Please click here to check who's online and chat with them.

Find Verified Modbus Rtu To Fieldbus Ff Built In Module Suppliers, Manufacturers and Wholesalers

Mar-18-20
 
8 Isolated Analog/Thermocouple Temperature Input Module

* Support Thermocouple J.K.T.R.S.E.B.N.C Type

* Protocol MODBUS RTU, ASCII Command

* Support Isolated input channels

* Fully photo-isolation 3750Vrms

* Wide supply voltages (10-30V)

* Built-in TVS / ESD protection

* Burn-out auto detection
Jun-04-12
 
The King Pigeon S220 GPRS RTU Telemetry Data Logger equipped Siemens MC55i quad-band GPRS Module inside, is a low cost, M2M, data logger, universal GSM GPRS Engine which can transmit and receive analog, digital and pulse counter data, PLC, Varity metering equipments to any device connected to the GSM/GPRS network such as mobile phones, Web Sites, monitoring center, control room, SCADA, etc.
Mar-20-20
 
EDAM-8015
6-ch ISO RTD Input module

* Support PT100, PT1000, Balco 500, NI604, NI1000 RTD types

* Protocol MODBUS RTU, ASCII Command

* Support isolated input channels

* Fully photo-isolation 3750Vrms

* Wide supply voltages (10_30V)

* Built-in TVS/ESD protection

* Burn-out auto detection
Mar-20-20
 
EDAM-8018A
8 Isolated Analog/Thermocouple Temperature Input Module

* Support Thermocouple J.K.T.R.S.E.B.N.C Type

* Protocol MODBUS RTU, ASCII Command

* Support Isolated input channels

* Fully photo-isolation 3750Vrms

* Wide supply voltages (10-30V)

* Built-in TVS / ESD protection

* Burn-out auto detection
Mar-18-20
 
6-ch ISO RTD Input module

* Support PT100, PT1000, Balco 500, NI604, NI1000 RTD types

* Protocol MODBUS RTU, ASCII Command

* Support isolated input channels

* Fully photo-isolation 3750Vrms

* Wide supply voltages (10_30V)

* Built-in TVS/ESD protection

* Burn-out auto detection
1013 Modbus Rtu To Fieldbus Ff Built In Module Suppliers
Short on time? Let Modbus Rtu To Fieldbus Ff Built In Module sellers contact you.
Mar-20-20
 
EDAM-5019
16-ch Thermocouple Input Module with 2 iso. DI and 1 DO

* Protocol USB2.0 TCP/IP, MODBUS RTU, MODBUS TCP ASCII Command

* Support USB2.0, 10/100 Ethernet, RS485/232C, CAN (optional)

* Support Thermocouple J, K, T, R, S, E, B, N, C Type

* Support isolated input channels

* Fully photo-isolation 3750Vrms � Wide supply voltages (10_30V)

* Built-in TVS/ESD protection

* Burn-out auto detection
Apr-12-12
Supplier From Shenzhen, Guangdong, China
May-19-18
 
Model:S278
Name: Cellular IoT Modbus Gateway
The Cellular IoT Modbus Gateway is an industrial class, high reliability, high stability, and programmable Remote Terminal Unit (RTU). It embedded 32-Bit High Performance Microprocessor MCU, integrated 1 Industrial 10/100M adaptive Ethernet module inside and inbuilt industrial Cellular module. It provides 4 digital inputs, 2 relay outputs, 1 ambient sensor input for monitoring onsite temperature and humidity, and RS485 serial port, performs as Modbus RTU Master Supports extend maximum 320 mapping registers. It can monitoring and operates the I/O ports by SMS, APP, Web Server, internet, timers and programmed inter-lock events automatically.

The Cellular IoT Modbus Gateway supports transparent data transmission and performs as Modbus Slave over GPRS/3G/4G/NB-IoT network and RS485 serial port. Moreover, the Cellular IoT Modbus RTU can be used as Modbus RTU Master to reading smart meters, I/O modules, PLC, and converts to SMS alert once triggered the threshold value, or transmit data to remote server over GPRS/3G/4G/NB-IOT network.

