The RT6303-S Three Phase Energy Meter Test Instrument(Split Type) adopts internationally advanced new-generation digital power source technologt,integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way.The Three phase energy meter test instrument¡¯s power source uses MCU single chip microprocessor as its core technology and adopts various techniques as digital synthesis,digital frequency modulation,digital amplitude modulation,digital phase-shifting,pulse width modulation and so on to bring you such important features as high reliability and good load characteristics.Its more humane and intelligent meter calibration software makes it possible for an ordinary,heavy and boring calibration to be carried out more easily and efficiently.
Technical Parameters:
1. Accuracy class: 0.1/0.05
2. Reference standard energy meter: Three phase wide-measurement range standard energy meter,Accuracy class:0.1/0.05
3. Output voltage: 3* 57.7/100/220/380V Y/¡÷,0~120%Adjustment fineness:0.01% full range,adjustable phase by phase
4. Output current: 3* 0.1~100A(200A also available),0~120%Adjustment fineness:0.0001A(minimum),adjustable phase by phase
5. Phase shift:0~360¡ãAdjustment fineness:0.01¡ã,adjustable phase by phase
6. Frequency:45Hz~65Hz,Adjustment fineness:0.01Hz
7. Output waveform distortion:Both voltage and current<0.5%
8. Output voltage,current and power stability:<0.05%(180s)
9. Output capacity(per phase): Current:650VA(120A); Voltage:300VA(16 meter testing positions). If necessary,the maximum load can be extended to Current:1,200VA and Voltage:800VA
10. Load characteristics:Resistive,inductive and capacitive(less than 4uF)
11. Harmonic wave output:2-21st sub-harmonic wave,content<40%; 3rd,5th and 7th sub-harmonic waves are superposed,content<10% each;Control of wave group(sub-harmonic wave)
12. Energy meter testing positions:16/32(standard);3~40 meter testing positions also available
13. Testing functions:Accuracy testing,Creep testing(no load testing),Starting up testing,Harmonic testing,Repeatability testing, Influencing testing,Dial testing and etc.
14. Power supply: AC 3*220/380V¡À10%,50Hz(customer define);Max. power consumption:2000VA(16 meter test positions).
Dimension:
16 meter testing positions(1 rack): 2200*700*1920mm
32 meter testing positions(2 racks): 2200*700*1920mm each
Cabinet: 600*800*1920mm.
Product description
Gf102 single phase energy meter testing set used to test single phase energy meter. Adopt mature signal synthetic and power amplifier technology. High voltage and current output . Widely used in lab and field.
Features
Meter under testing: 1p2w
Testing mode: active power, reactive power
Test 3pcs or 2pcs meter synchronously
Starting test and creeping test
Reference standard and power source integrated, easy to carry.
Measuring mechanical meter and electric meter
Operating by manual keyboard or pc
With shortcut key of normal test point, speed up testing
Internal large capacity storage device for mass memory
Local checking the testing result
Overload, short circuit, open circuit protection
With self-checking function
Technical data
Voltage
Test voltage output (phase-neutral) 0v ¡v 264v
Power of the voltage output Max. 30va , 15va
Resolution 0.01%
Accuracy 0.1% , 0.2%
Stability 0.02%/120s , 0.05%/120s
Distortion factor < 0.3% for linear resistance load
Current
Test current output 1ma ¡v 120a , 1ma ¡v 60a
Power of the current output Max. 100va , 30va
Resolution 0.01%
Accuracy 0.1% , 0.2%
Stability 0.02%/120s
Distortion factor < 0.3% for linear resistance load
Phase angle
Range 0 -- 360¢x
Resolution 0.1¢x
Accuracy 0.2¢x
Frequency
Range 45hz ¡v 65hz
Resolution 0.005hz
Pulse output
High frequency output(ch) 1.666¡ñ105 hz
Low frequency output(cl) 5¡ñ10-5¡ñch
Pulse input
Input channel 3
Input frequency Max. 20hz
Other
Voltage supply 220v¡ó10% 50/60hz¡ó2hz
Ambient temperature -10¢xc -- +40¢xc
Relative humidity 35% -- 85%
Dimensions (w¡ñd¡ñh) (mm) 445¡ñ440¡ñ180 , 410¡ñ220¡ñ150
Weight (kg) 18 , 9.5
Three Phase Energy Meter Field Calibrator is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure various of AC parameters.
