid level data.
An advanced algorithm used to control the rod pump operating at the optimized condition to improve energy efficiency.
Open IEC1131-3 programming environment for users to develop their specific application.
With an embedded RF module, the E5302 can communicate with wireless dynamometer sensor, wireless pressure transmitter, wireless temperature transmitter to build up a cost-effective wireless data acquisition system.
Provide three serial communication ports and one Ethernet port. It can be connected to many communication devices including AP, Radio, and GPRS DTU.
Support industrial standard Modbus RTU and E4100 protocols.
Remote controlled by central computer system.




Carton
Nov-01-20
 
Industrial design, stable and reliable, suitable for harsh environment;
Support 4, 8 and 16 digital DO outputs, widely used;
DO1 supports PWM high-speed pulse output, frequency: 10Hz ~ 300KHz;
DO2 can be used to control the direction output of stepper motor and servo motor;
1 RS485 supports Modbus master and slave protocol for expanding IO or HMI;
One RJ45 Ethernet interface supports TCP Server and TCP Client services;
Support Modbus TCP and MQTT protocols, can access SCADA, MES and cloud platforms;
As a TCP server, it can support 5 TCP links at the same time.
Nov-22-20
 
1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;
2. Power supply 12~36VDC with over voltage and phase-reversal protection;
3. Supports TCP Server, TCP Client, Modbus TCP, MQTT Protocols;
4. DO1 support PWM output;

5. Management and configuration via LAN connection configuration software for easy operation and maintenance;

6. 8 optical isolated digital input, supports max. 700khz high speed pulse counter;
7. 8 digital output or relay output, supports 10Hz~300KHz high speed pulse output;
8. 8 isolated analog input, 12-bit resolution, supports 0~20mA,4~20mA,0-5VDC, 0-10VDC;
9. High sampling frequency and special filtering strategy to ensure reliability;
10.1 RS485 Serial port, supports Modbus RTU Master or Slave, can extend I/O modules;
11.Supports register mapping function and extend I/O inquiry strategy;
12.Provides 1 channel 12~36VDC power source output for external device, saving wiring cost;
13.LED instructions work status, with reset button to reset, easy on-site installation and commissioning;
14.Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;
13.Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.
Dec-09-20
 
Model noï¼?S281

The Lora Gateway S281 is the latest Lora technology for industrial internet of things solutions. It supports upto 99 wireless temperature humidity modules, and 99 wireless serial port modules with a monitoring radius of upto 2500m.it is widely used in agricultural greenhouse temperature and humidity collection and monitoring, chemical plant temperature and humidity collection and monitoring, electroplating plant temperature and humidity collection and monitoring, hospital sites and fruit and vegetable storage warehouses and other places temperature and humidity collection and monitoring. Supports SMS,GPRS,3G, 4G Lte Cellular Networks.Compatible Modbus TCP and MQTT IoT Protocols and can intergrate to the KPIIOT IoT Cloud Platform and OPC, SCADA and MES systems to build an industiral IoT Solution.
Dec-09-20
 
Model no S266

The S266 GSM GPRS SMS 3G 4G Temperature Monitoring Unit can be used for remote monitoring onsite temperature, once the temperature exceeds the preset value, will send SMS to 10 user numbers to alarm. also, it supports GPRS/3G/4G to transfer data to remote monitoring center,supports modbus tcp,can intergrate to SCADA,KPIIOT Cloud platform directly.
Advantages

Quad band 850/900/1800/1900Mhz GSM GPRS Module inside;

3G UMTS/HSDPA/4G Modules are optional.;

32 bit MCU, reliable performance with in-built watchdog;

Support temperature & humidity monitoring remotely in real-time;

Support 8 channel temperature input interface(DS18B20 Temperature sensors);

Support 2 relay outputs,7A@125VAC 5A@125VAC 20A@14VDC;

High/Low Alert via SMS/Call/GPRS;

Supports 1 DNS or IP address as server;

Supports Modbus TCP, TCP/IP protocol over GPRS/3G/4G network;

Automatically resend the data while communication failure, GPRS failure will alert by SMS text;

