The CE-IJ03 1 element AC current transducer is designed to measure and monitor average RMS AC current, then produce a standard signal such as 4-20mADC, 0-5VDC and so on.
Rated input: 0-500AAC(average RMS current ; TRMS current optional)
This device is designed to monitor AC leakage current, then produce a standard signal such as 4- 20mADC, 0-5VDC and so on. It can be applied to arrester state detection, insulation of some electrical equipments and leakage current detection.
High overload capacity: This device can accept heavy current input which is up to 2000A and work in high voltage environment;
High stability: This device can effectively suppress the interference;
High safety: Great surge protection capacity and 35KV isolation.
Rated input: 0~0.5-100mA AC optional
Output signal: 0-5V;0-20mA;4-20mA optional
Power supply: +12VDC;+15VDC;+24VDC optional
Accuracy: 1%
Output ripple: 2kohm; Current Outputâ?¤250ohm
Temperature drift: â?¤400/ppm
Response time: â?¤300ms
Operating temperature: -20~+70
Quiescent power consumption: 360mW(with +12VDC power)
Get the motion status( including linear acceleration, high/low frequency, etc.) through Measuring the acceleration, can be applied in different media(ultra-temperature, low temperature, intense radiation environment etc.)
Weight:0.8-110g
Measuring Range:500-10000g
Temperature:-200 to 649ºC
(Hz) Frequency Response: 1-10000
(Pc/g)Senbility:0.75-200
Vibration transducer works based on the piezo effect of the piezoelectric materials. Current product can stand 482°C, used on aircraft engine health analysis system.
Meanwhile, our products are widely used in different industries.
1. Piezoelectric Vibration Sensor
Operating Temperature: -200ºC~649ºC
Measuring Range:500g
Frequency Response:10Hz~2500Hz
2.Application:
1) Aircraft, Engine and other industries facility
2) Aircraft engine health analysis system
3) Vibration Monitoring(such as gas turbine and auxiliary power system,etc.)
4) Vibration Tester: Manually vibration monitoring instrument
Function & Feature
1. Isolate the DC input signal from the DC Output signal, which is directly proportional to the input signal.
2. These isolators can be used to prevent earth loops, which occur when a measuring source
3. Excellent temperature characteristic and good working stability.
4. It have an advantage over loop powered units, in that if for any reason the output lead should become
disconnected, the input will not be saturated.
5. Fixed in a standard 35mm DIN rail or screwed on the cabinet.
4705 Current Transducer Hall Effect Sensor Suppliers
Short on time? Let Current Transducer Hall Effect Sensor sellers contact you.
Function & Feature
1. Isolate the DC input signal from the DC Output signal, which is directly proportional to the input signal.
2. These isolators can be used to prevent earth loops, which occur when a measuring source
3. Excellent temperature characteristic and good working stability.
4. It have an advantage over loop powered units, in that if for any reason the output lead should become
disconnected, the input will not be saturated.
5. Fixed in a standard 35mm DIN rail or screwed on the cabinet.
Function & Feature
1. Have microcontroller technology as the core, using the latest algorithms, to achieve precise
measurement.
2. Current transducer converts an ac current input into a load independent output signal.
3. Excellent temperature characteristic and good working stability.
4. The output signal is based on the a root mean square(rms) measurement of the input signal and hence
the transducer can be used with distorted waveforms.
5. The unit conforms to IEC 60688. In an addition it meets the insulation requirements of IEC 60255-5,
clauses 5, 6 and 8 as well as the high frequency disturbance test of IEC 60255-22 for Class III test
voltage.
Specifications
Inputs:
System current 1A, 5A, 10A, 30A
Absorbed power 0.3VA
Frequency range 50Hz, 60Hz
Output:
Standard nominal outputs 4~20mA, 0-5V,
(others on request) 0-20mA,
5-10V
0-10V
Ripple
Linear hall sensor ah3509
Hall sensor
Hall switch
features
Rated working voltage 4.5 v ~ 6 v,
Operating temperature range: -40 ~ 125;
Rail to rail voltage output, rated output current : 6 ma
,
Variety of package forms and outer packings for your choice.
