Buyer is interested to receive quotations for the following RFQ -
Product Name: Electrical Immersion Heaters
Specifications:
Type: Vulcanic Flanged Immersion Heater
Make: Vulcanic
Quantity: 2 Units Initially, Later Less Than Container Load (LCL)
Standards: Relevant IEC Standards
Electrical Specifications: SP-1103 And SP-1107
Process And Mechanical Specifications: SP-2454
Supply Characteristics: As Per DEP, With Deviations Specified
Allowed Total Harmonic Distortion (THD): 6.5%
Rated Supply Voltage: 415 V Plus Or Minus 5%, 3-Phase, 4-Wire
Rated Frequency: 50 Hz Plus Or Minus 2%
Power Supply: 3 KW
Prospective Short Circuit Current At PC: KA RMS, KA Peak, Or Fuse Protection Rated In A
P&C Assembly Service Conditions: As Per DEP, Specify Separately
Heater Service Conditions: As Per DEP, Specify Separately
Area Classification: Zone 2
Temperature Class: T3
Gas Group: IIB
Incoming Switch In P&C Assembly: Required
Key Interlock: Not Required
Unit Transformer: Not Required
Transformer In Heater Supplier Scope: No
HV Supply: Not Applicable
Transformer Data: Not Applicable
Input Signal: 4 To 20 MA
Transducers For Remote Metering: In The Heater
Suncover: Required
Over-Temperature Control: Via Instrument Interface
Incoming Cable Size: 4C X 16 Sq Mm, M25 Gland
Fuse Type: DIN
Outgoing Cable Size: 2 X 2 X 1.13 Mm
P&C Assembly Space Heater: Required
Space Heater Cable Size: 3C X 4 Sq Mm, M20 Gland
Witnessed Inspection And Testing: Not Required
Cable Entry: From Below
Document Language: English
Equipment Language: English
Cable Gland Plate: Drilled
Cable Glands: Required
Gland Type: 3/4 Inch NPT, Brass Double Compression
Nearest Service Organization: Vulcanic, Torrelavega, Spain
Maximum Power Requirement: 3 KW
P&C Assembly Space Heater Included: Yes
Main Terminal Box Space Heater Included: Yes
Suncover Over Main Terminal Box: Yes
Over-Temperature Devices: PT100
Cooling: Natural
Specified Tender Documentation Attached: No
Detailed Test Protocol Attached: No
Heating Element Material: SS321
Flange Material: SS316
GDD150 Box: SS316L, No
Material Compliance: SP-2337 And SP-2454
Air Flow Capacity: 148 Nm3/Hr
Minimum Inlet Air Temperature: 5°C
Outlet Air Temperature: 54°C
Maximum Air Pressure: 950 KPag
Heater Element Head Outer Diameter: 204 Mm
Heating Element Diameter: 86 Mm
Heating Element Length: 800 Mm
Heating Element Total Length: 1,143 Mm
Heater Shell Outer Diameter: 114.3 Mm (4 Inches)
Heater Shell Total Length: 996 Mm
Heater Shell: Excluded From Scope Of Supply
Bellelli Scope: NPT To Metric Adapters For All Cable Glands
Supply Requirement: Compliance With All Attached Documents
Quotation Requirement: All Deviations And Exceptions Must Be Clearly Identified And Detailed For Evaluation And Approval
Quantity Required : 1 Less than Container Load/LCL
Shipping Terms : DAP
HS Code : 851610
Destination Port : Northern Italy, Italy
Payment Terms : Bank Transfer
Looking for suppliers from : Worldwide
Contact : Mr. Matteo Sartore / Antonio