Supports remotely restart the device, and configure it by SMS commands remotely;
Up to 10 user's phone number to receive alarm and daily report SMS/Call;

Timer report, interval period 1~65535 seconds, configurable; automatically upload status/Value to the authorized numbers;

In-built rechargeable battery, power lost/recover alarm, low maintenance, 247 operation;

In-built internal clock, support 11 actions on schedule at pre-set time;
Internal 16MB memory, logs more than 200000 records;

Wall mount or 35mm standard DIN rail Design, convenient installation, Dimensions 70*88*30mm;

Support Android/IOS APP, easily & friendly for use/config.

Support remote upgrade the firmware via PC.
Can be operated from anywhere, no distance limitation;

Secure - Using caller ID and password for identification, unknown callers are ignored;
Mar-20-20
 
EDAM-9017
Ethernet-Based 8-ch Isolated Analog Input Module

* Support protocol Modbus / TCP/ IP, UDP, JCMP, ARP

* Provides two digital outputs (open collector)

* Ethernet 10/100 Based-T communication

* Support isolated input channels

* Support +- V, +- mV, mA analog input

* Fully photo-isolation 3750Vms

* Built-in TVS/ESD protection

* Wide supply voltage (10-30V)
Jul-25-11
 
Detailed Product Description
xLogic is latest Micro PLC, replacing mini plc,multiple components, easy installation, minimum wiring, easy programming!

Description
ELC-12 range is advanced level model, incorporating a good mix of digital & analogue IO , Integrated High Speed inputs and PWM output, counters, timers,real time clock and time switch functions, removable keypad LCD, 3 built-in communication ports including expansion one. Available in 120V/240VAC or 12V/24VDC versions ; Easy to configure with drag-and-drop function blocks or ladder using FREE xLogicSoft software.

ELC-12 range offers 4-line detachable LCD display and keypad for manual programming without PC, program modification or display and control whilst program is running. An expansion port allows the connection of up to 8 expansion modules, extending the I/O channel count and adding Ethernet capabilities. Now it is also possible to use the analog output module to solve simple closed-loop control tasks. Heating and cooling systems can be designed with the RTD PT100 module using special functions for PI control, ramp response and analog multiplexer.

xLogic ELC-12 Series(standard type) highlights at a glance:
Removable LCD with keypad for manual programming, operator interface or maintenance troubleshooting ( Learn more)

v Customizable Start-up page / screen
v 4-line, 10-character configurable backlighting display
v Manual programming via Keypad panel without PC capability (optional)
v Various blocks¡¯ different parameters can be displayed on one screen / page simultaneously
v Randomly specify a specific page to display the IO status of the ELC 12 or expansion module attached
v Ethernet capability available .
v Alarm page can record and display the exact alarm occurrence time
v Programmable up to 64 (user defined) screens / pages
v Optional metal mounting plate offers mounting to the rear of the control panel door.
v Modbus RTU &ASCII protocol supported.
v Unit Size allows for DIN-rail mounting together with commonly used breakers in building automation applications.
v Retentive memory capability standard feature on the ELC-12 model.
v Powerful communication capability(1 RS232 port and 2 RS485 ports built-in)
v It's optional for xLogic to act as slave or master in Modbus RTU communication network.
v Extra large program capacity ( 512 function blocks available)
v HMI(LCD) separate installation available, e.g. xLogic can be installed inside electric cabinet and HMI/LCD mounted in it¡¯s front panel for easier observation and convenient operation

GENERAL SPECIFICATIONS

Timers : 512
Counters : 512
Function Blocks : 512
Operation temp.: 0¡ãC-55¡ãC
Storage :-40¡ãC-70¡ãC
Protection : IP20(Non-waterproof)
RTC accuracy : MAX ¡À5S/day
RTC time intervals : 256
RTC Backup at 25 ¡ãC : 100 hours, Li-ion battery (optional)
Power-off retentivity : Yes
Dimensions : 72*90*68 (Unit, mm)
Certificate : CE
Installation : DIN rail or screw for installation
Expansion capacity : yes
Password protection : password protection
Communication interface : 1 RS232 port ( TTL interface) & 2 RS485 ports
Communication protocol : Modbus RTU/ASCII
It's optional for xLogic to be either slave or master in Modbus network.