No mechanical contact, no spark, switch signal stability, no shaking moment, high reliability and safety;
Products meet the eu rohs instruction 2011/65 / eu and reach regulations 1907/2006 / eu requirements
Outline
The sensor will pass linear area /nonlinear area/ saturation area during the magnetic induction increases. When there is no magnetic field that applies in sensor (b=0), when the output voltage of sensor is only half of vcc (vcc/2); when n pole faces mark surface of sensor, and be closed to it gradualy (b-, the output voltage begins to decrease, and the voltage doesnt reduce with the increased magnetic field; when the s pole of magnet faces the mark surface of the sensor and is closed to sensor gradualy b+, the output voltage of sensor begins to increase, and it doesnt increase with the increased magnetic field after it reaches saturation voltage.
Linear hall sensor ah3507
Hall sensor
Hall switch
Features
Rated working voltage 4.5 v ~ 6 v;
Operating temperature range: -40, ~ 125,
Rail to rail voltage output, rated output current : 6 ma;
Variety of package forms and outer packings for your choice;
No mechanical contact, no spark, switch signal stability, no shaking moment, high reliability and safety;
Products meet the eu rohs instruction 2011/65 / eu and reach regulations 1907/2006 / eu requirements.
Ah3507 is a kind of analog signal output hall ic, the output voltage changes with the changes of magnetic field. The sensor chip has built-in reverse voltage protection, voltage regulators, temperature compensation circuit, hall-voltage generator, signal amplifier, and other circuit unit etc. Excellent voltage regulator and temperature compensation circuit ensure the sensor stab
le operates ove r a wide vo ltage range and temperature range, and the reverse voltage protection circuit avoids the sensor to be damaged by reverse voltage.
Micropowr hall sensor ah3662
Hall sensor
Hall switch
Features
Micropower designing;
Rated supply voltage , 2.4 v ~ 5.5 v;
Omnipolar operating, no , nor , spole in excitation magnetic field, high magnetic sensitivity, highly symmetry in positive and negative magnetic switch point;
Built-in dynamic imbalance voltage compensition circuit, high temperature stability, small temperature drift in switch point, resistant to mechanical stress and thermal stress, the power consumption is only 8, w when the power supply is 2.75v;
Built-in pull-up resistor;
Products meet the eu
Rohs instruction 2011/65 / eu and reach regulations 1907/2006 / eu requirements.
Outline
Ah3662 is a kind of high sensitivity omnipolar micropower hall sensor. The special designing circuit enable the sensor has omnipolar (no , sor , npole) magnetic field excitation function, excellent positive and negative switch symmetry, and bitty average power consumption current. When the magnet (no , sor , npole) is closed to sensor, , , the sensor outputs low level; when the magnet is far away from sensor the sensor outputs high level.
Linear hall sensor ah3509
Hall sensor
Hall switch
features
Rated working voltage 4.5 v ~ 6 v,
Operating temperature range: -40 ~ 125;
Rail to rail voltage output, rated output current : 6 ma
,
Variety of package forms and outer packings for your choice.
No mechanical contact, no spark, switch signal stability, no shaking moment, high reliability and safety;
Products meet the eu rohs instruction 2011/65 / eu and reach regulations 1907/2006 / eu requirements
Outline
The sensor will pass linear area /nonlinear area/ saturation area during the magnetic induction increases. When there is no magnetic field that applies in sensor (b=0), when the output voltage of sensor is only half of vcc (vcc/2); when n pole faces mark surface of sensor, and be closed to it gradualy (b-, the output voltage begins to decrease, and the voltage doesnt reduce with the increased magnetic field; when the s pole of magnet faces the mark surface of the sensor and is closed to sensor gradualy b+, the output voltage of sensor begins to increase, and it doesnt increase with the increased magnetic field after it reaches saturation voltage.