Main Featuresï¼?
1. Can be operated from anywhere, no distance limitation;

2. Quad band 850/900/1800/1900Mhz GSM GPRS Module inside.

3. 3G/4G/NB-IoT Modules are optional;

4. Modular design, can easily upgrade the cellular module if network upgrade;

5. Embedded ARM® Cortex�-M4 32 Bit RISC Core, 168 MHz inside, RTOS system, reliable performance with in-built watchdog;

6. Wide range power supply 9~36VDC with over voltage and phase-reversal protection;

7. 4 digital inputs, compatibles dry and wet contact, one of it can be used as pulse counter;

8. 2 relay output (5A/30VDC, 5A/250VAC), compatibles pulse outputs;

9. 1 ambient sensor input for monitoring onsite temperature and humidity;

10. Inbuilt inter-lock logic programmer and powerful timer program function;

11. Resend the data while communication failure and alert to users by SMS;

12. Inbuilt TCP/IP protocol stack, supports cloud, APP and web server applications.

13. Supports Modbus TCP protocol, can integrate to SCADA,HMI,DSC directly.

14. Integrated 1 Industrial 10/100M adaptive Ethernet module inside, supports Modbus TCP;

15. 1 RS485 port supports Modbus RTU Master, supports max. 320 mapping registers, can be used to extend I/O ports or meters;

16. Supports SMS Alert when I/O triggered or recovery, and external power lost or recovery;

17. Provides 1 channel 9~36VDC power source output for external device, saving wiring cost;

18. Up to 10 SMS Alert and dial numbers, can program to receive specified alarm message.

19. Inbuilt 4M internal memory to save historical data and events;

20. Inbuilt large capacity automatically rechargeable backup battery;
Aug-14-22

Mios Modular Remote I/o System

$200
MOQ: Not Specified
Supplier From Chongqing, China
 
MIOS system is a special design isolated signal remote I/O system, it linked a local area network designed to connect controllers to remote I/O chassis and replacement of discrete wirings by fieldbus or industrial Ethernet communication.

MIOS supports up to 31 slots with as many as 128 I/O points in each system. If you need more, you can expand your system with Ethernet router, easily support thousands of I/O points in a single system
Power Supply 24VDC�±10%
MWG1 â?¦ 1W, other module â?¦ 3W
Analog input Max 60 channels
Digital input Max 60 channels
Analog output Max 60 channels
Digital input Max 60 channels
Communication (RJ45 port) 10m/100m Protocol Modbus TCP, TCP/IP, http
Modbus TCP(client) Max 6 connections
http (client) Max 2 connections
Communication (Modbus Port) Protocol Modbus RTU
Address ID range 1~254
Insulation Resistor >100M�© / 500V between the input / output
Isolation Strength AC1500v 1min between the input / output
Ambient Temp. / Humi. -40 ~ 85 C / â?¦95% RH
Dimensions 113 X 109 X N mm (N â?¦17.5*32)
Terminal Wiring Screw mounting, AWG #26-12
Comm Interface Mini USB
Standard EN61326-2003
LED Indicator Normally lighting indicates power supplied and working normally, blinking indicates digital communication is under way.
Nov-21-20
 
1.Wide working voltage, support 9-36V DC power supply, with anti-reverse protection design;
2. Built-in industrial grade ARM CortexTM core, high performance, stable and reliable;
3. Quad band 850/900/1800/1900Mhz GSM GPRS Module inside.
4. 3G/4G/NB-IoT Modules are optional;
5. Modular design, can easily upgrade the cellular module if network upgrade;
6.Support 1 channel relay output for restart the devices;
7.Supports 1 channel RJ45 Ethernet port, built-in isolation transformer, up to 2KV electromagnetic isolation;
8.Up to 10 user's phone number to receive alarm and daily report SMS/Call;
9. Support monitoring power supply status and max. 7 network devices monitoring simultaneously;
10. Built-in TCP/IP protocol stack, support transparent transmission and Modbus RTU to Modbus TCP Protocol;
11.Inbuilt large capacity automatically rechargeable backup battery;
12. Industrial class design suitable for long time work applications;
13. Support configure parameters, load profiles and upgrade the firmware via PC;
14. Wall mount or 35mm standard DIN rail Design, convenient installation,
15. Metallic cover, small size, exterior dimension is L70*W88*H30mm.
Nov-01-19
 
MODBUS-RTU master station, comply with MODBUS-RTU protocol
Electrical interface connected with Modbus device supports TTL level
Set MODBUS-RTU slave station via parameters provided by GSD file


Company Information
Microcybers production center is 1700m2, with anti-static ground, ventilating system, air source transporting system, temperature and humility control system and production devices. The production center consists of 4 workshops and 1 professional lab, they are: production workshop, assembly workshop, ageing workshop, maintenance workshop and product lab. There are professional production line, pressure transmitter assembly line, instrument assembly line, control system module assembly line and product testing line. Microcyber has the batch capacity for 10 thousand devices per year.
Mar-20-20
 
13 Channels Isolated Digital Output Module

* 13 Isolated Single-Ended output channels

* Open Collector Output (NPN)

* Programmable Host Watchdog Timer For Host Failure Protection.