Technical index
Electrical parameters
Accuracy class
0.05, 0.1
Resolution
6 TFT 640 480
Electrical parameters - continued
Power supply
220V 10%, 50 60Hz
Li-polymer battery size mm 110 51 16, nominal output voltage 7.2V, capacity 5000mAh
Zero sugar and herbal stimulants, only four calories, 5 hours of energy with no crash
Contains as much caffeine as a cup of the leading premium coffee
Takes just seconds to drink, light and portable, and no refrigeration required
Packed with B vitamins, amino acids and other nutrients, and non-carbonated
The instrument GF312D1 is a precision 0.05% AC energy meter testing instrument, mainly used to test three phase energy meter error on site, measure all various of AC parameters and CT ratio & phase error, it is also as three phase reference energy meter in the laboratory. Mainly using test single phase or three phase meter error on site. GF312D1 energy meter calibrator is an ideal test tool for the metrological service of electricity power company.
7457 Three Phase Portable Energy Meter Tester Suppliers
Short on time? Let Three Phase Portable Energy Meter Tester sellers contact you.
Three Phase Energy Meter Field Calibrator is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure various of AC parameters.
GF112V2 made in GFUVE GROUP, is a high precision single phase handheld energy meter accuracy tester in class 0.1, used for testing all kinds of single phase electronic meters error on site. Wide measurement range from 1mA to 200A and 0 to 600V, frequency range 40.000Hz to 70.000Hz, and also can be used to test alternating current electrical parameters - voltage, current, active power, reactive power, apparent power, harmonics, phase angle, power factor, frequency, energy etc. It can display U & I wave form and vector diagram. Small size, light weight, simple and convenient operation. It is an ideal testing equipment for the metrology departments of electricity power companies and electrical service engineers.
The model GF313 handheld three phase electricity meter field tester is a economical 0.2% AC energy meter accuracy testing device, mainly used to test three phase and single phase electricity energy meter error on site, measure all various of AC electrical parameters - U, I, P, Q, S, PF, F and CT ratio & phase error etc. And then it can check whether the wiring of the electricity meter is correct. GF313 electronic meter tester is an ideal electrical test tool for the metrological service of electricity power utilities.
This type of three-phase electronic energy meter is the active energy metering meter with the data exchange method of numeric medium. The user can load the amount (quantity of electricity) which purchase in advance, make the statement by amount.
This meter is equipped with numeric keyboard interface used to active energy metering and prepayment control. Besides, this meter also have infrared communication, RS485, metering components, real-time-clock device, load controlling switch and other auxiliary equipment.
And it can achieve the function of metering, anti-tamper, G3-PLC power carrier remote meter reading, GPRS meter reading, RF (radio frequency) meter reading, LCD display etc. Meanwhile having energy testing pulse output function and RTC pulse output.
GF312V2 portable three phase multifunction watt-hour meter calibrator on-site is the newest product produced by our company by widely visiting users and referring to the advantages of the same kind of products home and abroad. The measured part of the product adopts high speed A/D transmission to send DSP to conduct digital processing, which largely improves measured degree of accuracy and stability. Central processing part adopts 32-bit ARM embedded technology to make instrument interface novel, function abundant, operation distinct and easy, and performance steady. Class of accuracy: Class 0.02, 0.05 or 0.1, range from 12A/600V or 120A/600V, with comfort design, small size and light weight. The model GF312V2 watt-hour meter calibrator is suit for electric power departments, measuring and quality examining departments and electric lab to field use.
GF312B portable three phase energy meter calibrator with printer is used to calibrate three phase, single phase, active and reactive energy meters error. And it also can be used as voltage, current and power meter to measure AC parameters of three phase power line. It can measure wave distortion factor and 2nd to 64nd harmonic wave. GF312B calibrator is used for grid corporation of measurement and energy test center, metrological service of power supply bureau, national energy measurement of testing authorities.
GF102 series portable single phase energy meter test bench used to test 1pc or 3pcs single phase energy meter or AC meter at same time. Adopt mature signal synthetic and power amplifier technology, high precision voltage source and current source output from 120A/600V. Widely used in lab and field, and then as single phase standard source. It is suite for electricity meter manufacturing enterprises, scientific research institutes, metrological service institutions, electric power companies etc.