Accu-Chek test strips are essential components of blood glucose monitoring for individuals with diabetes. These strips are designed to work seamlessly with Accu-Chek blood glucose meters, enabling accurate and reliable measurement of blood sugar levels. The strips utilize advanced technology to require only a small blood sample, making the testing process more comfortable. With rapid and precise results, Accu-Chek test strips empower users to effectively manage their diabetes by providing valuable insights into their current glucose levels. This user-friendly and indispensable tool plays a crucial role in facilitating proactive health management for individuals living with diabetes.
Betel nuts, also known as areca nuts, are the seeds of the Areca catechu palm tree. They are commonly chewed in many parts of Asia and the Pacific for their stimulant effects. Here are some key points about betel nuts:
Chewing Tradition: Betel nut chewing is a cultural and social practice that dates back centuries in many Asian and Pacific countries. It is often part of social gatherings, ceremonies, and rituals.
Stimulant Effects: Betel nuts contain arecoline, an alkaloid that has stimulant properties similar to nicotine. Chewing betel nuts can lead to increased alertness, a mild sense of euphoria, and a stimulating effect on the central nervous system.
Preparation and Consumption: Betel nuts are typically prepared by slicing the nut and wrapping it in a betel leaf along with other ingredients like slaked lime (calcium hydroxide) and sometimes tobacco. The package is then chewed, releasing the active compounds. The combination of areca nut, betel leaf, slaked lime, and optional tobacco is referred to as a "betel quid."
Health Concerns: While betel nut chewing can have stimulant effects, it also comes with health risks. Regular and long-term consumption of betel nuts is associated with various negative health outcomes. These include increased risk of oral cancers, gum disease, tooth decay, and other oral health issues. Betel nuts are considered a Group 1 carcinogen by the International Agency for Research on Cancer (IARC).
Cultural Significance: Betel nut chewing has deep cultural and traditional significance in many communities. It has been used as a symbol of hospitality, social bonding, and as a customary offering during ceremonies and celebrations.
Regulation: Some countries have implemented regulations on the sale and consumption of betel nuts due to their health risks. For example, in certain regions, there are warnings on the packaging about the potential health hazards.
Alternatives: Due to the health concerns associated with betel nut chewing, efforts have been made to promote alternatives that offer a similar social and cultural experience without the negative health effects. These alternatives might involve chewing gums or other non-harmful substances.
It's important to note that my information might not be up to date with the very latest developments or changes, so I recommend checking more recent and reliable sources if you need the most current information on this topic.
Function & Feature
1. Isolate the DC input signal from the DC Output signal, which is directly proportional to the input signal.
2. These isolators can be used to prevent earth loops, which occur when a measuring source
3. Excellent temperature characteristic and good working stability.
4. It have an advantage over loop powered units, in that if for any reason the output lead should become
disconnected, the input will not be saturated.
5. Fixed in a standard 35mm DIN rail or screwed on the cabinet.
6. Ultra-thin dimension, suitable for limited space, the control cabinet.
Function & Feature
1. Isolate the DC input signal from the DC Output signal, which is directly proportional to the input signal.
2. These isolators can be used to prevent earth loops, which occur when a measuring source
3. Excellent temperature characteristic and good working stability.
4. It have an advantage over loop powered units, in that if for any reason the output lead should become
disconnected, the input will not be saturated.
5. Fixed in a standard 35mm DIN rail or screwed on the cabinet.
6. Ultra-thin dimension, suitable for limited space, the control cabinet.
On grid / Grid-tied
Rated power: 5000W
No. of MPPT: 2
Strings per MPPT: 1
Phase: Three phase
Warranty: 10 years
Dimension(W/H/D): 500*428*200mm
Net weight: 21kgs
LED display
Protection devices: DC reverse polarity protection, output over current protection, output overvoltage protection-varistor, integrated DC switch, ground fault monitoring, integrated all-pole sensitive leakage current monitoring unit.