* Support MODBUS RTU And ASCII Format
Mar-18-20
 
16-ch Analog Input Module with 2-ch Isolated DI and 1-ch DO

* Protocol USB2.0 TCP/IP, MODBUS RTU, MODBUS TCP ASCII Command

* Support USB2.0, 10/100 Ethernet, RS-485/232C, CAN (optional)

* Fully photo-isolation 3750Vrms

* Wide supply voltages (10~30V)
Mar-20-20
 
EDAM-5017
16-ch Analog Input Module with 2-ch Isolated DI and 1-ch DO

* Protocol USB2.0 TCP/IP, MODBUS RTU, MODBUS TCP ASCII Command

* Support USB2.0, 10/100 Ethernet, RS-485/232C, CAN (optional)

* Fully photo-isolation 3750Vrms

* Wide supply voltages (10~30V)
May-19-18
 
Model:S256

Name: Cellular 5-CH DC Electric Measuring RTU

The Cellular (GSM/GPRS/3G/4G/NB-IoT) DC Electric Measuring RTU is special designed for remote monitoring 5- channel DC electricity power. Measure each channel voltage, current, active power, active energy. When overload or exceed the pre-set value, then it will alert by SMS, Voice call, Cloud, APP, Wechat, Web Server, SCADA, HMI, DSC immediately.

The Cellular DC Electric Measuring RTU is an industrial class, high reliability, high stability, and programmable Remote Terminal Unit (RTU). It embedded 32-Bit High Performance Microprocessor MCU, integrated special measurement chip and inbuilt industrial Cellular module. It provides 4 digital inputs, 2 relay outputs, 1 ambient sensor input for monitoring onsite temperature and humidity.

Main Features:
1. Can be operated from anywhere, no distance limitation;

2. Quad band 850/900/1800/1900Mhz GSM GPRS Module inside.

3. 3G/4G/NB-IoT Modules are optional;

4. Modular design, can easily upgrade the cellular module if network upgrade;

5. Embedded ARM® Cortex�-M4 32 Bit RISC Core, 168 MHz inside, RTOS system, reliable performance with in-built watchdog;

6. Wide range power supply 12~36VDC with over voltage and phase-reversal protection;

7. Measurement range: voltage: 60V, 100V, 260V, 450V, 500V, current 5A, 20A, 50A.

8. Supports 5-Channel DC power: current, voltage, active power, active energy;

9. 4 digital inputs, compatibles dry and wet contact;

10. 2 relay output (5A/30VDC, 5A/250VAC), compatibles pulse outputs;

11. 1 ambient sensor input for monitoring onsite temperature and humidity;

12. Supports phase loss, phase recovery, voltage overload, current overload detection and alarm;

13. Inbuilt inter-lock logic programmer and powerful timer program function;

14. Resend the data while communication failure and alert to users by SMS;

15. Inbuilt TCP/IP protocol stack, supports cloud, APP and web server applications.

16. Supports Modbus TCP protocol, can integrate to SCADA, HMI, DSC directly.

17. Integrated 1 Industrial 10/100M adaptive Ethernet module inside, supports Modbus TCP;

18. Supports SMS Alert when overload, I/O triggered or recovery, and external power lost or recovery;

19. Provides 1 channel 12~36VDC power source output for external device, saving wiring cost;

20. Up to 10 SMS Alert and dial numbers, can program to receive specified alarm message.
Nov-21-13
Supplier From Shenzhen, Guangdong, China
 
1.Lamp head built-in:solar panel+li battery+light control sensor+infrared(pir) sensor
2.Eensor control principle:
Daytime:ight control automatic operate solar panel charge for li battery, light bright close
Night: light control automatic operate solar charge close, light bright in save mode(<2w). When man near 8-10m , infrared sensor control operate light bright at full power when man left, the light will work at save mode again after 30 seconds.