GF1021 single phase portable energy meter test system used to test single phase energy meter error. Adopt mature signal synthetic and power amplifier technology, high precision voltage source and current source output. Widely used in lab and field, and then as single phase standard source. The portable meter test equipment offers high functionality combined with an excellent menu guided operation via coloured 7 touch screen or externally via interface.
INTRODUCTION:
The instrument is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure all various of AC parameters.
FEATURES
Three phase active or reactive electricity energy meter.
Calibrate three phase, single phase, and active or reactive meter error.
Measure U(voltage) of three phase or single phase.
Measure I(current) of three phase or single phase.
Measure active power of three phase or single phase.
Measure reactive power of three phase or single phase.
Measure apparent power of three phase or single phase.
Measure power factor of three phase or single phase.
Measure phase angle between voltage and current.
Measure frequency of power line.
Display vector diagram.
Display waveform of U and I.
Analyze and display content of harmonic of U and I.
Measure 2-64 harmonic of U, I.
Store and display measured data.
Optional 5A, 20A, 100A, 500A, 1000A, 2000A, 3000A current clamp.
Measure CT variable ratio.
Measure the ratio or lag-angle of low-voltage transformer.
Adopt 32 bit ARM processor, multi-channel 16 bit precision A/D convertor, high resolution TFT color LCD.
Inner equipped with 0.01% wide-range current transformer and can be equipped with various type current clamps, wide range of measurement and high veracity.
Low consumption circuit design, high energy Lithium battery supply, intellectual power management software, which enables the instrument continuously working up to 10 hours.
The Portable Three Phase kWh Meter test equipment is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single/three phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high precision standard power source.
GF102 series portable single phase energy meter test bench used to test 1pc or 3pcs single phase energy meter or AC meter at same time. Adopt mature signal synthetic and power amplifier technology, high precision voltage source and current source output from 120A/600V. Widely used in lab and field, and then as single phase standard source. It is suite for electricity meter manufacturing enterprises, scientific research institutes, metrological service institutions, electric power companies etc.
The GF302D1S portable three phase energy meter test system consists of an integrated 0.05% three-phase current and voltage source and a three-phase electronic reference standard meter of accuracy class 0.02. Characteristic features of the GF302D1S are its wide measuring range from 0 to 120A and 0 to 600V, high accuracy and high tolerance to unwanted external influences. The GF302D1S allows the monitoring of meter installations as well as analysis of the local mains conditions when it is as portable reference working standard. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7' touch LCD-display. Voltage & current harmonics output from 2 to 63 times. This model portable meter test system can be programmable by PC, automatic generation of energy meter error test report.
On grid / Grid-tied
Rated power: 5000W
No. of MPPT: 2
Strings per MPPT: 1
Phase: Three phase
Warranty: 10 years
Dimension(W/H/D): 500*428*200mm
Net weight: 21kgs
LED display
Protection devices: DC reverse polarity protection, output over current protection, output overvoltage protection-varistor, integrated DC switch, ground fault monitoring, integrated all-pole sensitive leakage current monitoring unit.
The solar inverter takes full account of the needs of end customers, it is used to convert the DC generated by photovoltaic panels into AC and send it to the grid in a three-phase manner. With excellent performance at the same time, use LED as inverter status display, effectively improve product life.
Using DSP digital control, could afford wide grid voltage range, have a full range of protection features; to maximize the benefits at the same time, greatly enhance the reliability of the product.
On grid / Grid-tied
Rated power: 6000W
No. of MPPT: 2
Strings per MPPT: 1
Phase: Three phase
Warranty: 10 years
Dimension(W/H/D): 500*428*200mm
Net weight: 21kgs
LED display
Protection devices: DC reverse polarity protection, output over current protection, output overvoltage protection-varistor, integrated DC switch, ground fault monitoring, integrated all-pole sensitive leakage current monitoring unit.
The solar inverter takes full account of the needs of end customers, it is used to convert the DC generated by photovoltaic panels into AC and send it to the grid in a three-phase manner. With excellent performance at the same time, use LED as inverter status display, effectively improve product life.
Using DSP digital control, could afford wide grid voltage range, have a full range of protection features; to maximize the benefits at the same time, greatly enhance the reliability of the product.
7457 Three Phase Portable Energy Meter Tester Suppliers