The solar inverter takes full account of the needs of end customers, it is used to convert the DC generated by photovoltaic panels into AC and send it to the grid in a three-phase manner. With excellent performance at the same time, use LED as inverter status display, effectively improve product life.
Using DSP digital control, could afford wide grid voltage range, have a full range of protection features; to maximize the benefits at the same time, greatly enhance the reliability of the product.
On grid / Grid-tied
Rated power: 6000W
No. of MPPT: 2
Strings per MPPT: 1
Phase: Three phase
Warranty: 10 years
Dimension(W/H/D): 500*428*200mm
Net weight: 21kgs
LED display
Protection devices: DC reverse polarity protection, output over current protection, output overvoltage protection-varistor, integrated DC switch, ground fault monitoring, integrated all-pole sensitive leakage current monitoring unit.
The solar inverter takes full account of the needs of end customers, it is used to convert the DC generated by photovoltaic panels into AC and send it to the grid in a three-phase manner. With excellent performance at the same time, use LED as inverter status display, effectively improve product life.
Using DSP digital control, could afford wide grid voltage range, have a full range of protection features; to maximize the benefits at the same time, greatly enhance the reliability of the product.
On grid / Grid-tied
Rated power: 15000W
No. of MPPT: 2
Strings per MPPT: 2+1
Phase: Three phase
Warranty: 10 years
Dimension(W/H/D): 500*428*200mm
Net weight: 24.8kgs
LED display
Protection devices: DC reverse polarity protection, output over current protection, output overvoltage protection-varistor, integrated DC switch, ground fault monitoring, integrated all-pole sensitive leakage current monitoring unit.
The solar inverter takes full account of the needs of end customers, it is used to convert the DC generated by photovoltaic panels into AC and send it to the grid in a three-phase manner. With excellent performance at the same time, use LED as inverter status display, effectively improve product life.
Using DSP digital control, could afford wide grid voltage range, have a full range of protection features; to maximize the benefits at the same time, greatly enhance the reliability of the product.
On grid / Grid-tied
Rated power: 12000W
No. of MPPT: 2
Strings per MPPT: 2+1
Phase: Three phase
Warranty: 10 years
Dimension(W/H/D): 500*428*200mm
Net weight: 24.8kgs
LED display
Protection devices: DC reverse polarity protection, output over current protection, output overvoltage protection-varistor, integrated DC switch, ground fault monitoring, integrated all-pole sensitive leakage current monitoring unit.
The solar inverter takes full account of the needs of end customers, it is used to convert the DC generated by photovoltaic panels into AC and send it to the grid in a three-phase manner. With excellent performance at the same time, use LED as inverter status display, effectively improve product life.
Using DSP digital control, could afford wide grid voltage range, have a full range of protection features; to maximize the benefits at the same time, greatly enhance the reliability of the product.
On grid / Grid-tied
Rated power: 10000W
No. of MPPT: 2
Strings per MPPT: 1
Phase: Three phase
Warranty: 10 years
Dimension(W/H/D): 500*428*200mm
Net weight: 23.2kgs
LED display
Protection devices: DC reverse polarity protection, output over current protection, output overvoltage protection-varistor, integrated DC switch, ground fault monitoring, integrated all-pole sensitive leakage current monitoring unit.
The solar inverter takes full account of the needs of end customers, it is used to convert the DC generated by photovoltaic panels into AC and send it to the grid in a three-phase manner. With excellent performance at the same time, use LED as inverter status display, effectively improve product life.
Using DSP digital control, could afford wide grid voltage range, have a full range of protection features; to maximize the benefits at the same time, greatly enhance the reliability of the product.
4705 Current Transducer Hall Effect Sensor Suppliers
Short on time? Let Current Transducer Hall Effect Sensor sellers contact you.