Size:540*320*55mm to 1170*330*140mm
Weight: 5.8kg-17kg
Aug-26-14
Supplier From Kowloon, Hong Kong
 
Platform 300 is built on high performance hardware with 1gbps throughput. It is installed with quad-port fiber module or quad-port copper module, platform 300 brings carrier-class qos features and reliability for middle-sized isp networks.
Solution platform with a fully integrated range of functions
• comprehensive bandwidth management
• subscriber management (provision flexible qos policy rules with ease, monitor and report on subscriber traffic)
• flexible and open system (comprehensive soap-based api)
• visibility of network performance (dpi analysis and layer 7 reporting)
• manageability (centralized management, redundancy and failover)
May-27-08
 
Model: JMY680H
1.Product introduction
JMY680H is a RFID read/write module with an UART/IIC/RS232C serial port. The module has various functions and supports the ISO/IEC14443A&B and ISO15693 and ISO7816 contactless cards. Users operate the module via simple command. The module embedded with SAM slot that operate contact smart card according to ISO7816. The module builds in antenna.
2.Characteristics
PCD model:NXP CL RC632
Working frequency: 13.56MHz
Card supported:Mifare 1K/4K, FM11RF08, Ultra Light, DesFire, Mifare ProX, SR176, SRI512, SRI1K, SRI2K, SRI4K, SRIX4K, T=CL smart cards(both ISO14443A & ISO14443B) , TI TagIt, I.Code SLI, ST LRI and other tags according to ISO15693 and ISO7816 SAM cards (both T=0&T=1)
Anti collision ability:Full function anti collision; be able to process multi-cards; be able to set operate single card only
Auto detecting card:Supported, default OFF
SAM slot:1 slot
SAM baud rate:9600bps/38400bps
ISO7816 PPSS set:supported
EEPROM:512 Bytes
Power supply:DC 5V
Interface:IIC/UART/RS232C (select when place order)
Communication rate:IIC:400Kbps
UART: 19.2Kbps/115.2Kbps
Max. command length:254 Bytes
Interface level:UART/IIC: 3.3V (TTL level; 5V tolerance)
Power consumption: 150mA
Operating distance:150mm (depending on card)
Dimension:70mm*50mm*16.5mm
Weight:About 120g
ISP:Supported
Operating temperature: -77 ~ +185¡ãF
Storage temperature: -104 ~ +257¡ãF
RoHS:Supported
3.Protocol
There are UART, IIC or RS232C three optional types of interfaces between the host and module. IIC has the advantage of high communication rate and convenient operation. RS232C has long operation distance. Users select the interface according to the special system.
4.Automatic detecting card
The automatic detecting card function supports the ISO14443A and ISO15693. This function supports only one card operation.



Inner package: box (size: 17.5*14*7cm)
Outer package: carton (size: 48*32*24mm)
Weight: 330g
Terms of delivery: dhl, tnt
Delivery time: 5 working days after receive payment.
Apr-26-13
Supplier From Shanghai, China
Dec-31-20
 
The Cellular IoT Gateway provides 1 ambient sensor input for monitoring onsite temperature and humidity,supports dual sim card,with 2 RS485 serial port, supports 320 extend I/O tags via Modbus RTU protocol. It can monitoring and operates the RS485 ports and extend I/O tags by SMS, APP, Web Server, internet.Supports SMS,GPRS,3G,4G Lte Cellular Networks.Compatible Modbus TCP and MQTT IoT Protocols and can intergrate to the KPIIOT IoT Cloud Platform and OPC, SCADA and MES systems to build an industiral IoT Solution.

1. Can be operated from anywhere, no distance limitation;

2. Quad band 850/900/1800/1900Mhz GSM GPRS Module inside.

3. 3G/4G/NB-IoT Modules are optional;

4. Modular design, can easily upgrade the cellular module if network upgrade;

5. Embedded ARM�® Cortexâ?¢-M4 32 Bit RISC Core, 168 MHz inside, RTOS system, reliable performance with in-built watchdog;

6. Wide range power supply 9~36VDC with over voltage and phase-reversal protection;

7. 1 ambient sensor input for monitoring onsite temperature and humidity;

8. Resend the data while communication failure and alert to users by SMS;

9. Inbuilt TCP/IP protocol stack, supports cloud, APP and web server applications.

10. Supports Modbus TCP protocol, can integrate to SCADA,HMI,DSC directly.

11. 2 RS485 port supports Modbus RTU Master and Slave, can be used to extend I/O ports or meters;

12. Supports SMS Alert when I/O triggered or recovery, and external power lost or recovery;

13. Provides 1 channel 9~36VDC power source output for external device, saving wiring cost;

14. Up to 10 SMS Alert and dial numbers, can program to receive specified alarm message.

15. Inbuilt 8G SD card to save up to 100000 historical data and events;

16. Inbuilt large capacity automatically rechargeable backup battery;

17. Industrial class design suitable for long time work applications;

18. using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;

19. L70 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.
1013 Modbus Rtu To Fieldbus Ff Built In Module Suppliers
Short on time? Let Modbus Rtu To Fieldbus Ff Built In Module sellers contact you.
Explore Modbus Rtu To Fieldbus Ff Built In Module related import export discussions