Area of application
Contributed to xLogics versatile features, The xLogic can be used in numerous applications:
Machine controls
Motor, pump and valve controls
Air compressors
Exhaust and filtering systems
Water-treatment plants
Woodworking machinery
Etching and purification plants

Transport facilities
Conveyor systems
Hoisting platforms
Elevators
Silo facilities
Livestock feed delivery

Operational monitoring systems
Access control
Vehicle control monitoring
Alarm systems
Level limit monitoring
Traffic light control systems
Baggage handling


Residential and commercial building services
Interior and exterior lighting control
Door/gate control
Shutter, sun blind and awning control
Irrigation system control

Unique applications
Wind power systems
Harsh environments
Display panels and traffic control signs

Benefit
the ideal solution for simple automation tasks
Minimizes costs - replaces many conventional switching control devices,
reduces time requirements ¨C simplified wiring and panel layout,
Offers flexibility in resellers stock selection by offering removable keypad display
Saves much space in the switching cabinet - modules based on a 4 width industry standard dimension replace a wide variety of relays, timer switches and contactor relays
Furnishes the widest range of capabilities and successful implementation of extensive applications with the option of selecting from 44 integrated functions and linking up to 512 of them in the user program.
Operator control and monitoring are made very user-friendly by means of a 4 line, 10 characters per line, backlit display.
Additional external text display extends the possibilities for operator control and monitoring
Password protection ¨C Protects your engineering IP .
44 integrated, pre-tested functions ¨C No additional devices, such as elapsed time counter, are required
Linking of 512 functions is possible ¨C Extensive applications can be implemented without restrictions
Eight digital inputs (incl. four AIs at 12 / 24 V DC) and four digital outputs on board
Display of message texts, action items and current values as well as direct modification of the values on the display
Retentive data memory ¨C Protects current values against loss in the event of a power failure
Together with the xLogicSoft software, configuring of the xLogic is simply intuitive: program generation, project simulation and documentation are accomplished using drag and drop functionality, allowing maximum ease of operation.
Oct-30-19
 
Product Overview

NCS-TT106 smart temperature module, using the fieldbus technology, is a new generation of smart fieldbus temperature transmitter and it is an indispensable field device for process control.

Features

Support multiple thermal resistance and thermocouples
Thermal resistance supports 2/3/4-wire connection mode
Thermocouple can use cold end compensation function
Better accuracy: PT100 ±0.3 ; K-type ±0.4
Universally programmable for various input signals
Available protocols: HART /FF H1 /PROFIBUS PA
Parameter

Value

Input Signal

Resistance: PT100, CU50, CU100, 0~500Ω, 0~4000Ω

Thermocouple: B, E, J, N, K, R, S, T

Voltage signal: -100mV~100mV

Channel Single

RTD Wiring 2-wire, 3-wire, 4-wire

Bus Power 9~32 VDC Current consumption (static): â?¤14mA

Bus Signal Communication ratio 31.25Kbit/s, current mode

Isolation Between terminal and housing: 1kV

Working Temperature -40~85

Humidity Range 10%~90%RH

Start Time â?¤5s

Refresh Time 0.5s

EMC GB/T 18268-2000

Protection IP20

Signal Type Suggested Range ()

Accuracy
Resistance 0~500Ω,0~4000Ω ±0.05%
PT100 -200 ~ 850 ±0.2
PT1000 -200~ 850 ±0.1
CU50 -50 ~ 150 ±0.3
CU100 -50 ~ 150 ±0.2
mV -100mV ~ 100mV 0.05%
B 500 ~ 1810 ±1.0
E -200 ~ 1000 ±0.4
J -190 ~ 1200 ±0.4
K -200 ~ 1372 ±0.4
N -190 ~ 1300 ±0.8
R 0 ~ 1768 ±1.0
S 0 ~ 1768 ±1.0
T -200 ~ 400 ±0.4